Multistep Prediction of Physiological Tremor Based on Machine Learning for Robotics Assisted Microsurgery
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
For effective tremor compensation in robotics assisted hand-held device, accurate filtering of tremulous motion is necessary. The time-varying unknown phase delay that arises due to both software (filtering) and hardware (sensors) in these robotics instruments adversely affects the device performance. In this paper, moving window-based least squares support vector machines approach is formulated for multistep prediction of tremor to overcome the time-varying delay. This approach relies on the kernel-learning technique and does not require the knowledge of prediction horizon compared to the existing methods that require the delay to be known as a priori. The proposed method is evaluated through simulations and experiments with the tremor data recorded from surgeons and novice subjects. Comparison with the state-of-the-art techniques highlights the suitability and better performance of the proposed method.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Unlike physiological tremor, which is identified with low amplitude vibrations occurring within the spectral range of 6 to 14 Hz8 and affects the performance of individuals in high precision tasks such as robotic surgery9, PHT represents higher amplitude motion occurring in the broader frequency range of 3–14 Hz10.”
From PHTNet: Characterization and Deep Mining of Involuntary Pathological Hand Tremor using Recurrent Neural Network Models (2020) · cites this paper as [8]
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
Least Squares Support Vector Machines
Suykens, J. A. K., Van Gestel, T., De Brabanter, J., De Moor, B., & Vandewalle, J. (2002) · WORLD SCIENTIFIC eBooks · doi:10.1142/5089 · Cited by 3,642
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665 · cited 1×
“These techniques have been successfully applied in many domains such as pattern recognition and classification [23], [24], object detection and localization [25], [26], and prediction of physiological signals like respiration [27].”
MethodPattern recognition and machine learning
(2007) · Choice Reviews Online · doi:10.5860/choice.44-5091 · Cited by 2,650
Time Series Prediction Using Support Vector Machines: A Survey
Sapankevych, N., & Sankar, R. (2009) · IEEE Computational Intelligence Magazine · doi:10.1109/mci.2009.932254 · Cited by 1,129
Optimal control by least squares support vector machines
Suykens, J. A. K., Vandewalle, J., & De Moor, B. (2001) · Neural Networks · doi:10.1016/s0893-6080(00)00077-0 · Cited by 540 · cited 1×
“1) Standard LS-SVM: SVM map the input data into a higher-dimensional feature space via a nonlinear mapping ϕ(·) and then perform the linear regression [32], [33].”
MethodA Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
Deuschl, G., Raethjen, J., Lindemann, M., & Krack, P. (2001) · Muscle & Nerve · doi:10.1002/mus.1063 · Cited by 508 · cited 2×
“cacy of surgeon and restricts the number of qualified microsurgeons [1], [13].”
BackgroundAccurate On-line Support Vector Regression
Ma, J., Theiler, J., & Perkins, S. (2003) · Neural Computation · doi:10.1162/089976603322385117 · Cited by 408
Research works printed but not linked: 2
- cauwenberghs, 2001, Advances in Neural Information Processing System
- elbe, 1985, Tremor
Cited by
TTSA: An Effective Scheduling Approach for Delay Bounded Tasks in Hybrid Clouds
Yuan, H., Bi, J., Tan, W., Zhou, M., Li, B. H., & Li, J. (2017) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2016.2574766 · Cited by 207
Personalized Variable Gain Control With Tremor Attenuation for Robot Teleoperation
Yang, C., Luo, J., Pan, Y., Liu, Z., & Su, C.-Y. (2018) · IEEE Transactions on Systems, Man, and Cybernetics: Systems · doi:10.1109/tsmc.2017.2694020 · Cited by 176
“It is harmless for people’s normal daily activities [52].”
