Simultaneous monitoring of ballistocardiogram and photoplethysmogram using a camera
Open accessAbstract
We present a noncontact method to measure ballistocardiogram (BCG) and photoplethysmogram (PPG) simultaneously using a single camera. The method tracks the motion of facial features to determine displacement BCG, and extracts the corresponding velocity and acceleration BCGs by taking first and second temporal derivatives from the displacement BCG, respectively. The measured BCG waveforms are consistent with those reported in the literature and also with those recorded with an accelerometer-based reference method. The method also tracks PPG based on the reflected light from the same facial region, which makes it possible to track both BCG and PPG with the same optics. We verify the robustness and reproducibility of the noncontact method with a small pilot study with 23 subjects. The presented method is the first demonstration of simultaneous BCG and PPG monitoring without wearing any extra equipment or marker by the subject.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Numerous other studies that stratify results against Fitzpatrick classification identify the same trend: errors in determining heart rate from wearable PPG devices that use primarily green light are increased in individuals with dark skin tones due to high absorption caused by increased amounts of epidermal melanin.
“In addition to these examples, numerous other studies that stratify results against Fitzpatrick classification identify the same trend; errors in determining heartrate from wearable PPG devices that use primarily green light as their source is increased in individuals with dark skin tones due to the high absorption caused by increased amounts of epidermal melanin [42,43,44,45].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [44]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
(1981) · Cited by 11,963 · see citing works
Shi, J., & Tomasi (1994) · Proceedings of IEEE Conference on Computer Vision and Pattern Recognition CVPR-94 · doi:10.1109/cvpr.1994.323794 · Cited by 7,724 · see citing works
Detection and Tracking of Point Features
Tomasi, C. (1991) · Cited by 2,228 · see citing works
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,728 · see citing works
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378 · see citing works
Detecting Pulse from Head Motions in Video
Balakrishnan, G., Durand, F., & Guttag, J. V. (2013) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2013.440 · Cited by 572 · see citing works
Gesche, H., Grosskurth, D., Küchler, G., & Patzak, A. R. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1983-3 · Cited by 472 · see citing works
Starr, I., Rawson, A. J., Schroeder, H. A., & Joseph, N. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.1 · Cited by 398 · see citing works
Remote measurement of cognitive stress via heart rate variability
McDuff, D., Gontarek, S., & Picard, R. W. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944243 · Cited by 315 · see citing works
Fitzpatrick skin typing: applications in dermatology
Sachdeva, S. (2009) · Indian Journal of Dermatology, Venereology and Leprology · doi:10.4103/0378-6323.45238 · Cited by 311 · see citing works
Wieringa, F. P., Mastik, F., & van der Steen, A. F. W. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-5763-2 · Cited by 284 · see citing works
Exploiting Spatial Redundancy of Image Sensor for Motion Robust rPPG
Wang, W., Stuijk, S., & de Haan, G. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2356291 · Cited by 282 · see citing works
Robust ballistocardiogram acquisition for home monitoring
Inan, O. T., Etemadi, M., Wiard, R. M., Giovangrandi, L., & Kovacs, G. T. A. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/2/005 · Cited by 234 · see citing works
Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms
Brüser, C., Stadlthanner, K., de Waele, S., & Leonhardt, S. K. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2128337 · Cited by 219 · see citing works
Noncontact Monitoring Breathing Pattern, Exhalation Flow Rate and Pulse Transit Time
Shao, D., Yang, Y., Liu, C., Tsow, F., Yu, H., & Tao, N. J. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2327024 · Cited by 183 · see citing works
Self-citationTheory and Developments in an Unobtrusive Cardiovascular System Representation: Ballistocardiography
Pinheiro, E., Postolache, O. A., & Girão, P. S. (2010) · The Open Biomedical Engineering Journal · doi:10.2174/1874120701004010201 · Cited by 176 · see citing works
Ballistocardiography — A method worth revisiting
Giovangrandi, L., Inan, O. T., Wiard, R. M., Etemadi, M., & Kovacs, G. T. A. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091062 · Cited by 165 · see citing works
Kim, C., Carek, A. M., Mukkamala, R., Inan, O. T., & Hahn, J. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2440291 · Cited by 155 · see citing works
Noncontact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System
Shao, D., Liu, C., Tsow, F., Yang, Y., Du, Z., Iriya, R., Yu, H., & Tao, N. J. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2481896 · Cited by 151 · see citing works
Self-citationStarr, I., & Schroeder, H. A. (1940) · Journal of Clinical Investigation · doi:10.1172/jci101145 · Cited by 111 · see citing works
An Ear-Worn Vital Signs Monitor
He, D. D., Winokur, E. S., & Sodini, C. G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2459061 · Cited by 109 · see citing works
He, D. D., Winokur, E. S., & Sodini, C. G. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091171 · Cited by 99 · see citing works
Proposals for Ballistocardiographic Nomenclature and Conventions: Revised and Extended
SCARBOROUGH, W. R., Talbot, S. A., Braunstein, J. R., et al. (1956) · Circulation · doi:10.1161/01.cir.14.3.435 · Cited by 94 · see citing works
Non-constrained monitoring of systolic blood pressure on a weighing scale
Shin, J. H., Lee, K. M., & Park, K. S. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/7/011 · Cited by 86 · see citing works
