The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Fabric-Based Wearable Dry Electrodes for Body Surface Biopotential Recording
Abstract
A flexible and conformable dry electrode design on nonwoven fabrics is examined as a sensing platform for biopotential measurements. Due to limitations of commercial wet electrodes (e.g., shelf life, skin irritation), dry electrodes are investigated as the potential candidates for long-term monitoring of ECG signals. Multilayered dry electrodes are fabricated by screen printing of Ag/AgCl conductive inks on flexible nonwoven fabrics. This study focuses on the investigation of skin-electrode interface, form factor design, electrode body placement of printed dry electrodes for a wearable sensing platform. ECG signals obtained with dry and wet electrodes are comparatively studied as a function of body posture and movement. Experimental results show that skin-electrode impedance is influenced by printed electrode area, skin-electrode interface material, and applied pressure. The printed electrode yields comparable ECG signals to wet electrodes, and the QRS peak amplitude of ECG signal is dependent on printed electrode area and electrode on body spacing. Overall, fabric-based printed dry electrodes present an inexpensive health monitoring platform solution for mobile wearable electronics applications by fulfilling user comfort and wearability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043
CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190288 · Cited by 434
A Multiparameter Wearable Physiologic Monitoring System for Space and Terrestrial Applications
Mundt, C. W., Montgomery, K. N., Udoh, U. E., Barker, V. N., Thonier, G. C., Tellier, A. M., Ricks, R. D., Darling, R. B., Cagle, Y. D., Cabrol, N. A., et al. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854509 · Cited by 226
Accuracy of the LifeShirt® (Vivometrics) in the detection of cardiac rhythms
Heilman, K. J., & Porges, S. W. (2007) · Biological Psychology · doi:10.1016/j.biopsycho.2007.04.001 · Cited by 115
Cited by
Application Challenges in Fiber and Textile Electronics
Wang, L., Fu, X., He, J., Shi, X., Chen, T., Chen, P., Wang, B., & Peng, H. (2020) · Advanced Materials · doi:10.1002/adma.201901971 · Cited by 477
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395
Ambulatory cardiac bio-signals: From mirage to clinical reality through a decade of progress
Periyaswamy, T., & Balasubramanian, M. (2019) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.07.007 · Cited by 14
Metadata
- Authors
- Yokus, M. A., & Jur, J. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2016-02
- Volume
- 63
- Issue
- 2
- Pages
- 423-430
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2248796483
- Cited by
- 214
- References
- 4
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.