Multiple-Complex Coefficient-Filter-Based Phase-Locked Loop and Synchronization Technique for Three-Phase Grid-Interfaced Converters in Distributed Utility Networks
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Synchronization with the utility networks is crucial for operating three-phase grid-interfaced converters. A challenge of synchronization is how to fast and precisely extract the fundamental positive and negative sequences under the distorted and unbalanced conditions. Many phase-locked loop (PLL) and synchronization techniques have been presented in the past decades. Most of them make a tradeoff between the accuracy and dynamic response under severe distorted and unbalanced conditions. In this paper, a multiple-complex coefficient-filter-based PLL is presented, and its unique feature lies in the accurate and rapid extraction of the positive and negative sequence components from the polluted grid voltage, and the harmonic components can also be estimated precisely, which has the potential use for selective compensation in active filter applications. Another advantage of the proposed method is its flexibility for simplifying its structure in some specified conditions. Results of continuous-domain simulations in MATLAB and discrete-domain experiments based on a 32-b fixed-point TMS320F2812 DSP are in good agreement, which confirm the effectiveness of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
A Review of the State of the Art of Power Electronics for Wind Turbines
Chen, Z., Guerrero, J. M., & Blaabjerg, F. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2017082 · Cited by 1,487
Self-citationDecoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
A new single-phase PLL structure based on second order generalized integrator
Ciobotaru, M., Teodorescu, R., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1711988 · Cited by 1,189
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567077 · Cited by 997
Dual current control scheme for PWM converter under unbalanced input voltage conditions
Song, H.-S., & Nam, K. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793344 · Cited by 930
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (2002) · Proceedings of Applied Power Electronics Conference. APEC '96 · doi:10.1109/apec.1996.500517 · Cited by 903
Yuan, X., Merk, W., Stemmler, H., & Allmeling, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993175 · Cited by 896
Rodríguez, P., Teodorescu, R., Candela, I., Timbus, A. V., Liserre, M., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1712059 · Cited by 842
Cited by
Self-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit
Zhong, Q.-C., Nguyen, P.-L., Ma, Z., & Sheng, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2258684 · Cited by 1,026
Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines
Golestan, S., Ramezani, M., Guerrero, J. M., Freijedo, F. D., & Monfared, M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2273461 · Cited by 564
Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters
Wu, H., & Wang, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2937942 · Cited by 454
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2892142 · Cited by 415
Dynamics Assessment of Advanced Single-Phase PLL Structures
Golestan, S., Monfared, M., Freijedo, F. D., & Guerrero, J. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2193863 · Cited by 371
Golestan, S., Ramezani, M., Guerrero, J. M., & Monfared, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2315872 · Cited by 240
“Using the complex coefficient filters (CCFs) as the PLL’s prefiltering stage can be found in [5] and [6].”
MethodGuo, X., Liu, W., & Lu, Z. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2669018 · Cited by 201
“2, the multiple complex-coefficient-filter (MCCF)phase-locked loop (PLL) is used for estimating the positive and negative sequences of grid voltage [26].”
MethodSelf-citationXie, M., Wen, H., Zhu, C., & Yang, Y. (2017) · IEEE Access · doi:10.1109/access.2017.2719721 · Cited by 171
“It shows that the gain is unity at the positive offset frequency components, while it can attenuate the negative offset frequency components and other harmonic components [27].”
BackgroundGuo, C., Yang, J., & Zhao, C. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2831193 · Cited by 53
“MCCF gains surely affect the dynamics of the MMC system and the ωi i and ωi u values are required to be properly selected according to the recommendation from [17] and the small-signal”
BackgroundMethodInfluential
Metadata
- Authors
- Guo, X., Wu, W., & Chen, Z.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-04
- Volume
- 58
- Issue
- 4
- Pages
- 1194-1204
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2130476408
- Cited by
- 475
- References
- 26
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.