A New Approach for Current Sensor Fault Diagnosis in PMSG Drives for Wind Energy Conversion Systems
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Fault diagnosis is a mandatory feature in fault-tolerant systems, since it provides the information necessary for the fault isolation and system reconfiguration. Recently, permanent-magnet synchronous generator (PMSG) drives have achieved prominence in wind energy conversion systems (WECSs), due to their reliability and availability. In this paper, a new approach is proposed for current sensor fault diagnosis in PMSG drives for WECSs. As opposed to the conventional state-observer-based methods for current sensor faults, which require a system model and the respective parameters, the proposed diagnostic method uses the measured phase currents only. Thus, its main merits are simplicity and reliability in the diagnosis, making it suitable for real-time implementation and to trigger remedial procedures. In addition, current sensor and open-circuit faults can be distinguished, and the affected phase is effectively identified in both cases. The proposed diagnostic technique is applied to the two power converters of a conventional back-to-back topology, and its performance is analyzed by means of several experimental results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The method proposed in [288] (for PM synchronous generator) and in [289] (for PMSM) uses average normalized current values, but it is limited to failure of one of the three CSs present in the drive system.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [288]
Citations
Cites
A strategy for improving reliability of field-oriented controlled induction motor drives
Liu, T.-H., Fu, J.-R., & Lipo, T. A. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.245714 · Cited by 374
Foo, G. H. B., Zhang, X., & Vilathgamuwa, D. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2244537 · Cited by 369
A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298
Self-citationOpen-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications
Freire, N. M. A., Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2207655 · Cited by 277
Self-citationNajafabadi, T. A., Salmasi, F. R., & Jabehdar-Maralani, P. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2055775 · Cited by 250
Jeong, Y.-S., Sul, S.-K., Schulz, S. E., & Patel, N. R. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.840947 · Cited by 240
Analysis and compensation of current measurement error in vector-controlled AC motor drives
Chung, D.-W., & Sul, S.-K. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.663477 · Cited by 218
Easy and Fast Sensor Fault Detection and Isolation Algorithm for Electrical Drives
Berriri, H., Naouar, M. W., & Slama-Belkhodja, I. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2140333 · Cited by 197
Doubly Fed Induction Generator Model-Based Sensor Fault Detection and Control Loop Reconfiguration
Rothenhagen, K., & Fuchs, F. W. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2013683 · Cited by 157
Design of a Fault-Tolerant Controller Based on Observers for a PMSM Drive
Akrad, A., Hilairet, M., & Diallo, D. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2050756 · Cited by 155
Current Sensor Fault Detection, Isolation, and Reconfiguration for Doubly Fed Induction Generators
Rothenhagen, K., & Fuchs, F. W. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017562 · Cited by 152
Analysis and compensation of current measurement error in vector controlled AC motor drives
Chung, D.-W., Sul, S.-K., & Lee, D.-C. (1996) · IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting · doi:10.1109/ias.1996.557053 · Cited by 136
Diminution of Current-Measurement Error for Vector-Controlled AC Motor Drives
Jung, H.-S., Hwang, S.-H., Kim, J.-M., Kim, C.-U., & Choi, C. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.880904 · Cited by 130
A wavelet-based approach to abrupt fault detection and diagnosis of sensors
Zhang, H. Q., & Yan, Y. (2001) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.963215 · Cited by 116
Instrument fault detection and isolation: state of the art and new research trends
Betta, G., & Pietrosanto, A. (2000) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.836318 · Cited by 110
Tabbache, B., Benbouzid, M. E. H., Kheloui, A., & Bourgeot, J.-M. (2013) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2012.2230200 · Cited by 102
Instrument fault detection and isolation: state of the art and new research trends
Betta, G., & Pietrosanto, A. (2002) · Conference proceedings - IEEE Instrumentation/Measurement Technology Conference · doi:10.1109/imtc.1998.679833 · Cited by 96
Current Sensor Fault-Tolerant Control for WECS With DFIG
Karimi, S., Gaillard, A., Poure, P., & Saadate, S. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031193 · Cited by 82
A DC Voltage Monitoring and Control Method for Three-Phase Grid-Connected Wind Turbine Inverters
Wang, Z., & Chang, L. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921174 · Cited by 58
Field programmable gate array-based fault-tolerant hysteresis current control for AC machine drives
Berriri, H., Naouar, W., Bahri, I., Slama-Belkhodja, I., & Monmasson, E. (2012) · IET Electric Power Applications · doi:10.1049/iet-epa.2011.0053 · Cited by 44
Cited by
Deep Learning Based Approach for Bearing Fault Diagnosis
He, M., & He, D. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2661250 · Cited by 484
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
Self-citationGou, B., Xu, Y., Xia, Y., Deng, Q., & Ge, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2994351 · Cited by 211
Chakraborty, C., & Verma, V. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2345337 · Cited by 209
Metadata
- Authors
- Freire, N. M. A., Estima, J. O., & Cardoso, A. J. M.
- Affiliations
- University of Coimbra (PT)
- University of Beira Interior (PT)
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2014-03
- Volume
- 50
- Issue
- 2
- Pages
- 1206-1214
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2061487652
- Cited by
- 115
- References
- 20
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 13 · 2023: 10 · 2022: 5 · 2021: 10 · 2020: 7 · 2019: 7 · 2018: 10 · 2017: 14 · 2016: 14 · 2015: 8 · 2014: 7
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Funders
- Portuguese Foundation for Science and Technology (SFRH/BD/40286/2007, PTDC/EEA-EEL/114846/2009, SFRH/BD/70868/2010)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- permanent magnet synchronous generator, wind energy conversion system, fault-tolerant systems, open-circuit fault, current sensor fault, phase current measurement, back-to-back converter, fault isolation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.