Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 302

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

A 13.56 MHz Wireless Power Transfer System With Reconfigurable Resonant Regulating Rectifier and Wireless Power Control for Implantable Medical Devices

Li, Xing, Tsui, Chi-Ying, Ki, Wing-Hung·2015·IEEE Journal of Solid-State Circuits

Abstract

A 13.56 MHz wireless power transfer system with a 1X/2X reconfigurable resonant regulating (R3) rectifier and wireless power control for biomedical implants is presented. Output voltage regulation is achieved through two mechanisms: (1) a local PWM loop at the secondary side controls the duty cycle of mode-switching of the rectifier between the 1X and 2X modes; and (2) a global control loop obtains the mode-switching information from the secondary side and send it back to the primary side through the wireless channel and adjusts the transmitter power of the primary coil to adapt to load and coupling variations. Two novel backscattering uplink techniques are proposed for fast and energy-efficient data feedback. The first is for general data transmission using Manchester code; and the second is for fast duty cycle feedback to cater for fast load-transient responses. Stability analysis of the entire system with the two control loops is also presented. The primary transmitter and the secondary R3rectifier are fabricated in 0.35 μm CMOS process with the digital control circuits implemented using FPGA. The measured maximum received power and receiver efficiency are 102 mW and 92.6%, respectively. For load transients, the overshoot and the undershoot are approximately 110 mV and the settling times are less than 130 μs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jssc.2014.2387832

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 302

Metadata

Authors
Li, X., Tsui, C.-Y., & Ki, W.-H.
Venue
IEEE Journal of Solid-State Circuits
Published
2015-04
Volume
50
Issue
4
Pages
978-989
ISSN
  • 0018-9200 (ISSN-L)
  • 1558-173X
OpenAlex
W2095812537
Cited by
302
References
13
FWCI
14.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A 13.56 MHz Wireless Power Transfer System With Reconfigurable Resonant Regulating Rectifier and Wireless Power Control for Implantable Medical Devices. https://app.cochat.ai/papers/10.1109/jssc.2014.2387832
The paper
Li, X., Tsui, C.-Y., & Ki, W.-H. (2015). A 13.56 MHz Wireless Power Transfer System With Reconfigurable Resonant Regulating Rectifier and Wireless Power Control for Implantable Medical Devices. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2014.2387832

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.