Analytical Modeling of a Nanogap-Embedded FET for Application as a Biosensor
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
An analytical model of a nanogap-embedded field-effect transistor, which is termed here simply as a biotransistor, is developed in this study. A surface potential model is attained by solving a 2-D Poisson equation with approximation of a parabolic potential profile along the channel depth. The analytical threshold voltage is then derived from the surface potential model to comprise the unique feature of the biotransistor, which acts as a biosensor. A shift of the threshold voltage was used as a metric to ascertain the sensitivity after the biomolecule interacts with the biotransistor. Various device parameters were investigated in the developed analytical model. The characteristic trend is supported and verified via a simulation. Hence, the proposed model can provide a useful guideline for the optimal design and fabrication of a biotransistor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Cited by
Narang, R., Reddy, K. V. S., Saxena, M., Gupta, R. S., & Gupta, M. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2208115 · Cited by 308
“[10] proposed an analytical model for a nanogap-embedded FET biosensor which does not take into consideration the charge possessed by the biomolecule.”
BackgroundComparative analysis of dielectric- modulated FET and TFET-based biosensor
Narang, R., Saxena, M., & Gupta, M. (2015) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2015.2396899 · Cited by 296
“The existing literature available for DM-FET [14] and DMTFET [3] makes use of the simplistic assumption that the com-”
MethodWangkheirakpam, V. D., Bhowmick, B., & Pukhrambam, P. D. (2020) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2020.2969206 · Cited by 199
Dielectric-Modulated Impact-Ionization MOS Transistor as a Label-Free Biosensor
Kannan, N., & Kumar, M. J. (2013) · IEEE Electron Device Letters · doi:10.1109/led.2013.2283858 · Cited by 161
Chakraborty, A., & Sarkar, A. (2017) · Journal of Computational Electronics · doi:10.1007/s10825-017-0999-2 · Cited by 94
Metadata
- Authors
- Choi, J.-M., Han, J.-W., Choi, S.-J., & Choi, Y.-K.
- Venue
- IEEE Transactions on Electron Devices
- Published
- 2010-12
- Volume
- 57
- Issue
- 12
- Pages
- 3477-3484
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W2131041230
- Cited by
- 175
- References
- 3
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.