Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Predictions on Maximum Calibration Period and Acceptable Error Limits
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Pulse transit time (PTT) is being widely pursued for ubiquitous blood pressure (BP) monitoring. PTT-based systems may require periodic cuff calibrations but can still be useful for hypertension screening by affording numerous out-of-clinic measurements that can be averaged. The objective was to predict the maximum calibration period that would not compromise accuracy and acceptable error limits in light of measurement averaging for PTT-based systems. METHODS: Well-known mathematical models and vast BP data were leveraged. Models relating PTT, age, and gender to BP were employed to determine the maximum time period for the PTT-BP calibration curve to change by <1 mmHg over physiological BP ranges for each age and gender. A model of within-person BP variability was employed to establish the screening accuracy of the conventional cuff-based approach. These models were integrated to investigate the screening accuracy of the average of numerous measurements of a PTT-based system in relation to the accuracy of its individual measurements. RESULTS: The maximum calibration period was about 1 year for a 30 year old and declined linearly to about 6 months for a 70 year old. A PTT-based system with a precision error of >12 mmHg for systolic BP could achieve the screening accuracy of the cuff-based approach via measurement averaging. CONCLUSION: This theoretical study indicates that PTT-based BP monitoring is viable even with periodic calibration and seemingly high measurement errors. SIGNIFICANCE: The predictions may help guide the implementation, evaluation, and application of PTT-based BP monitoring systems in practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935 · cited 9×
“However, smooth muscle contraction is a significantly greater factor in the periphery [1].”
BackgroundMethodInfluentialPrognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
Cited by
Recent Advancements in Emerging Technologies for Healthcare Management Systems: A Survey
Junaid, S. B., Imam, A. A., Balogun, A. O., De Silva, L. C., Surakat, Y. A., Kumar, G., Abdulkarim, M., Shuaibu, A. N., Garba, A., Sahalu, Y., et al. (2022) · Healthcare · doi:10.3390/healthcare10101940 · Cited by 353
Advances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292
“The distinctive aspect of the present paper is in the elaboration of a complete review of the PPG technique, a comparison with the ECG method, and a description of the most important variables (HRV, PTT, Pulse Rate Variability (PRV), Pulse Wave Velocity (PWV), etc.) which can be extracted from the PPG signal and used…”
BackgroundMethodInfluentialPP-Net: A Deep Learning Framework for PPG-Based Blood Pressure and Heart Rate Estimation
Panwar, M., Gautam, A., Biswas, D., & Acharyya, A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2990864 · Cited by 237
“BLOOD pressure (BP) and Heart Rate (HR) are the most important biomarkers as well as risk indicators for stroke and cardiovascular diseases [1]–[3] which are the leading causes of mortality and morbidity worldwide [4].”
BackgroundStergiou, G. S., Mukkamala, R., Avolio, A., Kyriakoulis, K. G., Mieke, S., Murray, A., Parati, G., Schutte, A. E., Sharman, J. E., Asmar, R., et al. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003224 · Cited by 227
“In addition, for cuffless technologies based on distal arterial waveform extraction, temperature variation or other factors inducing vasoconstriction or vasodilation may result in profound changes in the waveform [53,58,59,61,63].”
BackgroundSelf-citationSmartphone-based blood pressure monitoring via the oscillometric finger-pressing method
Chandrasekhar, A., Kim, C.-S., Naji, M., Natarajan, K., Hahn, J.-O., & Mukkamala, R. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aap8674 · Cited by 212
Self-citation
Metadata
- Authors
- Mukkamala, R., & Hahn, J.-O.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2018-06
- Volume
- 65
- Issue
- 6
- Pages
- 1410-1420
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2758839352
- Cited by
- 86
- References
- 3
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.