Motion artifact identification and removal from wearable reflectance photoplethysmography using piezoelectric transducer
Abstract
Accurate heart rate estimation from reflectance photoplethysmography (PPG) during intense physical activity is difficult given unpredictable motion artifacts (MAs). Recent research has focused on the removal of MAs in PPG signals by considering acceleration signals as noise references. However, this approach does not always effectively remove MAs, as they can be associated with other noise sources. For instance, finger or hand motion reflects upon the wrist, corrupting the PPG signals, but an accelerometer cannot capture this type of MA. Hence, we propose adding a piezoelectric transducer on the wrist to identify noise originated from finger and hand motion. We first detail the developed wearable device that simultaneously measures PPG, acceleration, and piezoelectric pressure signals from the wrist. Then, the effectiveness of piezoelectric pressure signals for MA removal is verified from PPG signals collected under finger tapping and hand folding/unfolding, and from data of 17 healthy subjects undergoing physical activity. MA removal using both acceleration and piezoelectric pressure signals exhibits a mean absolute error of 1.58 beats per minute (bpm), considerably below the error of 3.75 bpm obtained using only acceleration signals. Therefore, measuring piezoelectric pressure signals on the wrist can improve heart rate estimation by providing more information of MAs corrupting PPG signals.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Secondary sensors can be integrated into PPG sensors to detect motion, including accelerometers, gyroscopes, piezoelectric transducers, or another wavelength of light as a motion reference.
“As implemented by consumer-grade HR monitors, secondary sensors can also be integrated into PPG sensors to detect motion. These include accelerometers [175,176,177,178,179], gyroscopes [179,180], piezoelectric transducers [181], or the utilization of another wavelength of light as a motion reference [182,183].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [181]
Both the piezoelectric transducer and another wavelength of light can pick up finer motions such as finger tapping.
“Both the piezoelectric transducer and another wavelength of light can pick up these finer motions [181,182].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [181]
Cites
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775 · cited 1× · see citing works
“This range covers the plausible HR of subjects of any age during both rest and intense physical activity [40], [41].”
BackgroundMoore, K. L., Dalley, A. F., & Agur, A. M. R. (1985) · Andalas University Repository (Andalas University) · Cited by 2,236 · see citing works
Heart-Rate Profile during Exercise as a Predictor of Sudden Death
Jouven, X., Empana, J. P., Schwartz, P. J., Desnos, M., Courbon, D., & Ducimetière, P. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043012 · Cited by 1,008 · see citing works
Dağdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987 · see citing works
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861 · see citing works
Zhang, Z., Pi, Z., & Liu, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2359372 · Cited by 759 · see citing works
ECG beat detection using filter banks
Afonso, V. X., Tompkins, W. J., Nguyen, T. Q., & Luo, S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740882 · Cited by 729 · see citing works
Rayapati, J. S., & Mathur, A. B. (2013) · Cited by 722 · see citing works
Nishime, E. O. (2000) · JAMA · doi:10.1001/jama.284.11.1392 · Cited by 713 · see citing works
Longitudinal Modeling of the Relationship between Age and Maximal Heart Rate
GELLISH, R. L., GOSLIN, B. R., OLSON, R. E., McDONALD, A., RUSSI, G. D., & MOUDGIL, V. K. (2007) · Medicine & Science in Sports & Exercise · doi:10.1097/mss.0b013e31803349c6 · Cited by 660 · cited 1× · see citing works
“This range covers the plausible HR of subjects of any age during both rest and intense physical activity [40], [41].”
BackgroundMichael, S., Graham, K. S., & Davis, G. M. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00301 · Cited by 626 · see citing works
Accurate Heart Rate Monitoring During Physical Exercises Using PPG
Temko, A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2676243 · Cited by 295 · see citing works
Shin, K., Lee, J. S., & Jang, J. (2016) · Nano Energy · doi:10.1016/j.nanoen.2016.02.012 · Cited by 239 · see citing works
Self-citationBioSig: The Free and Open Source Software Library for Biomedical Signal Processing
Vidaurre, C., Sander, T. H., & Schlögl, A. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/935364 · Cited by 220 · see citing works
Salehizadeh, S. M. A., Dao, D. K., Bolkhovsky, J., Cho, C. H., Mendelson, Y., & Chon, K. H. (2015) · Sensors · doi:10.3390/s16010010 · Cited by 173 · see citing works
Yip, M., Jin, R., Nakajima, H. H., Stanković, K. M., & Chandrakasan, A. P. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2355822 · Cited by 146 · see citing works
Mashhadi, M. B., Asadi, E., Eskandari, M., Kiani, S., & Marvasti, F. (2015) · IEEE Signal Processing Letters · doi:10.1109/lsp.2015.2509868 · Cited by 144 · see citing works
Flexible and Surface-Mountable Piezoelectric Sensor Arrays for Underwater Sensing in Marine Vehicles
Asadnia, M., Kottapalli, A. G. P., Shen, Z., Miao, J., & Triantafyllou, M. S. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2259227 · Cited by 120 · see citing works
