Assessment of Human Exposure to Electromagnetic Fields: Review and Future Directions
Open accessThe DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Abstract
This article reviews recent standardization activities and scientific studies related to the assessment of human exposure to electromagnetic fields (EMF). The differences of human exposure standards and assessment of consumer products and medical applications are summarized. First, we reviewed human body modeling and tissue dielectric properties. Then, we explain the rationale of current exposure standards from the viewpoint of EMF and the standardization process for product compliance based on these exposure standards. The assessment of wireless power transfer, as an example of emerging wireless devices, and environmental EMFs in our daily lives are reviewed. Safety in magnetic resonance systems, where the EMF exposure is much larger than from typical consumer devices, is also reviewed. Finally, we summarize future research directions and research needs for EMF safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332 · cited 1×
“Recent developments in artificial intelligence, particularly deep learning, has led to remarkable breakthroughs in several medical imaging and signal processing applications [20].”
Resonance Absorption by Nuclear Magnetic Moments in a Solid
Purcell, E. M., Torrey, H. C., & Pound, R. V. (1946) · Physical Review · doi:10.1103/physrev.69.37 · Cited by 6,053 · cited 1×
“First described experimentally in 1946 [114], MRI has become ‘ the ’ diagnostic imaging tool with over 100 million examinations performed worldwide in 2020 [115].”
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270 · cited 2×
“Conventionally, tissue conductivity values have been estimated based on data from animal tissue measurements [23].”
Thermal dose determination in cancer therapy
Sapareto, S. A., & Dewey, W. C. (1984) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(84)90379-1 · Cited by 2,498 · cited 1×
“Because tissue damage not only depends on the tissue temperature increase but also on the exposure time, the transient temperature increases are translated into an effective thermal load by applying the thermal dose model of cumulative equivalent minutes at 43 °C (CEM43) [128].”
GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING ELECTRIC AND MAGNETIC FIELDS (1 Hz TO 100 kHz)
(2010) · Health Physics · doi:10.1097/hp.0b013e3181f06c86 · Cited by 2,164 · cited 5×
“This leakage in the neighborhood environment has increased the need to determine compliance of WPT systems with the EMC and safety standards [1], [2], [33].”
InfluentialGuidelines for Limiting Exposure to Electromagnetic Fields (100 kHz to 300 GHz)
(2020) · Health Physics · doi:10.1097/hp.0000000000001210 · Cited by 2,081 · cited 1×
“International Commission on Non-Ionizing Radiation Protection (ICNIRP), set safety guidelines/standards to protect people from excessive exposure to EMF [1-3].”
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439
Self-citationLin, J., Saunders, R. A., Schulmeister, K., Söderberg, P. G., Stuck, B. E., Swerdlow, A. J., Taki, M., Veyret, B., Ziegelberger, G., Repacholi, M. H., et al. (2010) · HAL · Cited by 1,261
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103 · cited 1×
“Earlier attempts for anthropomorphic human models, as in [8] consisted of 36 organs/tissues in 1 mm image resolution; however, the longitudinal resolution was low at 5–10 mm.”
Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774
Metadata
- Authors
- Hirata, A., Diao, Y., Onishi, T., Sasaki, K., Ahn, S., Colombi, D., De Santis, V., Laakso, I., Giaccone, L., Wout, J., Rashed, E., Kainz, W., & Chen, J.
- Venue
- IEEE Transactions on Electromagnetic Compatibility
- Published
- 2021-10
- Volume
- 63
- Issue
- 5
- Pages
- 1619-1630
- ISSN
- 0018-9375 (ISSN-L)
- 1558-187X
- OpenAlex
- W3202198480
- Cited by
- 161
- References
- 87
- FWCI
- 11.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Human Exposure to Electromagnetic Fields: Review and Future Directions. https://app.cochat.ai/papers/10.1109/temc.2021.3109249
- The paper
- Hirata, A., Diao, Y., Onishi, T., Sasaki, K., Ahn, S., Colombi, D., De Santis, V., Laakso, I., Giaccone, L., Wout, J., Rashed, E., Kainz, W., & Chen, J. (2021). Assessment of Human Exposure to Electromagnetic Fields: Review and Future Directions. IEEE Transactions on Electromagnetic Compatibility. https://doi.org/10.1109/temc.2021.3109249
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.