PARHELIA: Particle Filter-Based Heart Rate Estimation From Photoplethysmographic Signals During Physical Exercise
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The photoplethysmographic (PPG) signal is an important source of information for estimating heart rate (HR). However, the PPG signal could be strongly contaminated by the motion artifact of the subjects, making HR estimation a particularly difficult problem. In this paper, we propose PARHELIA, a PARticle filter-based algorithm for HEart rate estimation using photopLethysmographIc signAls. The proposed method employs a particle filter, and utilizes the simultaneously recorded acceleration signals from a wrist-type sensor, to keep track of multiple HR candidates. This achieves quick recovery from incorrect HR estimations under the strong influence of the MA. Experimental results for a dataset of 12 subjects recorded during fast running showed that the average absolute estimation error was 1.17 beats per minute (BPM) whereas that of the best-known conventional method, JOSS, is 1.28 BPM. Furthermore, the estimation time of PARHELIA is 20 times shorter than JOSS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Zhang, Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406332 · Cited by 388 · cited 7×
“However, it can be replaced by other spectrum analysis methods, such as the one proposed in [13].”
BackgroundResultInfluential
Cited by
Motion artifact cancellation in wearable photoplethysmography using gyroscope
Lee, H., Chung, H., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2879970 · Cited by 79
Paliakaitė, B., Petrėnas, A., Sološenko, A., & Marozas, V. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102421 · Cited by 24
Lee, H., Chung, H., Kim, J.-W., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2894640 · Cited by 22
“Indeed, several MA removal algorithms using acceleration signals provide accurate HR estimation results with a mean absolute error (MAE) of approximately 2 beats per minute (bpm) [6], [17]–[22].”
BackgroundMethodInfluential
Metadata
- Authors
- Fujita, Y., Hiromoto, M., & Sato, T.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2018-01
- Volume
- 65
- Issue
- 1
- Pages
- 189-198
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2609904211
- Cited by
- 53
- References
- 2
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.