Demagnetization Modeling and Fault Diagnosing Techniques in Permanent Magnet Machines Under Stationary and Nonstationary Conditions: An Overview
The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
Permanent magnet (PM) machines are widely used in industrial processes due to their merits such as high power density and torque and low losses (high efficiency). These machines operate frequently under harsh conditions; therefore, they expose different types of faults. These faults can be diagnosed in initial stages using different techniques and prevent the faults' progress to catastrophic stages. One of the most important PM machine faults in terms of occurrence rate is demagnetization fault, whose causes can be heat, electrical, environmental or combinations. This may lead to efficiency drop, poor performance, and low reliability of the system. This paper attempts to review and summarize the demagnetization fault diagnosis methods in PM machines. First the fault generating factors and their impacts on the performance of the motor are discussed. Then, the recently developed techniques for demagnetization fault under stationary and nonstationary conditions in two separate sections are addressed. Presented methods are compared; their weaknesses and strengths are noted. Finally, suggestions for further research are proposed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the visibility of this symptom is strongly dependent on the configuration of the winding, and sometimes even in the case of demagnetization there are no harmonics or subharmonics other than those that occur in a healthy motor due to the natural existing asymmetries of the machine [19], [29], [84], [85].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [29]
In the citing paper
“This drawback can be eliminated by using the flux-based and BEMF methods which are capable of detecting both uniform and local demagnetization [15], [19], [29], [30], [32].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [29]
In the citing paper
“Moreover, as results from the dependence (3), other motor damages depending on the rotational speed, such as ITSCs (see (1)) and mechanical damages such as dynamic eccentricity, can be identified by the same frequencies in the stator currents [29], [32].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [29]
In the citing paper
“The use of BEMF analysis is characterized by the lack of robustness to temperature changes of PMs [3], but the method is simple to implement [29], [95].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [29]
Citations
Cites
A review on empirical mode decomposition in fault diagnosis of rotating machinery
Lei, Y., Lin, J., He, Z., & Zuo, M. J. (2013) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2012.09.015 · Cited by 1,886
Current Signature Analysis to Detect Induction Motor Faults
Thomson, W. T., & Fenger, M. (2001) · IEEE Industry Applications Magazine · doi:10.1109/2943.930988 · Cited by 1,139
Permanent Magnet Synchronous and Brushless DC Motor Drives
Krishnan, R. (2017) · CRC Press eBooks · doi:10.1201/9781420014235 · Cited by 1,114
Permanent magnet motor technology : design and applications
Gieras, J. F., & Wing, M. (1996) · Thammasat University Digital Collections · Cited by 746
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Methods of Motor Current Signature Analysis
Kliman, G. B., & Stein, J. (1992) · Electric Machines & Power Systems · doi:10.1080/07313569208909609 · Cited by 330
Da, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303
Detecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274
Ruoho, S., Kolehmainen, J., Ikaheimo, J., & Arkkio, A. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2033592 · Cited by 264
Espinosa, A. G., Rosero, J. A., Cusido, J., Romeral, L., & Ortega, J. A. (2010) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2009.2037922 · Cited by 243
Ruiz, J.-R. R., Rosero, J. A., Espinosa, A. G., & Romeral, L. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2015942 · Cited by 231
Hong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219
Kim, K.-C., Lim, S.-B., Koo, D.-H., & Lee, J. (2006) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2006.879077 · Cited by 191
Urresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181 · cited 3×
“In [37], it has been shown that for a PMSM with symmetrical concentrated windings harmonic components of induced voltage appear in each series coil, but these harmonics cancel each other in the whole winding.”
Advanced Induction Motor Rotor Fault Diagnosis Via Continuous and Discrete Time–Frequency Tools
Pons-Llinares, J., Antonino-Daviu, J. A., Riera-Guasp, M., Bin Lee, S., Kang, T.-J., & Yang, C. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2355816 · Cited by 180
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177 · cited 1×
“However, these methods need longer computational time compared with other data-based models [21].”
Torregrossa, D., Khoobroo, A., & Fahimi, B. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2151810 · Cited by 169
Rajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
Electric Machines: Modeling, Condition Monitoring, and Fault Diagnosis
Toliyat, H. A., Nandi, S., Choi, S., & Kelk, H. M. (2012) · CRC Press eBooks · doi:10.1201/b13008 · Cited by 162
Nonstationary Motor Fault Detection Using Recent Quadratic Time–Frequency Representations
Rajagopalan, S., Restrepo, J. A., Aller, J. M., Habetler, T. G., & Harley, R. G. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.921431 · Cited by 161
Shen, J., Zhu, Z. Q., & Howe, D. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.836157 · Cited by 155
A Back-emf Based Method to Detect Magnet Failures in PMSMs
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2207731 · Cited by 151 · cited 1×
“k is called fault severity index measurable using ZSVC method as follows [48]:”
MethodStrangas, E. G., Aviyente, S., & Zaidi, S. S. H. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007529 · Cited by 148
Detection of Rotor Faults in Brushless DC Motors Operating Under Nonstationary Conditions
Rajagopalan, S., Aller, J. M., Restrepo, J. A., Habetler, T. G., & Harley, R. G. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.882613 · Cited by 143
Pons-Llinares, J., Antonino-Daviu, J. A., Riera-Guasp, M., Pineda-Sanchez, M., & Climente-Alarcon, V. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2081955 · Cited by 142
Rajagopalan, S., Aller, J. M., Restrepo, J. A., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.894699 · Cited by 142
Discernment of Broken Magnet and Static Eccentricity Faults in Permanent Magnet Synchronous Motors
Goktas, T., Zafarani, M., & Akin, B. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2015.2512602 · Cited by 140
Induction Motor Diagnosis by Advanced Notch FIR Filters and the Wigner–Ville Distribution
Climente-Alarcón, V., Daviu, J. A. A., Riera‐Guasp, M., & Vlček, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2286581 · Cited by 130
Demagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview
Faiz, J., & Nejadi-Koti, H. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2480379 · Cited by 119 · cited 1×
“In [9] and [10], these techniques have been reviewed concentrating on PM synchronous motors (PMSM), but other types of PM machines have not been taken into account.”
