Design Considerations of Silicon Nanowire Biosensors

Nair, Pradeep R., Alam, Muhammad A.·2007·IEEE Transactions on Electron Devices

Abstract

Biosensors based on silicon nanowires (Si-NWs) promise highly sensitive dynamic label-free electrical detection of biomolecules. Despite the tremendous potential and promising experimental results, the fundamental mechanism of electrical sensing of biomolecules and the design considerations of NW sensors remain poorly understood. In this paper, we discuss the prospects and challenges of biomolecule detection using Si-NW biosensors as a function of device parameters, fluidic environment, charge polarity of biomolecules, etc., and refer to experimental results in literature to support the nonintuitive predictions wherever possible. Our results indicate that the design of Si nanobiosensor is nontrivial and as such, only careful optimization supported by numerical simulation would ensure optimal sensor performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/ted.2007.909059

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 316

Metadata

Authors
Nair, P. R., & Alam, M. A.
Venue
IEEE Transactions on Electron Devices
Published
2007
Volume
54
Issue
12
Pages
3400-3408
ISSN
0018-9383 (ISSN-L)
OpenAlex
W2151385252
Cited by
316
References
28
FWCI
9.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design Considerations of Silicon Nanowire Biosensors. https://app.cochat.ai/papers/10.1109/ted.2007.909059
The paper
Nair, P. R., & Alam, M. A. (2007). Design Considerations of Silicon Nanowire Biosensors. IEEE Transactions on Electron Devices. https://doi.org/10.1109/ted.2007.909059

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.