Leakage Inductance Calculation for Planar Transformers With a Magnetic Shunt
Open accessThe DOI matches its Crossref record.
Abstract
The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance, which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the finite-element analysis simulation and the experimental results have proven the validity of the proposed calculation method for leakage inductance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
800-V Electric Vehicle Powertrains: Review and Analysis of Benefits, Challenges, and Future Trends
Aghabali, I., Bauman, J., Kollmeyer, P. J., Wang, Y., Bilgin, B., & Emadi, A. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3044938 · Cited by 434
Li, B., Li, Q., & Lee, F. C. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2874806 · Cited by 211
LLC Converters With Planar Transformers: Issues and Mitigation
Saket, M. A., Shafiei, N., & Ordonez, M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2602360 · Cited by 210
Zhang, Z., Liu, C., Wang, M., Si, Y., Liu, Y., & Lei, Q. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2980313 · Cited by 137
High Efficiency Integrated Transformer Design in DAB Converters for Solid-State Transformers
Lee, E. S., Park, J. H., Kim, M. Y., & Lee, J. S. (2022) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2022.3168561 · Cited by 63
Metadata
- Authors
- Zhang, J., Ouyang, Z., Duffy, M. C., Andersen, M. A. E., & Hurley, W. G.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2014-11
- Volume
- 50
- Issue
- 6
- Pages
- 4107-4112
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2316013081
- Cited by
- 116
- References
- 0
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Leakage Inductance Calculation for Planar Transformers With a Magnetic Shunt. https://app.cochat.ai/papers/10.1109/tia.2014.2322140
- The paper
- Zhang, J., Ouyang, Z., Duffy, M. C., Andersen, M. A. E., & Hurley, W. G. (2014). Leakage Inductance Calculation for Planar Transformers With a Magnetic Shunt. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2014.2322140
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.