CoChat

Advanced Valves and Pump Coordinated Hydraulic Control Design to Simultaneously Achieve High Accuracy and High Efficiency

Lyu, Litong, Chen, Zheng, Yao, Bin · 2021 · IEEE Transactions on Control Systems Technology
Cited by 100

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The rapid industrial development in the fields, such as robotics and high-tech manufacturing, has put forward much higher requirements for the application of high-performance electrohydraulic system, which should not only achieve high control accuracy but also work in a highly energy-efficient way. As we know, a valve control method could achieve good accuracy, but the low energy efficiency is its essential drawback. Conversely, a pump control method could achieve good energy efficiency, but the achievable accuracy is the drawback. Since neither individual valve control nor individual pump control method can meet the dual requirements, a novel idea of advanced valves and pump coordinated hydraulic control design is developed in this article. Within the control details, the high-performance adaptive robust control law is synthesized to handle the nonlinearities and uncertainties of the electrohydraulic system, and the optimized command generation approach for the valves and the pump is developed to attain the high level of energy efficiency while considering the control performance. Essentially, the control command of the pump is based on the desired model compensation to provide the majority amount of flow in an energy-efficient way, and control commands of the valves are generated directly by tracking errors to guarantee the control accuracy. The theoretical performance of the overall system control design is analyzed. Comparative experiments are conducted, and impressive results are obtained, showing that the proposed system could achieve even better tracking accuracy than the typical valve-controlled system, while the energy efficiency reached a high level. The advantages of the advanced system control design can be verified both in theory and experiments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tcst.2020.2974180

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 100

Metadata

Authors
Lyu, L., Chen, Z., & Yao, B.
Venue
IEEE Transactions on Control Systems Technology
Published
2021-01
Volume
29
Issue
1
Pages
236-248
ISSN
  • 1063-6536 (ISSN-L)
  • 1558-0865
  • 2374-0159
OpenAlex
W3008052590
Cited by
100
References
1
FWCI
7.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Advanced Valves and Pump Coordinated Hydraulic Control Design to Simultaneously Achieve High Accuracy and High Efficiency. https://app.cochat.ai/papers/10.1109/tcst.2020.2974180
The paper
Lyu, L., Chen, Z., & Yao, B. (2021). Advanced Valves and Pump Coordinated Hydraulic Control Design to Simultaneously Achieve High Accuracy and High Efficiency. IEEE Transactions on Control Systems Technology. https://doi.org/10.1109/tcst.2020.2974180

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.