BackgroundSaturated Nussbaum Function Based Approach for Robotic Systems With Unknown Actuator Dynamics
Chen, C., Liu, Z., Zhang, Y., Chen, C. L. P., & Xie, S. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2015.2475363 · Cited by 160
Rebooting data-driven soft-sensors in process industries: A review of kernel methods
Liu, Y., & Xie, M. (2020) · Journal of Process Control · doi:10.1016/j.jprocont.2020.03.012 · Cited by 145
Evolution of Surgical Robot Systems Enhanced by Artificial Intelligence: A Review
Liu, Y., Wu, X., Sang, Y., Zhao, C., Wang, Y., Shi, B., & Fan, Y. (2024) · Advanced Intelligent Systems · doi:10.1002/aisy.202300268 · Cited by 119
Spoer, D. L., Kiene, J., Dekker, P. K., Huffman, S. S., Kim, K. G., Abadeer, A. I., & Fan, K. L. (2022) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000004608 · Cited by 68
Robotic Assistance by Impedance Compensation for Hand Movements While Manual Welding
Erden, M. S., & Billard, A. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2015.2478656 · Cited by 55
“Providing robotic assistance by compensating for impedance is close in spirit to the work that attempted to cancel hand tremor during micro surgery – by using weighted frequency Fourier linear combiner to estimate the magnitude and frequency of hand tremor [45, 46] or by employing reinforcement learning to predict the…”
MethodA New Deformation Model of Biological Tissue for Surgery Simulation
Zou, Y., Liu, P. X., Cheng, Q., Lai, P., & Li, C. (2016) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2016.2560938 · Cited by 52
A Quaternion Weighted Fourier Linear Combiner for Modeling Physiological Tremor
Adhikari, K., Tatinati, S., Ang, W. T., Veluvolu, K. C., & Nazarpour, K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2530564 · Cited by 48
“Multistep prediction is a potential approach to circumvent this problem [19], [35], [38].”
BackgroundSelf-citationAtashzar, S. F., Shahbazi, M., Samotus, O., Tavakoli, M., Jog, M. S., & Patel, R. V. (2016) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2016.2530632 · Cited by 45
Data-driven excavation trajectory planning for unmanned mining excavator
Zhang, T., Fu, T., Ni, T., Yue, H., Wang, Y., & Song, X. (2024) · Automation in Construction · doi:10.1016/j.autcon.2024.105395 · Cited by 41
Tatinati, S., Nazarpour, K., Ang, W. T., & Veluvolu, K. C. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2597119 · Cited by 36
“D), 2) md-ELM, 3) mdRELM, 4) OS-mdRELM, and 5) MWLSSVM (1-”
MethodSelf-citationShahtalebi, S., Atashzar, S. F., Samotus, O., Patel, R. V., Jog, M. S., & Mohammadi, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58912-9 · Cited by 32
A deep explainable artificial intelligent framework for neurological disorders discrimination
Shahtalebi, S., Atashzar, S. F., Patel, R. V., Jog, M., & Mohammadi, A. (2021) · Scientific Reports · doi:10.1038/s41598-021-88919-9 · Cited by 39
Automatic annotation of peaks in seismocardiogram for systolic time intervals
Shafiq, G., Tatinati, S., & Veluvolu, K. C. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591280 · Cited by 32
Self-citationWu, Q., & Peng, C. (2016) · Energies · doi:10.3390/en9080585 · Cited by 28
“For instance, Artificial Neural Networks (ANN) [18,19] and Least Squares Support Vector Machine (LSSVM) are considered efficient approaches due to their remarkable nonlinear mapping capabilities for wind power prediction, and the LSSVM methods have been successfully utilized in many other applications [20,21].”
MethodDeterministic and probabilistic interval prediction for wind farm based on VMD and weighted LS-SVM
Gendeel, M. A. A., Zhang, Y., Qian, X., & Xing, Z. (2019) · Energy Sources Part A Recovery Utilization and Environmental Effects · doi:10.1080/15567036.2019.1632980 · Cited by 28
Peng, J., Zhang, C., Kang, L., & Feng, G. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3204086 · Cited by 25
Xiao, F. (2019) · ISA transactions · doi:10.1016/j.isatra.2018.12.028 · Cited by 24
Broad learning extreme learning machine for forecasting and eliminating tremors in teleoperation
Yang, Q., Liang, K., Su, T., Geng, K., & Pan, M. (2021) · Applied Soft Computing · doi:10.1016/j.asoc.2021.107863 · Cited by 27
Lin, J., Liu, Z., Chen, C. L. P., & Zhang, Y. (2019) · Neurocomputing · doi:10.1016/j.neucom.2019.10.059 · Cited by 24
Lin, J., Liu, Z., Chen, C. L. P., & Zhang, Y. (2019) · Neurocomputing · doi:10.1016/j.neucom.2019.04.017 · Cited by 25
Systematic review of machine learning applications using nonoptical motion tracking in surgery
Carciumaru, T. Z., Tang, C. M., Farsi, M., Bramer, W. M., Dankelman, J., Raman, C., Dirven, C. M. F., Gholinejad, M., & Vasilic, D. (2025) · npj Digital Medicine · doi:10.1038/s41746-024-01412-1 · Cited by 24
“Two studies trained their ML models exclusively on optical data before testing on NOMTS data 94,95 (Table 2).”
