Permanent-Magnet Brushless Machines With Unequal Tooth Widths and Similar Slot and Pole Numbers
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
This paper presents a comparative study of three-phase permanent-magnet brushless machines in which the slot and pole numbers are similar, with reference to conventional brushless dc machines in which the ratio of the slot number to pole number is usually 3 : 2. Three different motor designs are considered. Two have equal tooth widths, with one having a coil wound on every tooth and the other only having a coil wound on alternate teeth, while the third machine also has coils wound on alternate teeth but these are wider than the unwound teeth while the width of their tooth tips is almost equal to the rotor pole pitch in order to maximize the flux linkage and torque. Analytical and finite-element methods are employed to predict the flux-linkage and back-electromotive-force waveforms, and the self- and mutual-inductances, and these are shown to be in good agreement with measured results. It is also shown that the third machine is eminently appropriate for brushless dc operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis of high performance PM motors with concentrated windings
Cros, J., & Viarouge, P. (2002) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2002.1009476 · Cited by 667 · cited 1×
“making the tooth tips of the wound teeth span approximately one pole pitch, is investigated [7], [8].”
BackgroundZhu, Z. Q., Howe, D., & Chan, C. C. (2002) · IEEE Transactions on Magnetics · doi:10.1109/20.990112 · Cited by 492 · cited 2×
“where ( ) r Bn depends on the pole number, the stator bore radius, the rotor outer radius and the magnet inner radius, as well as the harmonic orders, and ( ) θ λrel is the relative permeance function [11].”
BackgroundSelf-citationFault-tolerant permanent magnet machinedrives
Mecrow, B. C., Jack, A. G., Haylock, J. A., & Coles, J. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960796 · Cited by 376 · cited 1×
“Further, developments for safety critical applications, such as flight control surface actuation in ‘moreelectric’ aircraft, have resulted in machines with a high degree of fault tolerance [3, 4, 5].”
BackgroundJack, A. G., Mecrow, B. C., & Haylock, J. A. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.511646 · Cited by 368
Jack, A. G., Mecrow, B. C., & Haylock, J. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530372 · Cited by 306 · cited 1×
“Further, developments for safety critical applications, such as flight control surface actuation in ‘moreelectric’ aircraft, have resulted in machines with a high degree of fault tolerance [3, 4, 5].”
BackgroundMulti-phase fault-tolerant brushless DC motor drives
Gopalarathnam, T., Toliyat, H. A., & Moreira, J. C. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2000.882107 · Cited by 91
Design variants of modular permanent magnet brushless machine
Ede, J. D., Atallah, K., & Howe, D. (2002) · Journal of Applied Physics · doi:10.1063/1.1452669 · Cited by 18 · cited 1×
“Such machines, in addition to having a higher number of phases, only have alternate teeth wound, and are often referred to as modular permanent magnet machines [6], and make it easier to realize a high per-unit selfinductance.”
BackgroundSelf-citation
Cited by
Electrical Machines and Drives for Electric, Hybrid, and Fuel Cell Vehicles
Zhu, Z. Q., & Howe, D. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2006.892482 · Cited by 1,547
Self-citationEL-Refaie, A. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030211 · Cited by 1,373
Comparison of PM brushless motors, having either all teeth or alternate teeth wound
Ishak, D., Zhu, Z. Q., & Howe, D. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.853765 · Cited by 231
“DUE to their short end-windings, it is often advantageous for permanent magnet brushless machines to employ a concentrated winding, since they generally exhibit a lower copper loss and a higher efficiency, as well as a higher power density [1]–[8].”
BackgroundSelf-citation
Metadata
- Authors
- Ishak, D., Zhu, Z. Q., & Howe, D.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2005-03
- Volume
- 41
- Issue
- 2
- Pages
- 584-590
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2111225396
- Cited by
- 195
- References
- 7
- FWCI
- 10.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.