Jarchi, D., & Casson, A. J. (2016) · Data · doi:10.3390/data2010001 · Cited by 120 · see citing works
Sun, B., & Zhang, Z. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2473697 · Cited by 115 · see citing works
Wearable Sensing of In-Ear Pressure for Heart Rate Monitoring with a Piezoelectric Sensor
Park, J.-H., Jang, D.-G., Park, J., & Youm, S. (2015) · Sensors · doi:10.3390/s150923402 · Cited by 105 · see citing works
Chowdhury, S. S., Hyder, R., Hafiz, M. S. B., & Haque, M. A. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2632201 · Cited by 102 · see citing works
Shu, Y., Li, C., Wang, Z., Mi, W., Li, Y., & Ren, T. (2015) · Sensors · doi:10.3390/s150203224 · Cited by 92 · see citing works
Adabag, A. S., Grandits, G. A., Prineas, R. J., Crow, R. S., Bloomfield, H. E., & Neaton, J. D. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.01.021 · Cited by 85 · see citing works
Particle Filtering and Sensor Fusion for Robust Heart Rate Monitoring Using Wearable Sensors
Nathan, V., & Jafari, R. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2783758 · Cited by 79 · see citing works
Motion artifact cancellation in wearable photoplethysmography using gyroscope
Lee, H., Chung, H., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2879970 · Cited by 79 · see citing works
Self-citationSriramdas, R., Chiplunkar, S., Cuduvally, R., et al. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2387882 · Cited by 76 · see citing works
Lee, H., Chung, H., Ko, H., & Lee, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2801385 · Cited by 61 · see citing works
Self-citationRemoval of Respiratory Influences From Heart Rate Variability in Stress Monitoring
Choi, J., & Gutiérrez‐Osuna, R. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2150746 · Cited by 58 · see citing works
Gyroscope vs. accelerometer measurements of motion from wrist PPG during physical exercise
Casson, A. J., Vazquez Galvez, A., & Jarchi, D. (2016) · ICT Express · doi:10.1016/j.icte.2016.11.003 · Cited by 57 · see citing works
Jouven, X., Schwartz, P. J., Escolano, S., Straczek, C., Tafflet, M., Desnos, M., Empana, J. P., & Ducimetière, P. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp160 · Cited by 56 · see citing works
Fujita, Y., Hiromoto, M., & Sato, T. G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2697911 · Cited by 53 · see citing works
Brouwer, A.-M., van Dam, E., van Erp, J. B. F., Spangler, D. P., & Brooks, J. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00284 · Cited by 40 · see citing works
Forearm pressure distribution during ambulation with elbow crutches: a cross-sectional study
Fischer, J., Nüesch, C., Göpfert, B., et al. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-61 · Cited by 33 · see citing works
Brown, S. B. R. E., BROSSCHOT, J. F., Versluis, A., Thayer, J. F., & Verkuil, B. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2017.10.007 · Cited by 32 · see citing works
Wearable Photoplethysmographic Sensor based on Different LED Light Intensities
Lee, H., Ko, H., Jeong, C., & Lee, J. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2633575 · Cited by 30 · see citing works
Self-citationDedicated cardiac rehabilitation wearable sensor and its clinical potential
Lee, H., Chung, H., Ko, H., Jeong, C., Noh, S.-E., Kim, C., & Lee, J. (2017) · PLoS ONE · doi:10.1371/journal.pone.0187108 · Cited by 29 · see citing works
Self-citationLewis, G. F., Davila, M. I., Daubechies, I., Porges, S. W., & Wu, H. (2016) · Methods of Information in Medicine · doi:10.3414/me16-01-0026 · Cited by 25 · see citing works
Smartphone-Based Cardiac Rehabilitation Program: Feasibility Study
Chung, H., Ko, H., Thap, T., Jeong, C., Noh, S.-E., Yoon, K., & Lee, J. (2016) · PLoS ONE · doi:10.1371/journal.pone.0161268 · Cited by 17 · see citing works
Self-citationPiezoceramic Materials and Devices for Aerospace Applications
Panda, P. K. (2016) · Indian Institute of Metals series · doi:10.1007/978-981-10-2134-3_23 · Cited by 13 · see citing works
Piezoelectric Resonance Sensors of DC Magnetic Field
Fetisov, Y. K. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2301711 · Cited by 11 · see citing works
Carlson, G. M., Libbus, I., Amurthur, B., KenKnight, B. H., & Verrier, R. L. (2017) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12436 · Cited by 6 · see citing works
MERKELY, B., & Róka, A. (2011) · EP Europace · doi:10.1093/europace/euq452 · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Paliakaitė, B., Petrėnas, A., Sološenko, A., & Marozas, V. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102421 · Cited by 24 · see citing works
- Authors
- Lee, H., Chung, H., Kim, J.-W., & Lee, J.
- Affiliations
- Wonkwang University (KR)
- Jeonbuk National University (KR)
- Venue
- IEEE Sensors Journal
- Published
- 2019-05-15
- Volume
- 19
- Issue
- 10
- Pages
- 3861-3870
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2912981041
- Cited by
- 22
- References
- 43
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 7 · 2020: 3
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Sensors Journal (publishedVersion)
- Funders
- National Research Foundation of Korea
- Ministry of Science, ICT and Future Planning (NRF-2016R1D1A1B03934938, NRF-2015M3A9D7067215)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- motion artifact removal, piezoelectric pressure sensor, heart rate estimation, wearable sensors, wrist-worn sensors, physical activity monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review