Modeling of Soft-Switching Losses of IGBTs in High-Power High-Efficiency Dual-Active-Bridge DC/DC Converters
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Soft-switching techniques are very attractive and often mandatory requirements in medium-voltage and medium-frequency applications such as solid-state transformers. The effectiveness of these soft-switching techniques is tightly related to the dynamic behavior of the internal stored charge in the utilized semiconductor devices. For this reason, this paper analyzes the behavior of the internal charge dynamics in high-voltage (HV) semiconductors, giving a clear base to perform overall converter optimizations and to understand the previously proposed zero-current-switching techniques for insulated-gate bipolar-transistor (IGBT)-based resonant dual active bridges. From these previous approaches, the two main concepts that allow switching loss reduction in HV semiconductors are identified: 1) shaping of the conducted current in order to achieve a high recombination time in the previously conducting semiconductors; and 2) achieving zero-voltage-switching (ZVS) in the turning-on device. The means to implement these techniques in a triangular-current-mode dual-active-bridge converter, together with the benefits of the proposed approaches, are analyzed and experimentally verified with a 1.7-kV IGBT-based neutral-point-clamped (NPC) bridge. Additionally, the impact of the modified currents in the converter's performance is quantified in order to determine the benefits of the introduced concepts in the overall converter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, J., Huang, A., Sung, W., Liu, Y., & Baliga, B. (2009) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2009.932583 · Cited by 260 · cited 1×
“These additional functionalities are envisioned as the key enabling features for future compact traction solutions [1], [2], grid integration of renewable energy generation [3]–[5], and smart grid implementation [6], [7], among others.”
BackgroundMedium frequency topology in railway applications
Steiner, M., & Reinold, H. (2007) · 2007 European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417570 · Cited by 249
Cited by
Bosshard, R., Kolar, J. W., Muhlethaler, J., Stevanovic, I., Wunsch, B., & Canales, F. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2311302 · Cited by 411
Self-citationHybrid ac/dc microgrids—Part I: Review and classification of topologies
Unamuno, E., & Barrena, J. A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.194 · Cited by 399
Leibl, M., Ortiz, G., & Kolar, J. W. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2623679 · Cited by 306
Self-citationHossain, M. Z., Rahim, N. A., & Selvaraj, J. A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.017 · Cited by 305
Design and Experimental Testing of a Resonant DC–DC Converter for Solid-State Transformers
Ortiz, G., Leibl, M. G., Huber, J. E., & Kolar, J. W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2637827 · Cited by 143
“frequency and the rather long time constants associated with the stored charge dynamics of IGBT switches in this voltage class [21].”
BackgroundMethodSelf-citationOrtiz, G., Leibl, M., Kolar, J. W., & Apeldoorn, O. (2013) · 2013 IEEE 10th International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2013.6527217 · Cited by 126
“The utilized modulation scheme ensures soft switching of all semiconductor devices by shaping the current to a triangular waveform [9], as shown in Fig.”
MethodSelf-citationNew Bidirectional Intelligent Semiconductor Transformer for Smart Grid Application
Han, B.-M., Choi, N.-S., & Lee, J.-Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2284009 · Cited by 37
Operation of a three phase solid state-Transformer under unbalanced load conditions
Venkat, J., Shukla, A., & Kulkarni, S. V. (2014) · 2014 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES) · doi:10.1109/pedes.2014.7042116 · Cited by 12
Solid state transformer for wind power interfacing
Tom, B. M., & Ashok, S. (2017) · 2017 IEEE International Conference on Signal Processing, Informatics, Communication and Energy Systems (SPICES) · doi:10.1109/spices.2017.8091314 · Cited by 3
Metadata
- Authors
- Ortiz, G., Uemura, H., Bortis, D., Kolar, J. W., & Apeldoorn, O.
- Venue
- IEEE Transactions on Electron Devices
- Published
- 2013-02
- Volume
- 60
- Issue
- 2
- Pages
- 587-597
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W1993447000
- Cited by
- 126
- References
- 2
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).