A Wide Dynamic Range CMOS Laser Radar Receiver With a Time-Domain Walk Error Compensation Scheme
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This integrated receiver channel designed for a pulsed time-of-flight (TOF) laser rangefinder consists of a fully differential transimpedance amplifier channel and a timing discriminator. The amplitude-dependent timing walk error is compensated by measuring the width and rise time of the received pulse echo and using this information for calibration. The measured bandwidth, transimpedance and minimum detectable signal (SNR ~10) of the receiver channel are 230 MHz, 100 kQ and ~1 μA respectively. The single-shot precision of the receiver is ~3 cm at an SNR of 13 and the measurement accuracy is ±4 mm with compensation within a dynamic range of ~1:100000. The receiver circuit was realized in a 0.35 μm CMOS process and has a power consumption of 150 mW. The functionality of the receiver channel was verified over a temperature range of -20 °C to +50 °C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wideband Receiver for a Three-Dimensional Ranging LADAR System
Ngo, T.-H., Kim, C.-H., Kwon, Y. J., Ko, J. S., Kim, D.-B., & Park, H.-H. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2012.2215800 · Cited by 68 · cited 1×
“The performance of the proposed receiver is summarized and compared with figures presented in other recently published works in this field in Table I [13], [28]–[31].”
Cited by
A 60-m range 6.16-mW laser-power linear-mode LiDAR system with multiplex ADC/TDC in 65-nm CMOS
Liu, M., Liu, H., Li, X., & Zhu, Z. (2020) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2019.2955671 · Cited by 54
“1(b) shows an event-based triggering architecture in which the ADC is replaced by a continuous-time comparator and TDC [12]–[14].”
BackgroundA Linear Dynamic Range Receiver with Timing Discrimination for Pulsed TOF Imaging LADAR Application
Zheng, H., Ma, R., Liu, M., & Zhu, Z. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2826860 · Cited by 46
A CMOS AFE With 37-nA rms Input-Referred Noise and Marked 96-dB Timing DR for Pulsed LiDAR
Li, K., Guo, J., & Zhao, Y. (2022) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2022.3181133 · Cited by 14
“The achieved DR and walk error of this work is limited by the saturation of CSA, yet this work has superior noise performance and much better sensitivity comparing to [7] and [24], and the DR of this work can be further improved by designing a dynamic discharge circuit for the CSA.”
BackgroundMethodInfluentialA Low-Power Multimode Eight-Channel AFE for dToF LiDAR
Yang, Y., Liu, X., Yang, R., Ma, S., Xia, Y., Li, J., Zhang, B., Geng, L., & Li, D. (2024) · 2024 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas58744.2024.10557862 · Cited by 5
A CMOS Integrator-Based Clock-Free Time-to-Digital Converter for Home-Monitoring LiDAR Sensors
He, Y., & Park, S. M. (2022) · Sensors · doi:10.3390/s22020554 · Cited by 5
Metadata
- Authors
- Kurtti, S., Nissinen, J., & Kostamovaara, J.
- Venue
- IEEE Transactions on Circuits and Systems I: Regular Papers
- Published
- 2017-03
- Volume
- 64
- Issue
- 3
- Pages
- 550-561
- ISSN
- 1549-8328 (ISSN-L)
- 1558-0806
- OpenAlex
- W2558667450
- Cited by
- 66
- References
- 1
- FWCI
- 13.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Wide Dynamic Range CMOS Laser Radar Receiver With a Time-Domain Walk Error Compensation Scheme. https://app.cochat.ai/papers/10.1109/tcsi.2016.2619762
- The paper
- Kurtti, S., Nissinen, J., & Kostamovaara, J. (2017). A Wide Dynamic Range CMOS Laser Radar Receiver With a Time-Domain Walk Error Compensation Scheme. IEEE Transactions on Circuits and Systems I: Regular Papers. https://doi.org/10.1109/tcsi.2016.2619762
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.