Cited by 22Emotion and Mood RecognitionInnovative Human-Technology InteractionGaze Tracking and Assistive Technology

Interactive emotional content communications system using portable wireless biofeedback device

Kim, Dong, Kim, Jonghwa, Lee, Eui, Whang, Mincheol, Cho, Yongjoo·2011·IEEE Transactions on Consumer Electronics

Abstract

In this paper, we implemented an interactive emotional content communication system using a portable wireless biofeedback device to support convenient emotion recognition and immersive emotional content representation for users. The newly designed system consists of the portable wireless biofeedback device and a novel emotional content rendering system. The former performs the acquisition and transmission of three different physiological signals (photoplethysmography, skin temperature, and galvanic skin response) to the remote emotional content rendering system via Bluetooth links in real time. The latter displays video content concurrently manipulated using the feedback of the user¿s emotional state. The results of effectiveness of the system indicated that the response time of the emotional content communication system was nearly instant, the changes of between emotional contents and emotional states base on physiological signals was corresponded. The user¿s concentration was increased by watching the measuredemotion- based rendered visual stimuli. In the near future, the users of this proposed system will be able to create further substantial user-oriented content based on emotional changes.

Integrity signals

Registry

Crossref · 10.1109/tce.2011.6131173

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Conventional stress monitoring devices using commercial physiological sensors have bulky size to be worn or carried for daily time use.

    “The conventional researches about stress monitoring devices are focused on designing completed systems using commercial physiological sensors; thereby having bulky size41 to be worn or carried for daily time use.”

    From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [41]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kim, D., Kim, J., Lee, E., Whang, M., & Cho, Y.
Affiliations
  • Sangmyung University (KR)
  • National Institute for Mathematical Sciences (KR)
Venue
IEEE Transactions on Consumer Electronics
Published
2011-11
Volume
57
Issue
4
Pages
1929-1936
ISSN
0098-3063 (ISSN-L)
OpenAlex
W2118026452
Cited by
22
References
22
Citations by year
2022: 2 · 2021: 1 · 2020: 3 · 2019: 3 · 2018: 3 · 2017: 2 · 2016: 2 · 2015: 2 · 2014: 1 · 2013: 3
FWCI
1.65
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Consumer Electronics (publishedVersion)
Topics
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Emotion and Mood Recognition
  • Physical Sciences › Computer Science › Human-Computer Interaction › Innovative Human-Technology Interaction
  • Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
Keywords
emotion recognition, biofeedback device, physiological signals, photoplethysmography, skin temperature, skin conductance, Bluetooth, immersive media

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review