In recent years, marked improvement has been achieved in the design and manufacture of stator winding. However, motors driven by solid-state inverters undergo severe voltage stresses due to rapid switch-on and switch-off of semiconductor switches. Also, induction motors are required to operate in highly corrosive and dusty environments. Requirements such as these have spurred the development of vastly improved insulation material and treatment processes. But cage rotor design has undergone little change. As a result, rotor failures now account for a larger percentage of total induction motor failures. Broken cage bars and bearing deterioration are now the main cause of rotor failures. Moreover, with advances in digital technology over the last years, adequate data processing capability is now available on cost-effective hardware platforms, to monitor motors for a variety of abnormalities on a real time basis in addition to the normal motor protection functions. Such multifunction monitors are now starting to displace the multiplicity of electromechanical devices commonly applied for many years. For such reasons, this paper is devoted to a comparison of signal processing-based techniques for the detection of broken bars and bearing deterioration in induction motors. Features of these techniques which are relevant to fault detection are presented. These features are then analyzed and compared to deduce the most appropriate technique for induction motor rotor fault detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
(2022) · Modern Signal Processing · doi:10.1515/9783110475562-004 · Cited by 996
APPLICATION OF WAVELETS TO GEARBOX VIBRATION SIGNALS FOR FAULT DETECTION
Wang, W. J., & McFadden, P. D. (1996) · Journal of Sound and Vibration · doi:10.1006/jsvi.1996.0226 · Cited by 470
Time-frequency signal analysis
Boashash, B. (1993) · Medical Entomology and Zoology · Cited by 465
Benbouzid, M. E. H., Vieira, M., & Theys, C. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.737588 · Cited by 378
Self-citationThorsen, O. V., & Dalva, M. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.464536 · Cited by 344
Methods of Motor Current Signature Analysis
Kliman, G. B., & Stein, J. (1992) · Electric Machines & Power Systems · doi:10.1080/07313569208909609 · Cited by 330
Self-citationEffects of time-varying loads on rotor fault detection in induction machines
Schoen, R. R., & Habetler, T. G. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.395302 · Cited by 272
Yazici, B., & Kliman, G. B. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.753640 · Cited by 266
Self-citationThorsen, O. V., & Dalva, M. (2002) · Proceedings of IEEE Petroleum and Chemical Industry Technical Conference (PCIC '94) · doi:10.1109/pcicon.1994.347637 · Cited by 264
Cited by
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
Gangsar, P., & Tiwari, R. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.106908 · Cited by 605
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568
Grubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Self-citationFault Diagnosis in Industrial Induction Machines Through Discrete Wavelet Transform
Bouzida, A., Touhami, O., Ibtiouen, R., Belouchrani, A., Fadel, M., & Rezzoug, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2095391 · Cited by 325
Fault Diagnosis for Electrical Systems and Power Networks: A Review
Furse, C. M., Kafal, M., Razzaghi, R., & Shin, Y.-J. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2987321 · Cited by 296
Puche-Panadero, R., Pineda-Sanchez, M., Riera-Guasp, M., Roger-Folch, J., Hurtado-Perez, E., & Perez-Cruz, J. (2009) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2008.2003207 · Cited by 288
Fault-tolerant control in variable speed drives: a survey
Campos-Delgado, D. U., Espinoza-Trejo, D. R., & Palacios, E. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070203 · Cited by 228
Giantomassi, A., Ferracuti, F., Iarlori, S., Ippoliti, G., & Longhi, S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2370936 · Cited by 168
Metadata
- Authors
- Benbouzid, M. E. H., & Kliman, G. B.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2003-06
- Volume
- 18
- Issue
- 2
- Pages
- 238-244
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W2156091126
- Cited by
- 485
- References
- 15
- FWCI
- 28.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.