CoChat

ECG-Based Classification of Resuscitation Cardiac Rhythms for Retrospective Data Analysis

Rad, Ali Bahrami, Eftestol, Trygve, Engan, Kjersti, Irusta, Unai, Kvaloy, Jan Terje, Kramer-Johansen, Jo, Wik, Lars, Katsaggelos, Aggelos K. · 2017 · IEEE Transactions on Biomedical Engineering
Cited by 84

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: There is a need to monitor the heart rhythm in resuscitation to improve treatment quality. Resuscitation rhythms are categorized into: ventricular tachycardia (VT), ventricular fibrillation (VF), pulseless electrical activity (PEA), asystole (AS), and pulse-generating rhythm (PR). Manual annotation of rhythms is time-consuming and infeasible for large datasets. Our objective was to develop ECG-based algorithms for the retrospective and automatic classification of resuscitation cardiac rhythms. METHODS: The dataset consisted of 1631 3-s ECG segments with clinical rhythm annotations, obtained from 298 out-of-hospital cardiac arrest patients. In total, 47 wavelet- and time-domain-based features were computed from the ECG. Features were selected using a wrapper-based feature selection architecture. Classifiers based on Bayesian decision theory, k-nearest neighbor, k-local hyperplane distance nearest neighbor, artificial neural network (ANN), and ensemble of decision trees were studied. RESULTS: The best results were obtained for ANN classifier with Bayesian regularization backpropagation training algorithm with 14 features, which forms the proposed algorithm. The overall accuracy for the proposed algorithm was 78.5%. The sensitivities (and positive-predictive-values) for AS, PEA, PR, VF, and VT were 88.7% (91.0%), 68.9% (70.4%), 65.9% (69.0%), 86.2% (83.8%), and 78.8% (72.9%), respectively. CONCLUSIONS: The results demonstrate that it is possible to classify resuscitation cardiac rhythms automatically, but the accuracy for the organized rhythms (PEA and PR) is low. SIGNIFICANCE: We have made an important step toward making classification of resuscitation rhythms more efficient in the sense of minimal feedback from human experts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2017.2688380

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 84

Metadata

Authors
Rad, A. B., Eftestol, T., Engan, K., Irusta, U., Kvaloy, J. T., Kramer-Johansen, J., Wik, L., & Katsaggelos, A. K.
Venue
IEEE Transactions on Biomedical Engineering
Published
2017-10
Volume
64
Issue
10
Pages
2411-2418
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2604017450
Cited by
84
References
2
FWCI
7.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ECG-Based Classification of Resuscitation Cardiac Rhythms for Retrospective Data Analysis. https://app.cochat.ai/papers/10.1109/tbme.2017.2688380
The paper
Rad, A. B., Eftestol, T., Engan, K., Irusta, U., Kvaloy, J. T., Kramer-Johansen, J., Wik, L., & Katsaggelos, A. K. (2017). ECG-Based Classification of Resuscitation Cardiac Rhythms for Retrospective Data Analysis. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2017.2688380

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.