A High-Sensitivity and Low-Walk Error LADAR Receiver for Military Application
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An integrated receiver with high sensitivity and low walk error for a military purpose pulsed time-of-flight (TOF) LADAR system is proposed. The proposed receiver adopts a dual-gain capacitive-feedback TIA (C-TIA) instead of widely used resistive-feedback TIA (R-TIA) to increase the sensitivity. In addition, a new walk-error improvement circuit based on a constant-delay detection method is proposed. Implemented in 0.35 μm CMOS technology, the receiver achieves an input-referred noise current of 1.36 pA/√Hz with bandwidth of 140 MHz and minimum detectable signal (MDS) of 10 nW with a 5 ns pulse at SNR=3.3, maximum walk-error of 2.8 ns, and a dynamic range of 1:12,000 over the operating temperature range of -40°C to +85°C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wideband Receiver for a Three-Dimensional Ranging LADAR System
Ngo, T.-H., Kim, C.-H., Kwon, Y. J., Ko, J. S., Kim, D.-B., & Park, H.-H. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2012.2215800 · Cited by 68 · cited 2×
“In the design, a three-stage inverting amplifier [2] is adopted for the TIA, rather than a common source or cascode amplifiers, which has high DC gain of about 80 dB with GBW of about 6.”
BackgroundMethodSelf-citation
Cited by
A Linear-Mode LiDAR Sensor Using a Multi-Channel CMOS Transimpedance Amplifier Array
Hong, C., Kim, S.-H., Kim, J.-H., & Park, S. M. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2852794 · Cited by 64
A 60-m range 6.16-mW laser-power linear-mode LiDAR system with multiplex ADC/TDC in 65-nm CMOS
Liu, M., Liu, H., Li, X., & Zhu, Z. (2020) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2019.2955671 · Cited by 54
“The inverter (INV) TIAs in [9], [13] with large power consumption showed a better”
BackgroundA Linear Dynamic Range Receiver with Timing Discrimination for Pulsed TOF Imaging LADAR Application
Zheng, H., Ma, R., Liu, M., & Zhu, Z. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2826860 · Cited by 46
“To linearly capture the intensity signal of the pulsed echo, the proposed receiver with AGC scheme shows better flexibility and compatibility, and higher cost-effectiveness than the prior arts [8], [18], and [21] with external voltage source and programmable digital codes, respectively.”
InfluentialMirrored Current-Conveyor Transimpedance Amplifier for Home Monitoring LiDAR Sensors
Yoon, D., Joo, J.-E., & Park, S. M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3043797 · Cited by 23
“[13] utilized a capacitive feedback (CF) topology to”
MethodA CMOS AFE With 37-nA rms Input-Referred Noise and Marked 96-dB Timing DR for Pulsed LiDAR
Li, K., Guo, J., & Zhao, Y. (2022) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2022.3181133 · Cited by 14
“than 1:12,000 (82 dB) [11] even with 4-level gain control [2].”
BackgroundMethodInfluential
Metadata
- Authors
- Cho, H.-S., Kim, C.-H., & Lee, S.-G.
- Venue
- IEEE Transactions on Circuits and Systems I: Regular Papers
- Published
- 2014-10
- Volume
- 61
- Issue
- 10
- Pages
- 3007-3015
- ISSN
- 1549-8328 (ISSN-L)
- 1558-0806
- OpenAlex
- W2045528440
- Cited by
- 88
- References
- 1
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.