Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 119 of the 119 references it cites were found in a registry or an index.

Cuffless Blood Pressure Measurement

Open access
Mukkamala, Ramakrishna, Stergiou, George S., Avolio, Alberto P. · 2022 · Annual Review of Biomedical Engineering

Abstract

Cuffless blood pressure (BP) measurement has become a popular field due to clinical need and technological opportunity. However, no method has been broadly accepted hitherto. The objective of this review is to accelerate progress in the development and application of cuffless BP measurement methods. We begin by describing the principles of conventional BP measurement, outstanding hypertension/hypotension problems that could be addressed with cuffless methods, and recent technological advances, including smartphone proliferation and wearable sensing, that are driving the field. We then present all major cuffless methods under investigation, including their current evidence. Our presentation includes calibrated methods (i.e., pulse transit time, pulse wave analysis, and facial video processing) and uncalibrated methods (i.e., cuffless oscillometry, ultrasound, and volume control). The calibrated methods can offer convenience advantages, whereas the uncalibrated methods do not require periodic cuff device usage or demographic inputs. We conclude by summarizing the field and highlighting potentially useful future research directions.

Overview

Integrity signals

Registry

Crossref · 10.1146/annurev-bioeng-110220-014644

Cites

119 of 119 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 119 references

Research works printed but not linked: 10

  1. O'Brien E, 1994, J. Hum. Hypertens., 8, 73
  2. Marino PL., 2007, The ICU Book
  3. Penáz J., 1992, Physiol. Res., 41, 5
  4. Taira D, 2017, Hawai'i J. Med. Public Health, 76, 314
  5. Bera TK., 2014, J. Med. Eng., 381251
  6. Bramwell JC, 1922, Proc. R. Soc. B, 93, 298
  7. Bouguet J-Y., 2001, Pyramidal implementation of the affine Lucas Kanade feature tracker description of the algorithm
  8. Liu J, 2017, IEEE J. Transl. Eng. Heal. Med., 5, 1900110
  9. IEEE. 2014. IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices . New York: IEEE. 38 pp.
  10. IEEE. 2019. IEEE Standard for Wearable, Cuffless Blood Pressure Measuring Devices - Amendment 1 . New York: IEEE. 35 pp.

Cited by

See all 180

Metadata

Authors
Mukkamala, R., Stergiou, G. S., & Avolio, A. P.
Affiliations
  • University of Pittsburgh (US)
  • National and Kapodistrian University of Athens (GR)
  • Macquarie University (AU)
Venue
Annual Review of Biomedical Engineering
Published
2022-06-06
Volume
24
Issue
1
Pages
203-230
ISSN
  • 1523-9829 (ISSN-L)
  • 1545-4274
OpenAlex
W4220676114
Cited by
180
References
119
Citations by year
2026: 47 · 2025: 49 · 2024: 39 · 2023: 34 · 2022: 11
FWCI
2.96
Type
journal article
Language
en
Open access
Locations
  • Annual Review of Biomedical Engineering (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health
  • National Heart, Lung, and Blood Institute (R01HL146470)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
Keywords
cuffless blood pressure measurement, non-invasive blood pressure monitoring, pulse transit time, pulse wave analysis, volume control, hypertension, hypotension, wearable sensing, smartphone-based monitoring
MeSH terms
Blood Pressure, Blood Pressure Determination, Humans, Hypertension, Oscillometry, Pulse Wave Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cuffless Blood Pressure Measurement. https://app.cochat.ai/papers/10.1146/annurev-bioeng-110220-014644
The paper
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022). Cuffless Blood Pressure Measurement. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev-bioeng-110220-014644

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.