A Transducer for the Continuous External Measurement of Arterial Blood Pressure
The DOI matches its Crossref record.
Abstract
The objective of the research was to develop a transducer to measure arterial blood pressure. It was required that the transducer provide a continuous measure of blood pressure, that it not encumber the subject and that it not require cannulation. Two basic techniques were investigated both analytically and experimentally. First, an indirect measurement of blood pressure based on arterial deflection was attempted. Difficulties of calibration; and sensitivity to physiological changes of skin and tissue around the artery led to the decision to attempt a more direct measurement of arterial blood pressure. In this second approach, arterial deflection is restrained by the transducer and the resultant restraining force is measured. A mathematical model of the transducer artery system was developed and was used as a guide for the design of the experimental prototype transducers. Tests performed on these experimental transducers gave results consistent with the predictions of the model. These transducers have been used to measure blood pressure at large superficial arteries, with results comparable to sphygmomanometer determinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Salvi, P., Lio, G., Labat, C., Ricci, E., Pannier, B., & Benetos, A. (2004) · Journal of Hypertension · doi:10.1097/00004872-200412000-00010 · Cited by 295
Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine
Saugel, B., Cecconi, M., Wagner, J. Y., & Reuter, D. A. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu447 · Cited by 268
Peter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261
Arterial tonometry: Review and analysis
Drzewiecki, G. M., Melbin, J., & Noordergraaf, A. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90037-4 · Cited by 235
Accuracy of a continuous blood pressure monitor based on arterial tonometry.
Sato, T., Nishinaga, M., Kawamoto, A., Ozawa, T., & Takatsuji, H. (1993) · Hypertension · doi:10.1161/01.hyp.21.6.866 · Cited by 217
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Cuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Orthostatic hypotension in very old individuals living in nursing homes: the PARTAGE study
Valbusa, F., Labat, C., Salvi, P., Vivian, M. E., Hanon, O., & Benetos, A. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834d3d73 · Cited by 91
Metadata
- Authors
- Pressman, G. L., & Newgard, P. M.
- Venue
- IRE Transactions on Bio-Medical Electronics
- Published
- 1963
- Volume
- 10
- Issue
- 2
- Pages
- 73-81
- ISSN
- 0096-1884 (ISSN-L)
- OpenAlex
- W2168078033
- Cited by
- 176
- References
- 0
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.