Twenty-Year Studies with the Ballistocardiograph
Starr, I., & Wood, F. C. (1961) · Circulation · doi:10.1161/01.cir.23.5.714 · Cited by 85 · see citing works
Signal to noise ratio and response variability measurements in single trial evoked potentials
Coppola, R., Tabor, R., & Buchsbaum, M. S. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90267-5 · Cited by 82 · see citing works
THE MASS-MOVEMENTS OF THE CIRCULATION AS SHOWN BY A RECOIL CURVE
Henderson, Y. (1905) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1905.14.3.287 · Cited by 74 · see citing works
Ballistocardiographic Artifacts in PPG Imaging
Moço, A., Stuijk, S., & de Haan, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2502398 · Cited by 70 · see citing works
ROI Selection for Remote Photoplethysmography
Lempe, G., Zaunseder, S., Wirthgen, T., Zipser, S., & Malberg, H. (2013) · Informatik aktuell · doi:10.1007/978-3-642-36480-8_19 · Cited by 68 · see citing works
Winokur, E. S., He, D. D., & Sodini, C. G. (2012) · doi:10.1109/embc.2012.6346527 · Cited by 57 · see citing works
Physical basis of the low-frequency ballistocardiograph
Bürger, H., Noordergraaf, A., & Verhagen, A. M. W. (1953) · American Heart Journal · doi:10.1016/0002-8703(53)90241-5 · Cited by 55 · see citing works
Ballistocardiography in sitting and horizontal positions
Alametsä, J., Viik, J., Alakare, J., Värri, A. O., & Palomäki, A. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/9/006 · Cited by 45 · see citing works
Three dimensional ballistocardiography: Methodology and results from microgravity and dry immersion
Migeotte, P., Tank, J., Pattyn, N., Funtova, I. I., Baevsky, R. M., Neyt, X., & Prisk, G. K. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091060 · Cited by 37 · see citing works
Chen, Z., Yang, X., Teo, J. T., & Ng, S. H. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610029 · Cited by 35 · see citing works
HRV analysis and blood pressure monitoring on weighing scale using BCG
Shin, J. H., & Park, K. S. (2012) · doi:10.1109/embc.2012.6346792 · Cited by 35 · see citing works
SCARBOROUGH, W. R., Folk, E. F., Smith, P. M., et al. (1958) · The American Journal of Cardiology · doi:10.1016/0002-9149(58)90188-7 · Cited by 34 · see citing works
Thompson, W. B., Rappaport, M. B., & Sprague, H. B. (1953) · Circulation · doi:10.1161/01.cir.7.3.321 · Cited by 33 · see citing works
Acceleration Ballistocardiography
ELLIOTT, R. V., PACKARD, R. G., & Kyrazis, D. T. (1954) · Circulation · doi:10.1161/01.cir.9.2.281 · Cited by 32 · see citing works
ESSAY ON THE BALLISTOCARDIOGRAM
Starr, I. (1954) · JAMA · doi:10.1001/jama.1954.73690340011009 · Cited by 29 · see citing works
Comparative analysis of seismocardiogram waves with the ultra-low frequency ballistocardiogram
Ngai, B., Tavakolian, K., Akhbardeh, A., Blaber, A. P., Kamińska, B., & Noordergraaf, A. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333649 · Cited by 25 · see citing works
Progress Towards a Physiological Cardiology
Starr, I. (1965) · Annals of Internal Medicine · doi:10.7326/0003-4819-63-6-1079 · Cited by 18 · see citing works
The potential of EMFi sensors in heart activity monitoring
Alametsä, J., Värri, A. O., Koivuluoma, M., et al. (2004) · Cited by 18 · see citing works
Normal Standards for Amplitude of Ballistocardiograms Calibrated by Force
Starr, I. (1955) · Circulation · doi:10.1161/01.cir.11.6.914 · Cited by 15 · see citing works
Ballistocardiography: past, present and future.
Wj, G. (1979) · PubMed · Cited by 10 · see citing works
On reading ballistocardiograms∗
Starr, I. (1958) · The American Journal of Cardiology · doi:10.1016/0002-9149(58)90326-6 · Cited by 9 · see citing works
van Brummelen, A. G. W., SCARBOROUGH, W. R., & Josenhans, W. K. T. (1964) · American Heart Journal · doi:10.1016/0002-8703(64)90011-0 · Cited by 7 · see citing works
He, D. D. (2013) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 5 · see citing works
Dh, J., Eddleman, E. E., Wh, B., et al. (1971) · PubMed · Cited by 4 · see citing works
Optical ballistocardiography for gating and patient monitoring during MRI: an initial study
Krug, J., Lüsebrink, F., Speck, O., et al. (2014) · Cited by 3 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- [36]Kim CS Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring IEEE Trans Biomed Eng 62 11 2657 2664 11 2015 26054058 PMC4626385
Cited by
Sorted by citations
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Nowara, E. M., McDuff, D., & Veeraraghavan, A. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw50498.2020.00150 · Cited by 66 · see citing works
Addison, P. S., Jacquel, D., Foo, D. M. H., & Borg, U. R. (2018) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-017-0076-1 · Cited by 24 · see citing works
- Authors
- Shao, D., Tsow, F., Liu, C., Yang, Y., & Tao, N.
- Affiliations
- Arizona State University (US)
- Nanjing University (CN)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2017-05
- Volume
- 64
- Issue
- 5
- Pages
- 1003-1010
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- PMC
- PMC5523454
- OpenAlex
- W2461101863
- Cited by
- 69
- References
- 50
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 5 · 2023: 8 · 2022: 8 · 2021: 15 · 2020: 16 · 2019: 4 · 2018: 5 · 2017: 2 · 2016: 2
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Natural Science Foundation of China (21327902)
- National Institute of Biomedical Imaging and Bioengineering (1U01EB021980)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- ballistocardiography, photoplethysmogram, camera-based measurement, facial feature tracking, reflected light
- MeSH terms
- Algorithms, Ballistocardiography, Blood Volume, Face, Heart, Humans, Image Interpretation, Computer-Assisted, Pattern Recognition, Automated, Photography, Sensitivity and Specificity, Video Recording, Reproducibility of Results, Photoplethysmography, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review