Temperature-Dependent Thermal Impedance Measurement of GaN-Based HEMTs Using Transient Thermoreflectance
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The transient thermal response of GaN high-electron-mobility transistors (HEMTs) is studied using transient thermal thermoreflectance (TTR) measurements. The change in the thermal impedance at various ambient temperatures is observed and analyzed using finite-element (FE) simulation and thermal equivalent circuits. A temperature-dependent Cauer model has been implemented for predicting the transient temperature response of the device under test (DUT), applicable to arbitrary power dissipations or ambient temperatures. This work provides a practical way for determining or verifying transient thermal models of GaN-based HEMTs using RC networks.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
GaN-Based RF Power Devices and Amplifiers
Mishra, U. K., Likun, S., Kazior, T. E., & Wu, Y.-F. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2007.911060 · Cited by 1,828 · cited 1×
“G aN high-electron-mobilitys transistors (HEMTs) are ideal for high voltage, high current, and high-power density applications [1], [2].”
BackgroundThe 2018 GaN power electronics roadmap
Amano, H., Baines, Y., Beam, E., Borga, M., Bouchet, T., Chalker, P. R., Charles, M., Chen, K. J., Chowdhury, N., Chu, R., et al. (2018) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aaaf9d · Cited by 1,313 · cited 1×
“G aN high-electron-mobilitys transistors (HEMTs) are ideal for high voltage, high current, and high-power density applications [1], [2].”
BackgroundSelf-citationA new evaluation method of thermal transient measurement results
Székely, V. (1997) · Microelectronics Journal · doi:10.1016/s0026-2692(96)00031-6 · Cited by 430 · cited 2×
“To acquire a network with physical meaning, one can transform the Foster into an equivalent Cauer network using the method described in [24].”
BackgroundMethodManoi, A., Pomeroy, J. W., Killat, N., & Kuball, M. (2010) · IEEE Electron Device Letters · doi:10.1109/led.2010.2077730 · Cited by 194 · cited 1×
“…Raman measured GaN channel temperature, and EOC temperatures were used to adjust unknown parameters in this order: 1) chuck/flange thermal interface resistance; 2) die attach thermal conductivity; and 3) effective thermal boundary resistances (TBR eff ) between the GaN layer and substrate [20].”
MethodSelf-citationThermal conductivity of GaN, GaN71 , and SiC from 150 K to 850 K
Zheng, Q., Li, C., Rai, A., Leach, J. H., Broido, D. A., & Cahill, D. G. (2019) · Physical Review Materials · doi:10.1103/physrevmaterials.3.014601 · Cited by 177
Kuball, M., & Pomeroy, J. W. (2016) · IEEE Transactions on Device and Materials Reliability · doi:10.1109/tdmr.2016.2617458 · Cited by 170 · cited 2×
“There are well-established methods for determining the steady-state thermal resistance of GaN HEMTs, using sub-micrometer spatial resolution temperature measurements combined with thermal simulation [7].”
BackgroundMethodSelf-citationKaloyeros, A. E., Pan, Y., Goff, J., & Arkles, B. (2020) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/aba447 · Cited by 164 · cited 1×
“For a thermal conductivity of 1 W/m · K, the minimum possible for Si 3 N 4 [23], the temperature difference between the SFP surface and GaN is a constant 5.3 C after 5 µ s and is independent of the Si 3 N 4 thermal conductivity according to the simulation.”
MethodInfluentialTadjer, M. J., Anderson, T. J., Ancona, M. G., Raad, P. E., Komarov, P. L., Bai, T., Gallagher, J. C., Koehler, A. D., Goorsky, M. S., Francis, D. A., et al. (2019) · IEEE Electron Device Letters · doi:10.1109/led.2019.2909289 · Cited by 117 · cited 1×
“Power densities up to 56 W have been reported for GaN-based HEMTs [3] which, without appropriate thermal management, can result in excessive channel temperatures and accelerating device degradation [4], [5], [6].”