InfluentialZhang, T., Gong, L., Wang, S., & Zuo, S. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02358-2 · Cited by 23
Three-domain fuzzy wavelet broad learning system for tremor estimation
Lin, J., Liu, Z., Chen, C. L. P., & Zhang, Y. (2019) · Knowledge-Based Systems · doi:10.1016/j.knosys.2019.105295 · Cited by 25
Noise-Resistant Statistical Traffic Classification
Wang, B., Zhang, J., Zhang, Z., Pan, L., Xiang, Y., & Xia, D. (2017) · IEEE Transactions on Big Data · doi:10.1109/tbdata.2017.2735996 · Cited by 24
“This technique extracts a set of statistical features from traffic flows and employs machine learning (ML) [6] for application identification.”
MethodKong, D., Wang, W., Guo, D., & Shi, Y. (2022) · Applied Sciences · doi:10.3390/app12104993 · Cited by 21
A Tremor Suppression and Noise Removal Algorithm for Microscopic Robot-Assisted Cataract Surgery
Bian, G., Wang, J., Fu, P., Wei, B.-T., Li, M., & Li, Z. (2023) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2023.3254161 · Cited by 22
“The tremor amplitude of each spindle approaches 50 μ m, and the frequency is in the range of 8–15 Hz [18].”
BackgroundFan, Y., He, Y., & Tan, U.-X. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.2975836 · Cited by 21
“problem [23], [24], our proposed method has better versatility and is lightweight (requiring less computational resources), and is thus, much suitable for FPGA target and attractive in practice.”
BackgroundMethodInfluentialPhysiological Tremor Filtering Without Phase Distortion for Robotic Microsurgery
Adhikari, K., Tatinati, S., Veluvolu, K. C., & Chambers, J. A. (2020) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2020.3041427 · Cited by 22
“threshold of Accuracy (%) is 70%, as previously validiated in [32], [33].”
BackgroundMethodInfluentialSelf-citationSabique, P. V., Ganesh, P., & Ramachandran, S. (2023) · Expert Systems with Applications · doi:10.1016/j.eswa.2023.122221 · Cited by 20
Multimodal data fusion framework enhanced robot-assisted minimally invasive surgery
Qi, W., Su, H., Fan, K., Chen, Z., Li, J., Zhou, X., Hu, Y., Zhang, L., Ferrigno, G., & Momi, E. D. (2021) · Transactions of the Institute of Measurement and Control · doi:10.1177/0142331220984350 · Cited by 18
“An augmented feature space was established by using a combination of SVM and hidden Markov model (HMM) in robotassisted surgical systems (Tatinati et al., 2014).”
Tremor Estimation and Removal in Robot-Assisted Surgery Using Lie Groups and EKF
Rana, R., Gaur, P., Agarwal, V., & Parthasarathy, H. (2019) · Robotica · doi:10.1017/s0263574719000341 · Cited by 17
Design and Control of Fully Handheld Microsurgical Robot for Active Tremor Cancellation
Kim, E., Choi, I., & Yang, S. (2021) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48506.2021.9561200 · Cited by 19
“In contrast, the physiological tremor is known to have an RMS (root-mean-square) amplitude on an order of 50-200 μm at a frequency commonly in a 6-14 Hz band [18].”
BackgroundClassification of Fatigue Phases in Healthy and Diabetic Adults Using Wearable Sensor
Aljihmani, L., Kerdjidj, O., Zhu, Y., Mehta, R. K., Erraguntla, M., Sasangohar, F., & Qaraqe, K. A. (2020) · Sensors · doi:10.3390/s20236897 · Cited by 20
“ML applies mathematical algorithms that can discover subjective designs or structure in the data and predict the result for the new inputs based on the experienced models [34,35].”
