Cuffless Blood Pressure Measurement
Open accessAbstract
Cuffless blood pressure (BP) measurement has become a popular field due to clinical need and technological opportunity. However, no method has been broadly accepted hitherto. The objective of this review is to accelerate progress in the development and application of cuffless BP measurement methods. We begin by describing the principles of conventional BP measurement, outstanding hypertension/hypotension problems that could be addressed with cuffless methods, and recent technological advances, including smartphone proliferation and wearable sensing, that are driving the field. We then present all major cuffless methods under investigation, including their current evidence. Our presentation includes calibrated methods (i.e., pulse transit time, pulse wave analysis, and facial video processing) and uncalibrated methods (i.e., cuffless oscillometry, ultrasound, and volume control). The calibrated methods can offer convenience advantages, whereas the uncalibrated methods do not require periodic cuff device usage or demographic inputs. We conclude by summarizing the field and highlighting potentially useful future research directions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These devices use several different parameters and techniques to assess BP levels, including pulse transit time, pulse wave analysis, photoplethysmography and applanation tonometry, and have different intended uses (such as wearable devices for occasional use or for short-term continuous monitoring in an intensive care unit)55,56.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [56]
In the citing paper
“Therefore, these devices can provide detailed information on true BP profile and behaviour over time, as well as all types of BPV (including short-term to long-term BPV6,55–57), and have great potential for use in screening, early diagnosis, close monitoring and optimal management of hypertension.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [56]
In the citing paper
“Cuffless BP technologies embedded in wearable devices and smartphones can obtain multiple or even continuous measurements during routine activities for days, weeks or months, without the discomfort of cuff-induced limb compression.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [56]
In the citing paper
“However, cuffless devices have specific accuracy issues that are not present in the automated cuff BP devices, such as the need for individual user calibration and their questionable accuracy in tracking BP changes after calibration55,56.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [56]
Citations
Cites
Rapid object detection using a boosted cascade of simple features
Viola, P., & Jones, M. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.990517 · Cited by 18,300
MIMIC-III, a freely accessible critical care database
Johnson, A. E. W., Pollard, T. J., Shen, L., Lehman, L.-W. H., Feng, M., Ghassemi, M., Moody, B., Szolovits, P., Anthony Celi, L., & Mark, R. G. (2016) · Scientific Data · doi:10.1038/sdata.2016.35 · Cited by 8,141
Wang, H., Naghavi, M., Allen, C., Barber, R. M., Bhutta, Z. A., Carter, A., Casey, D. C., Charlson, F. J., Chen, A. Z., Coates, M. M., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31012-1 · Cited by 6,596
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Chow, C. K. (2013) · JAMA · doi:10.1001/jama.2013.184182 · Cited by 1,991
Prediction of cardiovascular risk factors from retinal fundus photographs via deep learning
Poplin, R., Varadarajan, A. V., Blumer, K., Liu, Y., McConnell, M. V., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0195-0 · Cited by 1,865
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719
Research works printed but not linked: 10
- O'Brien E, 1994, J. Hum. Hypertens., 8, 73
- Marino PL., 2007, The ICU Book
- Penáz J., 1992, Physiol. Res., 41, 5
- Taira D, 2017, Hawai'i J. Med. Public Health, 76, 314
- Bera TK., 2014, J. Med. Eng., 381251
- Bramwell JC, 1922, Proc. R. Soc. B, 93, 298
- Bouguet J-Y., 2001, Pyramidal implementation of the affine Lucas Kanade feature tracker description of the algorithm
- Liu J, 2017, IEEE J. Transl. Eng. Heal. Med., 5, 1900110
- IEEE. 2014. IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices . New York: IEEE. 38 pp.
- IEEE. 2019. IEEE Standard for Wearable, Cuffless Blood Pressure Measuring Devices - Amendment 1 . New York: IEEE. 35 pp.
Cited by
Blood pressure and its variability: classic and novel measurement techniques
Schutte, A. E., Kollias, A., & Stergiou, G. S. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00690-0 · Cited by 335
Self-citationStergiou, G. S., Mukkamala, R., Avolio, A., Kyriakoulis, K. G., Mieke, S., Murray, A., Parati, G., Schutte, A. E., Sharman, J. E., Asmar, R., et al. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003224 · Cited by 227
Self-citationKim, K. B., & Baek, H. J. (2023) · Electronics · doi:10.3390/electronics12132923 · Cited by 212
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 187
Self-citationSaugel, B., Fletcher, N., Gan, T. J., Grocott, M. P. W., Myles, P. S., Sessler, D. I., Auzinger, G., Chappell, D., Gan, T. J., Edwards, M., et al. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.04.046 · Cited by 180
Metadata
- Authors
- Mukkamala, R., Stergiou, G. S., & Avolio, A. P.
- Affiliations
- University of Pittsburgh (US)
- National and Kapodistrian University of Athens (GR)
- Macquarie University (AU)
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2022-06-06
- Volume
- 24
- Issue
- 1
- Pages
- 203-230
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W4220676114
- Cited by
- 180
- References
- 119
- Citations by year
- 2026: 47 · 2025: 49 · 2024: 39 · 2023: 34 · 2022: 11
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Annual Review of Biomedical Engineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Heart, Lung, and Blood Institute (R01HL146470)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Keywords
- cuffless blood pressure measurement, non-invasive blood pressure monitoring, pulse transit time, pulse wave analysis, volume control, hypertension, hypotension, wearable sensing, smartphone-based monitoring
- MeSH terms
- Blood Pressure, Blood Pressure Determination, Humans, Hypertension, Oscillometry, Pulse Wave Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cuffless Blood Pressure Measurement. https://app.cochat.ai/papers/10.1146/annurev-bioeng-110220-014644
- The paper
- Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022). Cuffless Blood Pressure Measurement. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev-bioeng-110220-014644
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.