The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
LVRT Scheme of PMSG Wind Power Systems Based on Feedback Linearization
Abstract
This paper proposes a low-voltage ride-through scheme for the permanent magnet synchronous generator (PMSG) wind power system at the grid voltage sag. The dc-link voltage is controlled by the generator-side converter instead of the grid-side converter (GSC). Considering the nonlinear relationship between the generator speed ωmand the dc-link voltage Vdc, a dc-link voltage controller is designed using a feedback linearization theory. The GSC controls the grid active power for a maximum power point tracking. The validity of this control algorithm has been verified by simulation and experimental results for a reduced-scale PMSG wind turbine simulator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Slotine, J.-J. E., & Li, W. (1991) · CERN Document Server (European Organization for Nuclear Research) · Cited by 18,975
Linear system theory and design
Barnett, S. M. (1986) · Automatica · doi:10.1016/0005-1098(86)90039-7 · Cited by 3,677
Linear System Theory and Design
Chen, C. (1995) · Medical Entomology and Zoology · Cited by 3,047
Comparison of Direct-Drive and Geared Generator Concepts for Wind Turbines
Polinder, H., Van Der Pijl, F. F. A., De Vilder, G.-J., & Tavner, P. J. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.875476 · Cited by 1,128
Dual current control scheme for PWM converter under unbalanced input voltage conditions
Song, H.-S., & Nam, K. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793344 · Cited by 930
Static synchronous compensators (STATCOM): a review
Singh, B., Saha, R., Chandra, A., & Al‐Haddad, K. (2009) · IET Power Electronics · doi:10.1049/iet-pel.2008.0034 · Cited by 386
DC-bus voltage control of three-phase AC/DC PWM converters using feedback linearization
Lee, D.-C., Lee, G.-M., & Lee, K.-D. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.845058 · Cited by 318
Self-citationControl of a Cascade STATCOM With Star Configuration Under Unbalanced Conditions
Song, Q., & Liu, W. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2009172 · Cited by 235
Foo, G., & Rahman, M. F. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030815 · Cited by 198
Cited by
Stability and Control Aspects of Microgrid Architectures–A Comprehensive Review
Ahmed, M., Meegahapola, L., Vahidnia, A., & Datta, M. (2020) · IEEE Access · doi:10.1109/access.2020.3014977 · Cited by 326
Sliding Mode Control of PMSG Wind Turbine Based on Enhanced Exponential Reaching Law
Mozayan, S. M., Saad, M., Vahedi, H., Fortin-Blanchette, H., & Soltani, M. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2570718 · Cited by 284
Krishnamoorthy, H. S., Rana, D., Garg, P., Enjeti, P. N., & Pitel, I. J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295419 · Cited by 48
Metadata
- Authors
- Kim, K.-H., Jeung, Y.-C., Lee, D.-C., & Kim, H.-G.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-05
- Volume
- 27
- Issue
- 5
- Pages
- 2376-2384
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2100959566
- Cited by
- 280
- References
- 9
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: LVRT Scheme of PMSG Wind Power Systems Based on Feedback Linearization. https://app.cochat.ai/papers/10.1109/tpel.2011.2171999
- The paper
- Kim, K.-H., Jeung, Y.-C., Lee, D.-C., & Kim, H.-G. (2012). LVRT Scheme of PMSG Wind Power Systems Based on Feedback Linearization. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2011.2171999
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.