Cited by 69Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlECG Monitoring and Analysis

Simultaneous monitoring of ballistocardiogram and photoplethysmogram using a camera

Open access
Shao, Dangdang, Tsow, Francis, Liu, Chenbin, Yang, Yuting, Tao, Nongjian·2017·IEEE Transactions on Biomedical Engineering

Abstract

We present a noncontact method to measure ballistocardiogram (BCG) and photoplethysmogram (PPG) simultaneously using a single camera. The method tracks the motion of facial features to determine displacement BCG, and extracts the corresponding velocity and acceleration BCGs by taking first and second temporal derivatives from the displacement BCG, respectively. The measured BCG waveforms are consistent with those reported in the literature and also with those recorded with an accelerometer-based reference method. The method also tracks PPG based on the reflected light from the same facial region, which makes it possible to track both BCG and PPG with the same optics. We verify the robustness and reproducibility of the noncontact method with a small pilot study with 23 subjects. The presented method is the first demonstration of simultaneous BCG and PPG monitoring without wearing any extra equipment or marker by the subject.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2016.2585109

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Numerous other studies that stratify results against Fitzpatrick classification identify the same trend: errors in determining heart rate from wearable PPG devices that use primarily green light are increased in individuals with dark skin tones due to high absorption caused by increased amounts of epidermal melanin.

    “In addition to these examples, numerous other studies that stratify results against Fitzpatrick classification identify the same trend; errors in determining heartrate from wearable PPG devices that use primarily green light as their source is increased in individuals with dark skin tones due to the high absorption caused by increased amounts of epidermal melanin [42,43,44,45].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [36]Kim CS Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring IEEE Trans Biomed Eng 62 11 2657 2664 11 2015 26054058 PMC4626385

Cited by

Sorted by citations

Authors
Shao, D., Tsow, F., Liu, C., Yang, Y., & Tao, N.
Affiliations
  • Arizona State University (US)
  • Nanjing University (CN)
Venue
IEEE Transactions on Biomedical Engineering
Published
2017-05
Volume
64
Issue
5
Pages
1003-1010
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2461101863
Cited by
69
References
50
Citations by year
2026: 2 · 2025: 2 · 2024: 5 · 2023: 8 · 2022: 8 · 2021: 15 · 2020: 16 · 2019: 4 · 2018: 5 · 2017: 2 · 2016: 2
FWCI
2.09
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Natural Science Foundation of China (21327902)
  • National Institute of Biomedical Imaging and Bioengineering (1U01EB021980)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
ballistocardiography, photoplethysmogram, camera-based measurement, facial feature tracking, reflected light
MeSH terms
Algorithms, Ballistocardiography, Blood Volume, Face, Heart, Humans, Image Interpretation, Computer-Assisted, Pattern Recognition, Automated, Photography, Sensitivity and Specificity, Video Recording, Reproducibility of Results, Photoplethysmography, Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review