Self-citationYılmaz, M. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.033 · Cited by 114
McFarland, J. D., & Jahns, T. M. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2294997 · Cited by 105
Fault Analysis of a PM Brushless DC Motor Using Finite Element Method
Dai, M., Keyhani, A., & Sebastian, T. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.841516 · Cited by 100
Automated Monitoring of Magnet Quality for Permanent-Magnet Synchronous Motors at Standstill
Hong, J., Hyun, D., Lee, S. B., Yoo, J.-Y., & Lee, K.-W. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2049811 · Cited by 100
Improved Sensorless Control of Permanent-Magnet Synchronous Machine Based on Third-Harmonic Back EMF
Liu, J. M., & Zhu, Z. Q. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2284299 · Cited by 98
Moosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.04.062 · Cited by 96
Demagnetization Fault Diagnosis in Surface Mounted Permanent Magnet Synchronous Motors
Ebrahimi, B. M., & Faiz, J. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2217978 · Cited by 95 · cited 7×
“Time delay embedding (TDE) is one of these methods that is able to detect hidden patterns in the (torque) time series data.”
InfluentialSelf-citationPrieto, M. D., Espinosa, A. G., Ruiz, J.-R. R., Urresty, J. C., & Ortega, J. A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066538 · Cited by 95
Farooq, J., Srairi, S., Djerdir, A., & Miraoui, A. (2006) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2006.870936 · Cited by 94
Automated Detection of Rotor Faults for Inverter-Fed Induction Machines Under Standstill Conditions
Kim, B., Lee, K., Yang, J., Lee, S. B., Wiedenbrug, E. J., & Shah, M. R. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2090931 · Cited by 82
Reigosa, D., Fernández, D., Zhu, Z. Q., & Briz, F. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2437975 · Cited by 81
Finite-Element Analysis of the Demagnetization of IPM-Type BLDC Motor With Stator Turn Fault
Lee, Y., Kim, K., & Hur, J. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2283498 · Cited by 81
Ajily, E., Ardebili, M. A. H., & Abbaszadeh, K. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2015.2506819 · Cited by 77
Partial Demagnetization of Permanent Magnets in Electrical Machines Caused by an Inclined Field
Ruoho, S., & Arkkio, A. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.921951 · Cited by 76
Magnets faults characterization for Permanent Magnet Synchronous Motors
Casadei, D., Filippetti, F., Rossi, C., & Stefani, A. (2009) · 2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2009.5292770 · Cited by 74
Ishikawa, T., Seki, Y., & Kurita, N. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2243135 · Cited by 73
Yang, Z., Shi, X., & Krishnamurthy, M. (2014) · 2014 IEEE Transportation Electrification Conference and Expo (ITEC) · doi:10.1109/itec.2014.6861774 · Cited by 72
Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines
Rosero, J. A., Cusido, J., Garcia, A., Ortega, J. A., & Romeral, L. (2006) · IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics · doi:10.1109/iecon.2006.347598 · Cited by 67
2-D Analytical Subdomain Model of a Slotted PMSM With Shielding Cylinder
Hannon, B., Sergeant, P., & Dupré, L. R. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2309325 · Cited by 66
Rotor demagnetization effects on permanent magnet synchronous machines
Ruschetti, C. R., Verucchi, C., Bossio, G. R., Angelo, C. H. D., & García, G. O. (2013) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.05.001 · Cited by 64
Shaft Trajectory Analysis in a Partially Demagnetized Permanent-Magnet Synchronous Motor
Urresty, J.-C., Atashkhooei, R., Riba, J.-R., Romeral, L., & Royo, S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2213565 · Cited by 62
Anisotropic fracture behavior of sintered rare-earth permanent magnets
Li, W., Li, A., & Wang, H. (2005) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2005.852948 · Cited by 58
Analytical Modeling Approach to Detect Magnet Defects in Permanent-Magnet Brushless Motors
Farooq, J. A., Djerdir, A., & Miraoui, A. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.2001751 · Cited by 58
Reluctance network modelling of surface permanent magnet motor considering iron nonlinearities
Raminosoa, T., Farooq, J. A., Djerdir, A., & Miraoui, A. (2009) · Energy Conversion and Management · doi:10.1016/j.enconman.2009.01.012 · Cited by 56
Ruiz, J.-R. R., Garcia Espinosa, A., Romeral, L., & Cusidó, J. (2010) · Electric Power Systems Research · doi:10.1016/j.epsr.2010.04.010 · Cited by 51
Urresty, J.-C., Riba, J.-R., Romeral, L., & Garcia, A. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2062529 · Cited by 51
