The accurate classification of ambulation modes and estimation of walking parameters is a challenging problem that is key to many applications. Knowledge of the user's state can enable rehabilitative devices to adapt to changing conditions, while in a clinical setting it can provide physicians with more detailed patient activity information. This study describes the development and optimization process of a combined locomotion mode classifier and environmental parameter estimator using machine learning and wearable sensors. A detailed analysis of the best sensor types and placements for each problem is also presented to provide device designers with information on which sensors to prioritize for their application. For this study, 15 able-bodied subjects were unilaterally instrumented with inertial measurement unit, goniometer, and electromyography sensors and data were collected for extensive ranges of level-ground, ramp, and stair walking conditions. The proposed system classifies steady state ambulation modes with 99% accuracy and ambulation mode transitions with 96% accuracy, along with estimating ramp incline within 1.25 degrees, stair height within 1.29 centimeters, and walking speed within 0.04 meters per second. Mechanical sensors (inertial measurement units, goniometers) are found to be most important for classification, while goniometers dominate ramp incline and stair height estimation, and speed estimation is performed largely with a single inertial measurement unit. The feature tables and Matlab code to replicate the study are published as supplemental materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
White Paper: “Walking Speed: the Sixth Vital Sign”
Fritz, S., & Lusardi, M. (2009) · Journal of Geriatric Physical Therapy · doi:10.1519/00139143-200932020-00002 · Cited by 1,390 · cited 1×
“This adaptability is also important for monitoring rehabilitation, as walking speed is a common outcome measure [16], and the use of stair [17] and ramp [18] exercises improves muscle strength, balance, and walking speed.”
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542 · cited 4×
“Finally, as previous studies have shown that the fusion of mechanical and EMG sensors improve classification [4], [31] and regression [27], a more detailed analysis of the relative importance of each sensor type along with sensor location was conducted.”
BackgroundMethodResultInfluentialZeller, B. L., McCrory, J. L., Ben Kibler, W., & Uhl, T. L. (2003) · The American Journal of Sports Medicine · doi:10.1177/03635465030310032101 · Cited by 490
Cited by
A review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
Self-citationTask-agnostic exoskeleton control via biological joint moment estimation
Molinaro, D. D., Scherpereel, K. L., Schonhaut, E. B., Evangelopoulos, G., Shepherd, M. K., & Young, A. J. (2024) · Nature · doi:10.1038/s41586-024-08157-7 · Cited by 107
Self-citationLeveraging High-Density EMG to Investigate Bipolar Electrode Placement for Gait Prediction Models
Hodossy, B. K., Guez, A. S., Jing, S., Huo, W., Vaidyanathan, R., & Farina, D. (2024) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2024.3371099 · Cited by 10
Metadata
- Authors
- Camargo, J., Flanagan, W., Csomay-Shanklin, N., Kanwar, B., & Young, A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2021-05
- Volume
- 68
- Issue
- 5
- Pages
- 1569-1578
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W3134090569
- Cited by
- 78
- References
- 3
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.