Abstract
GOAL: During mechanical ventilation, patient-ventilator disharmony is frequently observed and may result in increased breathing effort, compromising the patient's comfort and recovery. This circumstance requires clinical intervention and becomes challenging when verbal communication is difficult. In this study, we propose a brain-computer interface (BCI) to automatically and noninvasively detect patient-ventilator disharmony from electroencephalographic (EEG) signals: a brain-ventilator interface (BVI). METHODS: Our framework exploits the cortical activation provoked by the inspiratory compensation when the subject and the ventilator are desynchronized. Use of a one-class approach and Riemannian geometry of EEG covariance matrices allows effective classification of respiratory states. The BVI is validated on nine healthy subjects that performed different respiratory tasks that mimic a patient-ventilator disharmony. RESULTS: Classification performances, in terms of areas under receiver operating characteristic curves, are significantly improved using EEG signals compared to detection based on air flow. Reduction in the number of electrodes that can achieve discrimination can be often desirable (e.g., for portable BCI systems). By using an iterative channel selection technique, the common highest order ranking, we find that a reduced set of electrodes (n = 6) can slightly improve for an intrasubject configuration, and it still provides fairly good performances for a general intersubject setting. CONCLUSION: Results support the discriminant capacity of our approach to identify anomalous respiratory states, by learning from a training set containing only normal respiratory epochs. SIGNIFICANCE: The proposed framework opens the door to BVIs for monitoring patient's breathing comfort and adapting ventilator parameters to patient respiratory needs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Optimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 3×
“A standard procedure to extract features in EEG epoched data ( X i ) by CSP consists of computation of the log-variances of projected X i on the spatial filters [28].”
MethodInfluentialRiemannian center of mass and mollifier smoothing
Karcher, H. (1977) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.3160300502 · Cited by 995
Lotte, F. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2404941 · Cited by 327 · cited 1×
“The use of regularization or adaptive learning approaches (see [45] and references”
Method
Cited by
ERS statement on respiratory muscle testing at rest and during exercise
Laveneziana, P., Albuquerque, A., Aliverti, A., Babb, T., Barreiro, E., Dres, M., Dubé, B.-P., Fauroux, B., Gea, J., Guenette, J. A., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01214-2018 · Cited by 818
Self-citationA review on transfer learning in EEG signal analysis
Wan, Z., Yang, R., Huang, M., Zeng, N., & Liu, X. (2021) · Neurocomputing · doi:10.1016/j.neucom.2020.09.017 · Cited by 468
Riemannian geometry for EEG-based brain-computer interfaces; a primer and a review
Congedo, M., Barachant, A., & Bhatia, R. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1297192 · Cited by 456
Riemannian Approaches in Brain-Computer Interfaces: A Review
Yger, F., Berar, M., & Lotte, F. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2627016 · Cited by 420
A State-of-the-Art Review of EEG-Based Imagined Speech Decoding
Lopez-Bernal, D., Balderas, D., Ponce, P., & Molina, A. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.867281 · Cited by 107
“It has been successfully applied toward several applications, such as motor imagery, sleep/respiratory states classification, EEG decoding, etc. (Barachant et al., 2010, 2011; Navarro-Sune et al., 2016; Yger et al., 2016; Chu et al., 2020).”
Method
Metadata
- Authors
- Navarro-Sune, X., Hudson, A. L., Fallani, F. D. V., Martinerie, J., Witon, A., Pouget, P., Raux, M., Similowski, T., & Chavez, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2017-05
- Volume
- 64
- Issue
- 5
- Pages
- 1138-1148
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2233001524
- Cited by
- 41
- References
- 5
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.