The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An Integrated Power-Efficient Active Rectifier With Offset-Controlled High Speed Comparators for Inductively Powered Applications
Open accessAbstract
We present an active full-wave rectifier with offset-controlled high speed comparators in standard CMOS that provides high power conversion efficiency (PCE) in high frequency (HF) range for inductively powered devices. This rectifier provides much lower dropout voltage and far better PCE compared to the passive on-chip or off-chip rectifiers. The built-in offset-control functions in the comparators compensate for both turn-on and turn-off delays in the main rectifying switches, thus maximizing the forward current delivered to the load and minimizing the back current to improve the PCE. We have fabricated this active rectifier in a 0.5-μm 3M2P standard CMOS process, occupying 0.18 mm(2) of chip area. With 3.8 V peak ac input at 13.56 MHz, the rectifier provides 3.12 V dc output to a 500 Ω load, resulting in the PCE of 80.2%, which is the highest measured at this frequency. In addition, overvoltage protection (OVP) as safety measure and built-in back telemetry capabilities have been incorporated in our design using detuning and load shift keying (LSK) techniques, respectively, and tested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
Self-citation
Cited by
Li, X., Tsui, C.-Y., & Ki, W.-H. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2387832 · Cited by 302
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
Self-citationA Wireless Magnetoresistive Sensing System for an Intraoral Tongue-Computer Interface
Park, H., Kiani, M., Lee, H.-M., Kim, J., Block, J., Gosselin, B., & Ghovanloo, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2227962 · Cited by 79
“This circuit also generates a short pulse for every detected bit “1” and applies it to the load-shift-keying (LSK) mechanism of the active rectifier [39].”
Self-citationDesign Considerations for Implantable Neural Circuits and Systems
Hsu, W.-Y., Hsieh, P.-H., & Chen, H. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_19 · Cited by 1
Metadata
- Authors
- Lee, H.-M., & Ghovanloo, M.
- Venue
- IEEE Transactions on Circuits and Systems I: Regular Papers
- Published
- 2011-08
- Volume
- 58
- Issue
- 8
- Pages
- 1749-1760
- ISSN
- 1549-8328 (ISSN-L)
- 1558-0806
- OpenAlex
- W2113705018
- Cited by
- 227
- References
- 1
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Integrated Power-Efficient Active Rectifier With Offset-Controlled High Speed Comparators for Inductively Powered Applications. https://app.cochat.ai/papers/10.1109/tcsi.2010.2103172
- The paper
- Lee, H.-M., & Ghovanloo, M. (2011). An Integrated Power-Efficient Active Rectifier With Offset-Controlled High Speed Comparators for Inductively Powered Applications. IEEE Transactions on Circuits and Systems I: Regular Papers. https://doi.org/10.1109/tcsi.2010.2103172
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.