Real-Time Automatic Apneic Event Detection Using Nocturnal Pulse Oximetry
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Nocturnal pulse oximetry has been proposed as a simpler alternative to polysomnography in diagnosing sleep apnea. However, existing techniques are limited in terms of inability to provide time information on sleep apnea occurrence. This study aimed to propose a new strategy for near real-time automatic detection of apneic events and reliable estimation of apnea-hypopnea index using nocturnal pulse oximetry. METHODS: Among 230 polysomnographic recordings with apnea-hypopnea index values ranging from 0 to 86.5 events/h, 138 (60%) and the remaining 92 recordings (40%) were categorized as training and test sets, respectively. By extracting the quantitative characteristics caused by the apneic event for the amount and duration of the change in blood oxygen saturation value, we established the criteria to determine the occurrence of apneic event. Regression modeling was used to estimate the apnea-hypopnea index from the apneic event detection results. RESULTS: The minute-by-minute apneic segment detection exhibited an average accuracy of 91.0% and an average Cohen's kappa coefficient of 0.71. Between the apnea-hypopnea index estimations and reference values, the mean absolute error was 2.30 events/h. The average accuracy of our diagnosis of sleep apnea was 96.7% for apnea-hypopnea index cutoff values of ≥5, 10, 15, and 30 events/h. CONCLUSION: We developed an effective strategy to detect apneic events by using morphometric characteristics in the fluctuation of blood oxygen saturation values. SIGNIFICANCE: Our study could be potentially useful in home-based multinight apneic event monitoring for purposes of therapeutic intervention and follow-up study on sleep apnea.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Obstructive Sleep Apnea Is Independently Associated with Insulin Resistance
Ip, M. S. M., Lam, B., Ng, M. M. T., Lam, W. K., Tsang, K. W. T., & Lam, K. S. L. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2103001 · Cited by 1,300
Sleep-disordered Breathing and Coronary Artery Disease
MOOE, T., FRANKLIN, K. A., HOLMSTRÖM, K., RABBEN, T., & WIKLUND, U. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.10.2101072 · Cited by 401 · cited 1×
“Undiagnosed and untreated sleep apnea is a risk factor for hypertension [2], coronary artery disease [3], cardiac arrhythmias [4], stroke [5], diabetes mellitus [6], cognitive dysfunction [7], and depression [8].”
BackgroundThe Medical Cost of Undiagnosed Sleep Apnea
Kapur, V., Blough, D. K., Sandblom, R. E., Hert, R., de Maine, J. B., Sullivan, S. D., & Psaty, B. M. (1999) · Sleep · doi:10.1093/sleep/22.6.749 · Cited by 384
Cited by
Levy, J., Álvarez, D., Rosenberg, A. A., Alexandrovich, A., del Campo, F., & Behar, J. A. (2021) · npj Digital Medicine · doi:10.1038/s41746-020-00373-5 · Cited by 125
“, building on the parent model and desaturation definition of Jung et al.(51).”
MethodInfluentialO’Mahony, A. M., Garvey, J. F., & McNicholas, W. T. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd-sleep-2020-003 · Cited by 45
Feasibility of Single Channel Oximetry for Mass Screening of Obstructive Sleep Apnea
Behar, J. A., Palmius, N., Li, Q., Garbuio, S., Rizzatti, F. P. G., Bittencourt, L., Tufik, S., & Clifford, G. D. (2019) · EClinicalMedicine · doi:10.1016/j.eclinm.2019.05.015 · Cited by 37
Andrés-Blanco, A. M., Álvarez, D., Crespo, A., Arroyo, C. A., Cerezo-Hernández, A., Gutiérrez-Tobal, G. C., Hornero, R., & del Campo, F. (2017) · PLOS ONE · doi:10.1371/journal.pone.0188094 · Cited by 28
Behar, J. A., Palmius, N., Zacharie, S., Chocron, A., Penzel, T., Bittencourt, L., & Tufik, S. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab8856 · Cited by 20
Metadata
- Authors
- Jung, D. W., Hwang, S. H., Cho, J. G., Choi, B. H., Baek, H. J., Lee, Y. J., Jeong, D.-U., & Park, K. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2018-03
- Volume
- 65
- Issue
- 3
- Pages
- 706-712
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2626627616
- Cited by
- 61
- References
- 3
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.