Motion artifact identification and removal from wearable reflectance photoplethysmography using piezoelectric transducer

Lee, Hooseok, Chung, Heewon, Kim, Jong-Woong, Lee, Jinseok·2019·IEEE Sensors Journal

Abstract

Accurate heart rate estimation from reflectance photoplethysmography (PPG) during intense physical activity is difficult given unpredictable motion artifacts (MAs). Recent research has focused on the removal of MAs in PPG signals by considering acceleration signals as noise references. However, this approach does not always effectively remove MAs, as they can be associated with other noise sources. For instance, finger or hand motion reflects upon the wrist, corrupting the PPG signals, but an accelerometer cannot capture this type of MA. Hence, we propose adding a piezoelectric transducer on the wrist to identify noise originated from finger and hand motion. We first detail the developed wearable device that simultaneously measures PPG, acceleration, and piezoelectric pressure signals from the wrist. Then, the effectiveness of piezoelectric pressure signals for MA removal is verified from PPG signals collected under finger tapping and hand folding/unfolding, and from data of 17 healthy subjects undergoing physical activity. MA removal using both acceleration and piezoelectric pressure signals exhibits a mean absolute error of 1.58 beats per minute (bpm), considerably below the error of 3.75 bpm obtained using only acceleration signals. Therefore, measuring piezoelectric pressure signals on the wrist can improve heart rate estimation by providing more information of MAs corrupting PPG signals.

Integrity signals

Registry

Crossref · 10.1109/jsen.2019.2894640

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Secondary sensors can be integrated into PPG sensors to detect motion, including accelerometers, gyroscopes, piezoelectric transducers, or another wavelength of light as a motion reference.

    “As implemented by consumer-grade HR monitors, secondary sensors can also be integrated into PPG sensors to detect motion. These include accelerometers [175,176,177,178,179], gyroscopes [179,180], piezoelectric transducers [181], or the utilization of another wavelength of light as a motion reference [182,183].”
  • Both the piezoelectric transducer and another wavelength of light can pick up finer motions such as finger tapping.

    “Both the piezoelectric transducer and another wavelength of light can pick up these finer motions [181,182].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lee, H., Chung, H., Kim, J.-W., & Lee, J.
Affiliations
  • Wonkwang University (KR)
  • Jeonbuk National University (KR)
Venue
IEEE Sensors Journal
Published
2019-05-15
Volume
19
Issue
10
Pages
3861-3870
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W2912981041
Cited by
22
References
43
Citations by year
2026: 2 · 2025: 1 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 7 · 2020: 3
FWCI
1.15
Type
journal article
Language
en
Open access
closed
Locations
IEEE Sensors Journal (publishedVersion)
Funders
  • National Research Foundation of Korea
  • Ministry of Science, ICT and Future Planning (NRF-2016R1D1A1B03934938, NRF-2015M3A9D7067215)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
motion artifact removal, piezoelectric pressure sensor, heart rate estimation, wearable sensors, wrist-worn sensors, physical activity monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review