BackgroundAtashzar, S. F., Jafari, N., Shahbazi, M., Janz, H. L., Tavakoli, M., Patel, R. V., & Adams, K. D. (2017) · Journal of Medical Robotics Research · doi:10.1142/s2424905x17400013 · Cited by 15
“In the literature, BMFLC fi ltering has also been used for extracting physiological hand tremor of surgeons [36 – 38] and recently has shown good performance in extracting pathological involuntary motions [33].”
MethodPrediction of Voluntary Motion Using Decomposition-and-Ensemble Framework With Deep Neural Networks
Yoon, D., Kim, E., Choi, I., Han, S. W., & Yang, S. (2020) · IEEE Access · doi:10.1109/access.2020.3035498 · Cited by 12
“In contrast, physiological tremor is originated from the combination ofmechanical-reflex components and oscillation in a central nervous system [12], which is known to have an RMS (root-mean-square) amplitude on the order of 50-200 μm at a frequency commonly in the 6-14 Hz band [13].”
BackgroundSavage, S. A., Seth, I., Angus, Z. G., & Rozen, W. M. (2024) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2024.11.023 · Cited by 13
Rahman, E., Esfahlani, S. S., Rao, P., Garcia, P., Ioannidis, S., Nosta, J., Rahman, Z., & Webb, W. R. (2025) · European Journal of Plastic Surgery · doi:10.1007/s00238-025-02278-6 · Cited by 11
“Fichera D (2013) [48] explored AI in laser pho-nomicrosurgery, while Tatinati KC (2015) [97] focused on tremor prediction for microsurgery.”
Wang, Y., Tatinati, S., Adhikari, K., Huang, L., Nazarpour, K., Ang, W. T., & Veluvolu, K. C. (2018) · IEEE Access · doi:10.1109/access.2018.2852323 · Cited by 11
“Furthermore, while optimizing for 3D models, the computational complexity of LSSVM-3D is three times the computational requirement of LSSVM-1D whereas the innate structure of ELM keeps the computational complexity of ELM-3D similar to ELM-1D.”
BackgroundMethodSelf-citationTatinati, S., Nazarpour, K., Ang, W. T., & Veluvolu, K. C. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.04.021 · Cited by 10
Self-citationPan, M., Yang, Q., Su, T., Geng, K., & Liang, K. (2022) · Applied Soft Computing · doi:10.1016/j.asoc.2022.109702 · Cited by 13
An Incremental Broad-Learning-System-Based Approach for Tremor Attenuation for Robot Tele-Operation
Lai, G., Liu, W., Yang, W., Zhong, H., He, Y., & Zhang, Y. (2023) · Entropy · doi:10.3390/e25070999 · Cited by 9
“These tremors exist in every part of the human body with an amplitude range between 50 and 100 μm in each principal axis, and their dominant frequency is usually distributed in the range of 8–12 Hz [6,7].”
BackgroundExploring data-driven modeling and analysis of nonlinear pathological tremors
Wang, J., & Barry, O. (2021) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.107659 · Cited by 8
Rasheed, A., Kim, J., Ang, W. T., & Veluvolu, K. C. (2025) · ISA Transactions · doi:10.1016/j.isatra.2024.12.040 · Cited by 6
Self-citationShahvandi, M. K. (2020) · arXiv (Cornell University) · doi:10.3929/ethz-b-000459466 · Cited by 9
Wang, W., Jia, B., Ma, J., Wang, X., & Song, H. (2024) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2666 · Cited by 5
“The vibration of surgical instruments can severely affect a surgeon's operation, increase the difficulty of the operation, reduce the accuracy of the operation, and even threaten the safety of the operation of the operation [11].”
State of the Art and Development Trend of Laparoscopic Surgical Robot and Master Manipulator
Han, R., Sang, H., Liu, F., & Huang, F. (2024) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.70020 · Cited by 8
Lai, G., Liu, W., Yang, W., & Zhang, Y. (2023) · Applied Sciences · doi:10.3390/app13020890 · Cited by 6
Chen, M., Shuang, F., Li, S., & Liu, X. (2025) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2025.105189 · Cited by 5
An Improved Soft Tissue Deformation Simulation Model Based on Mass Spring
Tan, D., Zhao, J., Shi, W., Li, X., Yang, H., & Jiang, Z. (2020) · International Conference on Virtual Reality and Visualization · doi:10.1109/icvrv51359.2020.00034 · Cited by 4
Tremor Attenuation For Robot Teleoperation By A Broad Learning System-Based Approach
Liu, W., Lai, G., & Liu, A. (2021) · China Automation Congress (CAC) · doi:10.1109/cac53003.2021.9727960 · Cited by 4
“The physiological tremor has the characteristics of low amplitude and high frequency, and these tremor signals exist in every part of the human body [7].”