BackgroundOperating channel temperature in GaN HEMTs: DC versus RF accelerated life testing
Pomeroy, J. W., Uren, M. J., Lambert, B., & Kuball, M. (2015) · Microelectronics Reliability · doi:10.1016/j.microrel.2015.09.025 · Cited by 79 · cited 1×
“In the model power is dissipated in a 0.5-µ m-long volume adjusted to the drain edge of each gate foot, with a depth of 50 nm, representing the size of the Joule self-heating region [19].”
MethodInfluentialSelf-citationHeat capacity ofα−GaN: Isotope effects
Kremer, R. K., Cardona, M., Schmitt, E., Blumm, J., Estreicher, S. K., Sanati, M., Bockowski, M., Grzegory, I., Suski, T., & Jezowski, A. (2005) · Physical Review B · doi:10.1103/physrevb.72.075209 · Cited by 72
Cited by
Han, G., Kim, J., Park, S., & Bae, W. (2025) · Electronics · doi:10.3390/electronics14214193 · Cited by 34
“Analytical methods such as coupled electro-thermal analysis, lumped thermal models (LTM), and the finite element method (FEM) are used to predict T j and identify hotspots [64,68–70].”
Emerging thermal metrology for ultra-wide bandgap semiconductor devices
Myren, D., Vásquez, F., Lundh, J. S., Tadjer, M. J., & Pavlidis, G. (2025) · Applied Physics Letters · doi:10.1063/5.0256723 · Cited by 13
Formicone, G. F., Walker, J., Pomeroy, J. W., & Kuball, M. (2024) · European Microwave Integrated Circuits Conference · doi:10.23919/eumic61603.2024.10732141 · Cited by 5
“Known temperature dependent thermal conductivities were assigned to each material in the model [4].”
MethodSelf-citationNumerical Modeling of Dynamic Thermal Coupling in GaN HEMTs Calibrated by Transient Measurements
Kristensen, T., Nilsson, T. M. J., Divinyi, A., Bremer, J., & Thorsell, M. (2024) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2024.3478180 · Cited by 3
Zhang, Y., Huang, J., Zhou, L. Y., Ma, X., & Li, M. (2025) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2025.3643417 · Cited by 3
Metadata
- Authors
- Zheng, X., Pomeroy, J. W., Jindal, G., & Kuball, M.
- Affiliations
- University of Bristol (GB)
- Venue
- IEEE Transactions on Electron Devices
- Published
- 2024-04
- Volume
- 71
- Issue
- 4
- Pages
- 2367-2372
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W4392152226
- Cited by
- 21
- References
- 24
- Citations by year
- 2026: 10 · 2025: 9 · 2024: 2
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- Licence
- Locations
- IEEE Transactions on Electron Devices (publishedVersion)
- Explore Bristol Research (publishedVersion, cc-by)
- Bristol Research (University of Bristol) (acceptedVersion, cc-by)
- Funders
- ULTRA, an Energy Frontier Research Center
- U.S. Department of Energy, Office of Science, Basic Energy Sciences (DE-SC0021230)
- Royal Academy of Engineering through the Chair in Emerging Technologies Scheme
- Topics
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › GaN-based semiconductor devices and materials
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
- Keywords
- GaN high electron mobility transistors, thermal impedance, transient thermoreflectance, transient thermal response, power dissipation, finite element analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temperature-Dependent Thermal Impedance Measurement of GaN-Based HEMTs Using Transient Thermoreflectance. https://app.cochat.ai/papers/10.1109/ted.2024.3367309
- The paper
- Zheng, X., Pomeroy, J. W., Jindal, G., & Kuball, M. (2024). Temperature-Dependent Thermal Impedance Measurement of GaN-Based HEMTs Using Transient Thermoreflectance. IEEE Transactions on Electron Devices. https://doi.org/10.1109/ted.2024.3367309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.