Interleaved SEPIC Power Factor Preregulator Using Coupled Inductors In Discontinuous Conduction Mode With Wide Output Voltage
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A power factor preregulator (PFP) usually serves as the first stage of an active two-stage ac/dc converter in a variety of applications including inductive heating systems, wireless charging systems, and onboard chargers for plug-in electric vehicles. Conventionally, boost-type PFPs are utilized to regulate the dc-link voltage at a fixed voltage; however, a variable dc-link voltage can enhance the overall efficiency of the converters. In this paper, an interleaved single-ended primary inductor converter (SEPIC) with coupled inductors is proposed as the PFP stage for two-stage ac/dc converters. The converter is designed to operate in discontinuous conduction mode in order to achieve soft switching for switches and diodes. The directly coupled inductors are utilized to reduce the number of magnetic components and decrease the input current ripple. A 500-W interleaved SEPIC PFP prototype is designed to verify the benefits of this converter. The experimental results show that the converter can maintain high efficiency over a wide range of dc-link voltage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Review of Three-Phase Improved Power Quality AC–DC Converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825341 · Cited by 1,728
A review of single-phase improved power quality ac~dc converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2003) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.817609 · Cited by 1,297
Khaligh, A., & Dusmez, S. (2012) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2012.2213104 · Cited by 630
Self-citationAn LLC Resonant DC–DC Converter for Wide Output Voltage Range Battery Charging Applications
Musavi, F., Craciun, M., Gautam, D. S., Eberle, W., & Dunford, W. G. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2241792 · Cited by 498
Cited by
A 300-kHz 6.6-kW SiC Bidirectional LLC Onboard Charger
Li, H., Zhang, Z., Wang, S., Tang, J., Ren, X., & Chen, Q. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2910048 · Cited by 237
Shi, C., Tang, Y., & Khaligh, A. (2017) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2017.2729345 · Cited by 187
“Typically, a charger consists of two stages: an acdc stage for rectification of grid ac voltage and power factor correction (PFC) and a dc-dc stage for battery current and voltage regulation [7]–[9].”
Self-citationA Three-Phase Integrated Onboard Charger for Plug-In Electric Vehicles
Shi, C., Tang, Y., & Khaligh, A. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2727398 · Cited by 159
“The add-on threephase interface of the proposed three-phase integrated charger has comparable size to that of a conventional single-phase onboard charger but significantly smaller size than the offboard charger due to no bulky add-on passive components for energy storage and no second-stage dc–dc converter [23], [24].”
MethodSelf-citation
Metadata
- Authors
- Shi, C., Khaligh, A., & Wang, H.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2016-07
- Volume
- 52
- Issue
- 4
- Pages
- 3461-3471
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2341837216
- Cited by
- 84
- References
- 4
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.