BackgroundNiu, B., Yang, D., Zhang, L., Ji, Y., Jiang, L., & Liu, H. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3559495 · Cited by 3
“IC is similar to using filtering compensation (FC) to eliminate hand tremors in leader–follower surgery [28], [29].”
Multiple Order Fourier Linear Combiner: Estimating Phase Shift for Real-Time Vibration Compensation
He, Y., Fan, Y., & Tan, U.-X. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3179703 · Cited by 3
Wang, J., & Barry, O. R. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3111878 · Cited by 3
Xiao, F., Gao, Y., Shengxin, W., & Zhao, J. (2015) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2015.7418925 · Cited by 4
“1 , [0 0 0 0 0 0 0 0 0] R Q I P Q w MWLS-SVM[8] 500, 100, 0.”
MethodInfluentialAdhikari, K., Nazarpour, K., Veluvolu, K. C., & Tatinati, S. (2015) · IET International Conference on Intelligent Signal Processing (ISP) · doi:10.1049/cp.2015.1782 · Cited by 3
“This algorithm has be been most effective to date and it has been also implemented and extended for tremor estimation and prediction by other researchers already [8].”
MethodSelf-citationDetection of Tremor Associated with Rest and Effort Activity Using Machine Learning
Aljihmani, L., Kerdjidj, O., Zhu, Y., Mehta, R. K., & Qaraqe, K. A. (2020) · International Conference Automatics and Informatics (ICAI) · doi:10.1109/icai50593.2020.9311368 · Cited by 4
“High-frequency low amplitude (6-14 Hz, 50 – 100 μ m) physiological tremor affects the precise movements [3].”
BackgroundTremor suppression for master-slave teleoperated robot based on machine learning: A review
Liang, K., Su, Y., Du, G., Ma, C., Li, M., & Pan, M. (2025) · Neurocomputing · doi:10.1016/j.neucom.2025.129421 · Cited by 7
Freccero, A., Feder, M., Grioli, G., Catalano, M. G., Massone, A., Bicchi, A., & Casadio, M. (2025) · Applied Sciences · doi:10.3390/app15041792 · Cited by 2
“Other methods involve exploiting signal processing techniques, such as filters [12].”
Lin, J., Liu, Z., & Lai, J. (2018) · International Conference on Security, Pattern Analysis, and Cybernetics (SPAC) · doi:10.1109/spac46244.2018.8965489 · Cited by 2
“In the existing literature, tremor has been defined as a involuntary, rough motion [7] which exists in all healthy body [8] and is generally limited to 4 Hz bandwidth [7], [9].”
BackgroundTremor estimation and filtering in robotic-assisted surgery
Jia, B., Wang, W., Tian, X., & Wang, X. (2025) · Cognitive Neurodynamics · doi:10.1007/s11571-025-10387-y · Cited by 1
He, Y., Fan, Y., Zhang, D., & Tan, U.-X. (2018) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2018.8665174 · Cited by 1
“[14] proposed moving window-based least squares support vector machines (MWLS-SVM).”
MethodReal-Time Vibration Estimation and Compensation With Long Short-Term Memory Recurrent Neural Network
He, Y., Zhang, Y., Fan, Y., & Tan, U.-X. (2024) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2024.3496533 · Cited by 2
“Astosensornoise and drift filtering, AI-adied adaptive filters are also proposed [27], [28].”
Choi, I., Kim, E., & Sungwook (2024) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros58592.2024.10801436 · Cited by 1
“Since the physiological hand tremor is known to have an RMS (root-mean-square) amplitude on an order of 50-200 µ m at a frequency commonly in a 6-14 Hz band [15], the manipulator has sufficient workspace to compensate for both physiological tremors and respiratory motion of the tissue.”
Respiratory motion prediction using moving window based online training approach for LS-SVM
Tatinati, S., & Veluvolu, K. C. (2015) · International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2015.7095297 · Cited by 1
“LS-SVM is one of the most popular techniques for nonlinear regression, classification and function estimation [13], [15]–[18].”
