Dry-Contact Electrode Ear-EEG
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Ear-EEG is a recording method in which EEG signals are acquired from electrodes placed on an earpiece inserted into the ear. Thereby, ear-EEG provides a noninvasive and discreet way of recording EEG, and has the potential to be used for long-term brain monitoring in real-life environments. Whereas previously reported ear-EEG recordings have been performed with wet electrodes, the objective of this study was to develop and evaluate dry-contact electrode ear-EEG. METHODS: To achieve a well-functioning dry-contact interface, a new ear-EEG platform was developed. The platform comprised actively shielded and nanostructured electrodes embedded in an individualized soft-earpiece. The platform was evaluated in a study of 12 subjects and four EEG paradigms: auditory steady-state response, steady-state visual evoked potential, mismatch negativity, and alpha-band modulation. RESULTS: Recordings from the prototyped dry-contact ear-EEG platform were compared to conventional scalp EEG recordings. When all electrodes were referenced to a common scalp electrode (Cz), the performance was on par with scalp EEG measured close to the ear. With both the measuring electrode and the reference electrode located within the ear, statistically significant (p < 0.05) responses were measured for all paradigms, although for mismatch negativity, it was necessary to use a reference located in the opposite ear, to obtain a statistically significant response. CONCLUSION: The study demonstrated that dry-contact electrode ear-EEG is a feasible technology for EEG recording. SIGNIFICANCE: The prototyped dry-contact ear-EEG platform represents an important technological advancement of the method in terms of user-friendliness, because it eliminates the need for gel in the electrode-skin interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“All recordings were bandpass filtered with the EEGLAB FIR filter function “pop_eegfiltnew()” [23].”
MethodReport of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 1×
“IrO2 coatings have previously been used for both tissue stimulation [16], [17] and measuring biopotentials [18].”
MethodDry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061 · cited 3×
“When using dry-contact electrodes, no electrode gel is applied between the electrodes and the skin, instead the instrumentation and electrodes are designed to accommodate and reduce the effect of variations in the electrode-skin interface [6], [7].”
BackgroundMethodThe mismatch negativity (MMN): towards the optimal paradigm
Näätänen, R., Pakarinen, S., Rinne, T., & Takegata, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.04.001 · Cited by 721 · cited 1×
“The first peak of the MMN response was elicited around 150 ms, which is consistent with [29].”
ResultWearable Electroencephalography
Casson, A., Yates, D., Smith, S., Duncan, J., & Rodriguez-Villegas, E. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936545 · Cited by 404 · cited 1×
“personnel [1].”
Norton, J. J. S., Lee, D. S., Lee, J. W., Lee, W., Kwon, O., Won, P., Jung, S.-Y., Cheng, H., Jeong, J.-W., Akce, A., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1424875112 · Cited by 387 · cited 1×
“Dry-contact electrodes have been proposed in various designs, including mesh electrodes laminated onto the skin [4], flexible polymer based electrodes [3], [8], [9], and spring loaded electrodes [10], [11].”
BackgroundUnobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the ear
Debener, S., Emkes, R., De Vos, M., & Bleichner, M. (2015) · Scientific Reports · doi:10.1038/srep16743 · Cited by 382 · cited 1×
“[2]–[5].”
Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336 · cited 1×
“Dry-contact electrodes have been proposed in various designs, including mesh electrodes laminated onto the skin [4], flexible polymer based electrodes [3], [8], [9], and spring loaded electrodes [10], [11].”
BackgroundDry and Noncontact EEG Sensors for Mobile Brain–Computer Interfaces
Chi, Y. M., Wang, Y.-T., Wang, Y., Maier, C., Jung, T.-P., & Cauwenberghs, G. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2174652 · Cited by 297
Cited by
Recent advances in recording and modulation technologies for next-generation neural interfaces.
Hong, J.-W., Yoon, C., Jo, K., Won, J. H., & Park, S. (2021) · iScience · doi:10.1016/j.isci.2021.103550 · Cited by 25
Metadata
- Authors
- Kappel, S. L., Rank, M. L., Toft, H. O., Andersen, M., & Kidmose, P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2019-01
- Volume
- 66
- Issue
- 1
- Pages
- 150-158
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2799439111
- Cited by
- 172
- References
- 24
- FWCI
- 8.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.