Protection of Microgrids During Utility Voltage Sags
Abstract
Microgrids are systems with clusters of microgenerators, which are installed for distributed power generation. When interfaced to the utility grid, microgrids are exposed to common utility power-quality disturbances. In particular, during utility-voltage sags, large line currents can flow along distribution feeders connecting the micro- and utility grids. To limit this flow of large line currents and, hence, protect the microgrids, this paper proposes two current-limiting algorithms, namely, the$RL$feedforward and flux-charge-model feedback algorithms, for controlling a series inverter connected between the micro- and utility grids during utility voltage sags. Both methods function by inserting a large virtual$RL$or$L$impedance in series with the distribution feeder to limit the line-current flow. Detailed descriptions, controller designs, and comparisons of both algorithms are presented. Phasor analyses of both methods are also presented to show how the inserted$RL$or$L$values can be optimally tuned to improve the inverter damping performance and minimize its injected voltages and circulating power under all operation conditions. Lastly, both methods have been tested in simulation and in experiments using an emulated laboratory microgrid system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Basak, P., Chowdhury, S., Halder nee Dey, S., & Chowdhury, S. P. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.05.043 · Cited by 508
Comparison of Three Single-Phase PLL Algorithms for UPS Applications
Santos Filho, R. M., Seixas, P. F., Cortizo, P. C., Torres, L. A. B., & Souza, A. F. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924205 · Cited by 469
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
Wind Turbine Power Coefficient Analysis of a New Maximum Power Point Tracking Technique
Xia, Y., Ahmed, K. H., & Williams, B. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2206332 · Cited by 256
Metadata
- Authors
- Vilathgamuwa, D. M., Loh, P. C., & Li, Y.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2006-10
- Volume
- 53
- Issue
- 5
- Pages
- 1427-1436
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2162739864
- Cited by
- 215
- References
- 0
- FWCI
- 16.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Protection of Microgrids During Utility Voltage Sags. https://app.cochat.ai/papers/10.1109/tie.2006.882006
- The paper
- Vilathgamuwa, D. M., Loh, P. C., & Li, Y. (2006). Protection of Microgrids During Utility Voltage Sags. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2006.882006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.