CoChat

A Method of Measuring Eye Movemnent Using a Scieral Search Coil in a Magnetic Field

· 1963 · IEEE Transactions on Bio-medical Electronics
Cited by 1,838

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

With the subject exposed to an alternating magnetic field, eye position may be accurately recorded from the voltage generated in a coil of wire embedded in a scleral contact lens worn by the subject. Using two magnetic fields in quadrature phase and two coils on the lens, one may measure horizontal, vertical and torsional eye movements simultaneously. The instrument described has an accuracy and linearity of about 2 per cent of full scale, a resolution of 15 seconds of arc and a bandwidth of 1000 cyles per second.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbmel.1963.4322822

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Venue
IEEE Transactions on Bio-medical Electronics
Published
1963-10
Volume
10
Issue
4
Pages
137-145
ISSN
  • 0096-0616 (ISSN-L)
  • 2168-1600
OpenAlex
W2113705163
Cited by
1,838
References
9
FWCI
3.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.