MethodSelf-citationMachine Learning for Fatigue Estimation and Prediction “An Introduction Study”
Aljihmani, L., Ursuțiu, D., Samoilă, C., & Qaraqe, K. A. (2022) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-93564-1_25 · Cited by 1
Statistical learning modeling for tremor signal based on empirical mode decomposition method
Zhong, S. S., & Huang, X. (2015) · IEEE International Conference on Software Engineering and Service Science (ICSESS) · doi:10.1109/icsess.2015.7339212
“robotics assisted microsurgery([4]), which is necessary to model and analyze the tremor signal.”
BackgroundLocal Circular Modeling based Real-time Pathological Tremor Characterization for FES Applications
Tatinati, S., Wang, Y., Veluvolu, K. C., & Ang, W. T. (2015) · International Convention on Rehabilitation Engineering & Assistive Technology
Self-citationThree-dimensional modeling of physiological tremor for hand-held surgical robotic instruments
Tatinati, S., Aye, Y. N., Pual, A., Ang, W. T., & Veluvolu, K. C. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591533
“In the recent past decade, several signal processing techniques have been developed/customized to model the tremulous motion, sucg as Band-limited multiple Fourier linear combiner (BMFLC) [3], [4], [6]–[9].”
BackgroundMethodSelf-citationCooperative Statistical Traffic Big Data Classification with Machine Learning
Roshini, G., Nathiya, M., Keerthana, M., & A.Sujethira (2018)
The Online Soft Computing Models of key variables based on the Boundary Forest method
Deng, C., Wang, X., Gu, J., & Wang, W. (2019) · Soft Computing · doi:10.1007/s00500-019-04584-1
He, Y., Fan, Y., & Tan, U.-X. (2019) · International Conference on Advanced Robotics (ICAR) · doi:10.1109/icar46387.2019.8981564
“(ELM) [10] and moving window-based least squares support vector machines (MWLS-SVM) [11] both apply trained mapping to remove drift.”
MethodInfluentialUser experience-enhanced teleoperation control
Yang, C., Luo, J., & Wang, N. (2023) · Elsevier eBooks · doi:10.1016/b978-0-32-395143-2.00008-5
Chao, G., Pan, B., Guojun, N., Ai, Y., & Fu, Y. (2024) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062241304845
Diffusion Policy Framework for Optimal RCM Selection in Autonomous Laparoscope View Control
Li, X., Zhang, X., Zhang, J., Hou, W., Sun, L., & Lu, B. (2026) · International Conference on Control and Automation · doi:10.1109/icca69928.2026.11617997
“With the popularization and application of MIS and robotics [10], research on laparoscopic robots has become increasingly active [11].”
Pathological tremor filtering and prediction using RSSA-based RVFL networks
Rasheed, A., Tsai, C., & Veluvolu, K. C. (2026) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2026.111409
Self-citation
Metadata
- Authors
- Tatinati, S., Veluvolu, K. C., & Ang, W. T.
- Affiliations
- Kyungpook National University (KR)
- Nanyang Technological University (SG)
- Venue
- IEEE Transactions on Cybernetics
- Published
- 2015-02
- Volume
- 45
- Issue
- 2
- Pages
- 328-339
- ISSN
- 2168-2267 (ISSN-L)
- 2168-2275
- OpenAlex
- W1976018656
- Cited by
- 77
- References
- 36
- Citations by year
- 2026: 2 · 2025: 8 · 2024: 8 · 2023: 5 · 2022: 6 · 2021: 7 · 2020: 9 · 2019: 9 · 2018: 4 · 2017: 3 · 2016: 9 · 2015: 7
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Cybernetics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Basic Science Research Program through the National Research Foundation of Korea (NRF)
- Ministry of Education, Science, and Technology (NRF-2014R1A1A2A10056145)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Iterative Learning Control Systems
- Keywords
- physiological tremor, tremor compensation, multi-step forecasting, least squares support vector machine, moving window, kernel learning, tremor filtering
- MeSH terms
- Computer Simulation, Humans, Microsurgery, Signal Processing, Computer-Assisted, Tremor, Models, Statistical, Support Vector Machine, Robotic Surgical Procedures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.