De Bisschop, J., Abouelyazied, A., Sergeant, P., & Dupré, L. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2316851 · Cited by 47
Demagnetization fault diagnosis method for PMSM of electric vehicle
Lee, J., Jeon, Y.-J., Choi, D.-C., Kim, S., & Kim, S. W. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6699559 · Cited by 45
Rajagopalan, S., Restrepo, J. A., Aller, J. M., Habetler, T. G., & Harley, R. G. (2005) · 2005 5th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2005.4662511 · Cited by 42
Gritli, Y., Rossi, C., Casadei, D., Zarri, L., & Filippetti, F. (2012) · 2012 XXth International Conference on Electrical Machines · doi:10.1109/icelmach.2012.6350219 · Cited by 38
Detection and estimation of demagnetization faults in permanent magnet synchronous motors
Chakraborty, S., Keller, E., Ray, A., & Mayer, J. (2012) · Electric Power Systems Research · doi:10.1016/j.epsr.2012.11.005 · Cited by 37
Rezig, A., Mekideche, M. R., & Djerdir, A. (2011) · Journal of Electrical Engineering and Technology · doi:10.5370/jeet.2011.6.3.356 · Cited by 37
Kim, H.-K., Kang, D.-H., & Hur, J. (2015) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2439716 · Cited by 36
Khoobroo, A., & Fahimi, B. (2010) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2010.5433547 · Cited by 36
Demagnetization Testing for a Mixed-Grade Dovetail Permanent-Magnet Machine
Ruoho, S., Kolehmainen, J., Ikäheimo, J., & Arkkio, A. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2019955 · Cited by 28
Zafarani, M., Göktaş, T., Akin, B., & Fedigan, S. E. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2561900 · Cited by 28
Quality Assurance Testing for Magnetization Quality Assessment of BLDC Motors Used in Compressors
Lee, K.-W., Hong, J., Lee, S. B., & Lee, S. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2075732 · Cited by 27
A comprehensive analysis of magnet defect faults in permanent magnet synchronous motors
Zafarani, M., Göktaş, T., & Akin, B. (2015) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2015.7104743 · Cited by 24
Demagnetization faults analysis in a BLDC motor for diagnostic purposes
Athanasopoulos, D. K., Karagkounis, P. D., Kappatou, J. C., & Tsotoulidis, S. (2014) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2014.6960437 · Cited by 24
Inverse transform method for magnet defect diagnosis in permanent magnet machines
Abbaszadeh, K., Saied, S., Hemmati, S., & Tenconi, A. (2014) · IET Electric Power Applications · doi:10.1049/iet-epa.2013.0176 · Cited by 19
Behavior of a five-phase surface-mounted permanent magnet motor under magnet demagnetization
Casadei, D., Mengoni, M., Serra, G., Tani, A., & Zarri, L. (2011) · 8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives · doi:10.1109/demped.2011.6063634 · Cited by 18
Brela, M., Michalski, M., Gebhardt, H.-J., & Franke, J. E. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6699763 · Cited by 16
Research on fault analysis and diagnosis of PMSM in HEV
Yu, H., Liu, Z., & Cui, S. (2011) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2011.6073632 · Cited by 9
Research works printed but not linked: 1
- miller, 1989, Permanent Magnet and Reluctance Motor Drives
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The PM demagnetization can be uniform over all poles or partial over certain region or poles [15], [18], [29], [32].”
BackgroundMethodInfluentialChoi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Hang, J., Zhang, J., Xia, M., Ding, S., & Hua, W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2953269 · Cited by 150
Yepes, A. G., López, Ó., González‐Prieto, I., Duran, M. J., & Doval‐Gandoy, J. (2022) · Machines · doi:10.3390/machines10030208 · Cited by 150
In-Wheel Motor Vibration Control for Distributed-Driven Electric Vehicles: A Review
Zhao, Z. X., Taghavifar, H., Du, H., Qin, Y., Dong, M., & Gu, L. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3074970 · Cited by 129
Metadata
- Authors
- Faiz, J., & Mazaheri-Tehrani, E.
- Affiliations
- University of Tehran (IR)
- ORCID
- Faiz, Jawad
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2017-05
- Volume
- 53
- Issue
- 3
- Pages
- 2772-2785
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2519918482
- Cited by
- 207
- References
- 72
- Citations by year
- 2026: 10 · 2025: 30 · 2024: 32 · 2023: 39 · 2022: 31 · 2021: 18 · 2020: 17 · 2019: 19 · 2018: 8 · 2017: 3
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet machines, demagnetization fault, fault diagnosis, non-stationary conditions, stationary conditions, motor performance degradation, reliability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.