Abstract
This paper deals with the effect of supply frequency on partial discharge phenomena. Results of measurements performed on artificial and practical test objects are compared with computer simulations based on physical models. This comparative analysis points out and explains the differences in partial discharge phenomena observed in tests performed at different frequencies (from 0.1 to 300 Hz). The consequences associated to the use of different supply frequencies in practical applications are, eventually, outlined.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Partial discharge (PD) is the main responsible factor for occurring the insulation deterioration in HV systems or LV ones where overvoltage or surge may take place [155].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [155]
Citations
Cites
A generalized approach to partial discharge modeling
Niemeyer, L. (1995) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/94.407017 · Cited by 751
Measurement and simulation of PD in epoxy voids
Gutfleisch, F., & Niemeyer, L. (1995) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/94.469970 · Cited by 392
Digital detection and fuzzy classification of partial discharge signals
Contin, A., Cavallini, A., Montanari, G. C., Pasini, G., & Puletti, F. (2002) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2002.1007695 · Cited by 369
Self-citationPartial discharges in ellipsoidal and spheroidal voids
Crichton, G. C., Karlsson, P. W., & Pedersen, A. (1989) · IEEE Transactions on Electrical Insulation · doi:10.1109/14.90292 · Cited by 276
Advanced PD inference in on-field measurements. I. Noise rejection
Cavallini, A., Contin, A., Montanari, G. C., & Puletti, F. (2003) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2003.1194102 · Cited by 205
Self-citationBoyle, D. (1988) · Power Engineering Journal · doi:10.1049/pe:19880062 · Cited by 200
Karsai, K., Kerényi, D., & Kiss, L. (1987) · REAL-EOD (Library of the Hungarian Academy of Sciences and the Information Center Oriental Collection) · Cited by 157
The transport and trapping of electrons in polymers
WATSON, P. K. (1995) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/94.469986 · Cited by 116
Gockenbach, E., & Hauschild, W. (2000) · IEEE Electrical Insulation Magazine · doi:10.1109/57.887600 · Cited by 63
A generalized model for partial discharge processes based on a stochastic process approach
Heitz, C. (1999) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/32/9/312 · Cited by 60
Research works printed but not linked: 5
- morshuis, 1993, Partial Discharge Mechanisms
- 2001, IEC 60270 Partial Discharge Measurements
- meunier, 2000, Characterization of charge carrier traps in polymeric insulations, IEEE CEIDP, 21
- 1974, Recommended Practice for Insulation Testing of Large AC Rotating Machinery with High Voltage at Very Low Frequency
- 1992, IEEE Std C57 125 IEEE guide for failure investigation documentation and analysis for power transformers and shunt reactors
Cited by
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
Bringing an insulation to failure: the role of space charge
Montanari, G. C. (2011) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2011.5739438 · Cited by 327
Self-citationNumerical modeling of partial discharges in a solid dielectric-bounded cavity: A review
Pan, C., Chen, G. Y., Tang, J., & Wu, K. (2019) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2019.007945 · Cited by 151
Partial discharge behavior and ground insulation life expectancy under different voltage frequencies
Liu, T., Li, Q., Huang, X., Lu, Y., Asif, M., & Wang, Z. (2018) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2018.006810 · Cited by 83
Partial discharges in a cavity at variable applied frequency part 1: measurements
Forssén, C., & Edin, H. (2008) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2008.4712663 · Cited by 88
Metadata
- Authors
- Cavallini, A., & Montanari, G. C.
- Affiliations
- University of Bologna (IT)
- ORCID
- Cavallini, A.
- Venue
- IEEE Transactions on Dielectrics and Electrical Insulation
- Published
- 2006-02
- Volume
- 13
- Issue
- 1
- Pages
- 111-121
- ISSN
- 1070-9878 (ISSN-L)
- OpenAlex
- W2116983999
- Cited by
- 144
- References
- 20
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 2 · 2023: 11 · 2022: 15 · 2021: 11 · 2020: 12 · 2019: 11 · 2018: 11 · 2017: 11 · 2016: 5 · 2015: 4 · 2014: 4 · 2013: 5 · 2012: 10
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Dielectrics and Electrical Insulation (publishedVersion)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › High voltage insulation and dielectric phenomena
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Transformer Diagnostics and Insulation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Electromagnetic Research
- Keywords
- supply frequency, partial discharge, insulation systems, high-frequency measurement, physical modeling, computer simulation, insulation testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.