Wavelet-Based Sit-To-Stand Detection and Assessment of Fall Risk in Older People Using a Wearable Pendant Device
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
GOAL: Wearable devices provide new ways to identify people who are at risk of falls and track long-term changes of mobility in daily life of older people. The aim of this study was to develop a wavelet-based algorithm to detect and assess quality of sit-to-stand movements with a wearable pendant device. METHODS: The algorithm used wavelet transformations of the accelerometer and barometric air pressure sensor data. Detection accuracy was tested in 25 older people performing 30 min of typical daily activities. The ability to differentiate between people who are at risk of falls from people who are not at risk was investigated by assessing group differences of sensor-based sit-to-stand measurements in 34 fallers and 60 nonfallers (based on 12-month fall history) performing sit-to-stand movements as part of a laboratory study. RESULTS: Sit-to-stand movements were detected with 93.1% sensitivity and a false positive rate of 2.9% during activities of daily living. In the laboratory study, fallers had significantly lower maximum acceleration, velocity, and power during the sit-to-stand movement compared to nonfallers. CONCLUSION: The new wavelet-based algorithm accurately detected sit-to-stand movements in older people and differed significantly between older fallers and nonfallers. SIGNIFICANCE: Accurate detection and quantification of sit-to-stand movements may provide objective assessment and monitoring of fall risk during daily life in older people.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interventions for preventing falls in older people living in the community
Gillespie, L. D., Robertson, M. C., Gillespie, W. J., Sherrington, C., Gates, S., Clemson, L., & Lamb, S. E. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007146.pub3 · Cited by 3,966
Muscle weakness and falls in older adults: a systematic review and meta-analysis
Moreland, J. D., Richardson, J. A., Goldsmith, C. H., & Clase, C. M. (2004) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2004.52310.x · Cited by 988 · cited 1×
“Falls are associated with a variety of physical risk factors, including muscle weakness [4]–[6].”
Barometric Pressure and Triaxial Accelerometry-Based Falls Event Detection
Bianchi, F., Redmond, S. J., Narayanan, M. R., Cerutti, S., & Lovell, N. H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2070807 · Cited by 296
Self-citationAmbulatory monitoring of physical activities in patients with Parkinson’s disease
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Burkhard, P. R., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.896591 · Cited by 217
Research works printed but not linked: 33
- 10.1111/j.1532-5415.2005.53455.x · DOI · Paper page
- 10.1002/1099-1166(200011)15:11<1021::AID-GPS234>3.0.CO;2-6 · DOI · Paper page
- 10.1016/0022-3956(75)90026-6 · DOI · Paper page
- 10.1186/1471-2318-14-91 · DOI
- 10.1093/geronj/49.2.M85 · DOI · Paper page
- 10.1159/000381804 · doi:10.1159/000381804
- 10.1109/TBME.2015.2464689 · DOI
- 10.3390/s140508705 · DOI
- 10.1007/s11517-015-1357-9 · DOI
- 10.1080/07370024.2015.1085309 · DOI
- 10.1093/gerona/glv049 · DOI
- 10.1109/TBME.2002.800763 · DOI · Paper page
- 10.1109/TBME.2003.812189 · DOI · Paper page
- 10.1016/j.medengphy.2011.05.002 · DOI · Paper page
- 10.1109/TNSRE.2012.2202691 · DOI
- 10.1109/EMBC.2014.6943965 · DOI
- massé, 0, Detection of postural transitions using trunk-worn inertial and barometric pressure sensor: Application to stroke patients, Proc 13th Int Symp 3D Anal Human Movement, 10
- 10.1109/ISWC.1998.729537 · DOI · Paper page
- 10.1186/1743-0003-10-91 · DOI · Paper page
- 10.1137/0515056 · DOI · Paper page
- lord, 2001, Falls in older people Risk factors and strategies for prevention
- 10.1093/geronj/44.4.M112 · DOI · Paper page
- 10.1017/S1041610210001067 · DOI · Paper page
- 10.1007/BF03325265 · DOI · Paper page
- 10.1111/j.1532-5415.2008.01777.x · DOI · Paper page
- 10.1097/MCO.0000000000000081 · doi:10.1097/mco.0000000000000081
- 10.1111/j.1532-5415.1991.tb01616.x · DOI · Paper page
- 10.1109/IEMBS.2007.4352683 · DOI
- 10.1016/j.gaitpost.2009.11.003 · DOI
- 10.1109/EMBC.2014.6945053 · DOI
- 10.1109/TNSRE.2014.2331895 · DOI
- 10.1016/j.gaitpost.2014.03.193 · DOI
- 10.1109/IEMBS.2010.5626100 · DOI
Cited by
Huynh-The, T., Hua, C.-H., Tu, N. A., & Kim, D.-S. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.3013272 · Cited by 72
“…recognition plays an important function in several healthcare services and applications [6], for instance, from daily living assistance promoting healthy behavior changes [7] to professional medical analysis conducting early risk attention (e.g., fall detection [8] and heart failure detection [9]).”
BackgroundAboye, G. T., Vande Walle, M., Simegn, G. L., & Aerts, J.-M. (2023) · Digital Health · doi:10.1177/20552076231180972 · Cited by 31
Hsu, Y.-C., Wang, H., Zhao, Y., Chen, F., & Tsui, K.-L. (2021) · Journal of Medical Internet Research · doi:10.2196/30135 · Cited by 9
Metadata
- Authors
- Ejupi, A., Brodie, M., Lord, S. R., Annegarn, J., Redmond, S. J., & Delbaere, K.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2017-07
- Volume
- 64
- Issue
- 7
- Pages
- 1602-1607
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2529025236
- Cited by
- 72
- References
- 4
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- green
- Funders
- EU-funded (#287361)
- iStoppFalls
- Australian National Health and Medical Research Council (NHMRC) EU (#1038210)
- Australian Research Council's Discovery (#DP130102392)
- NHMRC
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.