Static-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Mixed-eccentricity (ME) fault diagnosis has not been so far documented for permanent-magnet (PM) synchronous motors (PMSMs). This paper investigates how the static eccentricity (SE), dynamic eccentricity (DE), and ME in three-phase PMSMs can be detected. A novel index for noninvasive diagnosis of these eccentricities is introduced for a faulty PMSM. The nominated index is the amplitude of sideband components with a particular frequency pattern which is extracted from the spectrum of stator current. Using this index makes it possible to determine the occurrence, as well as the type and percentage, of eccentricity precisely. Meanwhile, the current spectrum of the faulty PMSM during a large span is inspected, and the ability of the proposed index is exhibited to detect eccentricity in faulty PMSMs with different loads. A novel theoretical scrutiny based on a magnetic field analysis is presented to prove the introduced index and generalize the illustrated fault recognition method. To show the merit of this index in the eccentricity detection and estimation of its severity, first, the correlation between the index and the SE and DE degrees is determined. Then, the type of the eccentricity is determined by ak-nearest neighbor classifier. At the next step, a three-layer artificial neural network is employed to estimate the eccentricity degree and its type. After all, a white Gaussian noise is added to the simulated current, and the robustness of the proposed index is analyzed with respect to the noise variance. In this paper, the PMSM under magnetic fault (demagnetization) and electrical faults (short and open circuits) is modeled, and the current spectrum of the faulty PMSM under demagnetization, short circuit, and open circuit faults is analyzed. It is demonstrated that the proposed index, due to eccentricity fault, is not generated in the current spectrum due to magnetic and electrical faults. Indeed, it is exposed that the introduced index is only created due to eccentricity fault and it is not sensitive to other faults. To model the PMSM eccentricities, a time-stepping finite-element method, which takes into account all geometrical and physical characteristics of the machine components, nonuniform permeance of the air gap, and nonuniform characteristics of the PM material, is employed. This model facilitates the access to the demanded signals in order to have accurate processing. A comparison of simulation and experimental results validate the proposed index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Barker, L. (2002) · Technometrics · doi:10.1198/tech.2002.s659 · Cited by 2,477
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568
Quantitative evaluation of induction motor broken bars by means of electrical signature analysis
Bellini, A., Filippetti, F., Franceschini, G., Tassoni, C., & Kliman, G. B. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952499 · Cited by 483
Detecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274
Kim, U., & Lieu, D. K. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.703862 · Cited by 189
Blodt, M., Bonacci, D., Regnier, J., Chabert, M., & Faucher, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911941 · Cited by 181
Khan, M., & Rahman, M. A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004662 · Cited by 163
Strangas, E. G., Aviyente, S., & Zaidi, S. S. H. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007529 · Cited by 148
Low Order PWM Inverter Harmonics Contributions to the Inverter-Fed Induction Machine Fault Diagnosis
Akin, B., Orguner, U., Toliyat, H. A., & Rayner, M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911954 · Cited by 140
Comprehensive Eccentricity Fault Diagnosis in Induction Motors Using Finite Element Method
Faiz, J., Ebrahimi, B. M., Akin, B., & Toliyat, H. A. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2012812 · Cited by 132
Self-citationKim, U., & Lieu, D. K. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.703863 · Cited by 127
Analytical Prediction of the Short-Circuit Current in Fault-Tolerant Permanent-Magnet Machines
Sun, Z., Wang, J., Howe, D., & Jewell, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005019 · Cited by 121
Rosu, M., Saitz, J., & Arkkio, A. (2005) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2005.848319 · Cited by 91
Yoon, T. (2005) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2005.848321 · Cited by 60
Niu, G., Son, J.-D., Widodo, A., Yang, B., Hwang, D.-H., & Kang, D.-S. (2007) · Structural Health Monitoring · doi:10.1177/1475921707081110 · Cited by 49
Kim, T., Hwang, S.-M., Kim, K., Jung, W.-B., & Kim, C.-U. (2001) · IEEE Transactions on Magnetics · doi:10.1109/20.951316 · Cited by 48
Magnetic lumped parameter modeling of rotor eccentricity in brushless permanent-magnet motors
Wang, J.-P., & Lieu, D. K. (1999) · IEEE Transactions on Magnetics · doi:10.1109/20.799071 · Cited by 41
Cited by
Deep Learning-Based Intelligent Fault Diagnosis Methods Toward Rotating Machinery
Tang, S., Yuan, S., & Zhu, Y. (2020) · IEEE Access · doi:10.1109/access.2019.2963092 · Cited by 323
Da, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303
“Mixed eccentricity is the combination of static and dynamic eccentricity defined by [30]”
BackgroundModeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 282
Ebrahimi, B. M., Javan Roshtkhari, M., Faiz, J., & Khatami, S. V. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2263777 · Cited by 271
Self-citationFaults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Metadata
- Authors
- Ebrahimi, B. M., Faiz, J., & Roshtkhari, M. J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-11
- Volume
- 56
- Issue
- 11
- Pages
- 4727-4739
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2127136782
- Cited by
- 386
- References
- 17
- FWCI
- 27.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.