The DOI matches its Crossref record.
Comparison of Direct-Drive and Geared Generator Concepts for Wind Turbines
Open accessAbstract
The objective of this paper is to compare five different generator systems for wind turbines, namely the doubly-fed induction generator with three-stage gearbox (DFIG3G), the direct-drive synchronous generator with electrical excitation (DDSG), the direct-drive permanent-megnet generator (DDPMG), the permanent-magnet generator with single stage gearbox (PMG1G), and the doubly-fed induction generator with single-stage gearbox (DFIG1G). The comparison is based on cost and annual energy yield for a given wind climate. The DFIG3G is a cheap solution using standard components. The DFIG1G seems the most attractive in terms of energy yield divided by cost. The DDPMG has the highest energy yield, but although it is cheaper than the DDSG, it is more expensive than the generator systems with gearbox.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High-power wind energy conversion systems: State-of-the-art and emerging technologies
Yaramasu, V., Wu, B., Sen, P. C., Kouro, S., & Narimani, M. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378692 · Cited by 991
Overview of different wind generator systems and their comparisons
Li, H., & Chen, Z. (2008) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20070044 · Cited by 987
Dushyantha, N., Batapola, N., Ilankoon, I. M. S. K., Rohitha, S., Premasiri, R., Abeysinghe, B., Ratnayake, N., & Dissanayake, K. (2020) · Ore Geology Reviews · doi:10.1016/j.oregeorev.2020.103521 · Cited by 687
Reliability of wind turbine subassemblies
Spinato, F., Tavner, P. J., van Bussel, G. J. W., & Koutoulakos, E. (2009) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2008.0060 · Cited by 646
Self-citationThe state of the art of wind energy conversion systems and technologies: A review
Cheng, M., & Zhu, Y. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.08.037 · Cited by 600
Liu, Z., & Zhang, L. (2020) · Measurement · doi:10.1016/j.measurement.2019.107002 · Cited by 535
Overview of control systems for the operation of DFIGs in wind energy applications
Pena, R., Cardenas, R., & Asher, G. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6699116 · Cited by 529
Schubel, P. J., & Crossley, R. J. (2012) · Energies · doi:10.3390/en5093425 · Cited by 510
Permanent Magnet Synchronous Generator-Based Standalone Wind Energy Supply System
Bhende, C. N., Mishra, S., & Malla, S. G. (2011) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2011.2159253 · Cited by 370
Cost-Effective Condition Monitoring for Wind Turbines
Yang, W., Tavner, P. J., Crabtree, C. J., & Wilkinson, M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032202 · Cited by 344
Self-citationLVRT Scheme of PMSG Wind Power Systems Based on Feedback Linearization
Kim, K.-H., Jeung, Y.-C., Lee, D.-C., & Kim, H.-G. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2171999 · Cited by 280
Tjiu, W., Marnoto, T., Mat, S., Ruslan, M. H., & Sopian, K. (2015) · Renewable Energy · doi:10.1016/j.renene.2014.09.038 · Cited by 279
Habib, K., & Wenzel, H. (2014) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2014.04.035 · Cited by 278
Selection guidelines for wind energy technologies
Olabi, A. G., Wilberforce, T., Elsaid, K., Salameh, T., Sayed, E. T., Husain, K. S., & Abdelkareem, M. A. (2021) · Energies · doi:10.3390/en14113244 · Cited by 108
Metadata
- Authors
- Polinder, H., Van Der Pijl, F. F. A., De Vilder, G.-J., & Tavner, P. J.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2006-09
- Volume
- 21
- Issue
- 3
- Pages
- 725-733
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W2162030535
- Cited by
- 1,128
- References
- 0
- FWCI
- 28.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.