Feature Extraction of Demagnetization Faults in Permanent-Magnet Synchronous Motors Based on Box-Counting Fractal Dimension
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper presents a methodology for feature extraction of a new fault indicator focused on detecting demagnetization faults in a surface-mounted permanent-magnet synchronous motors operating under nonstationary conditions. Preprocessing of transient-current signals is performed by applying Choi-Williams distribution to highlight the salient features of this demagnetization fault. In this paper, fractal dimension calculation based on the computation of the box-counting method is performed to extract the optimal features for diagnosis purposes. It must be noted that the applied feature-extraction process is autotuned, so it does not depend on the severity of the fault and is applicable to a wide range of operating conditions of the motor. The performance of the proposed system is validated experimentally. According to the obtained results, the proposed methodology is reliable and feasible for diagnosing demagnetization faults in industrial applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140 · cited 2×
“Additionally, the Fourier transform may even mask components that appear in a given time instant but are of very short duration [7].”
BackgroundRajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines
Rosero, J. A., Cusido, J., Garcia, A., Ortega, J. A., & Romeral, L. (2006) · IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics · doi:10.1109/iecon.2006.347598 · Cited by 67 · cited 1×
“currents produced by inverter or stator-winding faults or even by temperature [13], [14].”
BackgroundSelf-citationStator short circuits detection in PMSM by means of Hilbert-Huang transform and energy calculation
Urresty, J., Riba, J., Romeral, L., Rosero, J., & Serna, J. (2009) · 2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2009.5292789 · Cited by 29
Self-citation
Research works printed but not linked: 36
- auger, 1995, TimeFrequency Toolbox for use With MATLAB
- casadei, 2009, Magnets faults characterization for Permanent Magnet Synchronous Motors, Proc IEEE Int SDEMPED, 1
- 10.1007/s11442-009-0340-5 · doi:10.1007/s11442-009-0340-5
- 10.1016/j.patcog.2008.07.006 · DOI
- 10.1016/j.patcog.2009.03.001 · DOI
- 10.1109/TBME.2006.878067 · DOI
- 10.1109/TDEI.2004.1266323 · doi:10.1109/tdei.2004.1266323
- 10.1109/TDEI.2009.4784566 · doi:10.1109/tdei.2009.4784566
- 10.1109/14.108154 · doi:10.1109/14.108154
- 10.1002/ldr.877 · DOI
- 10.1109/TMAG.2006.871637 · DOI · Paper page
- 10.1017/S0022112004009802 · doi:10.1017/s0022112004009802
- 10.1109/TIE.2008.918402 · doi:10.1109/tie.2008.918402
- xiao, 2008, Magnet demagnetization observation for permanent magnet synchronous motor, Proc IEEE Int Conf Elect Mach Syst, 3216
- ki-chan, 2006, The shape design of permanent magnet for permanent magnet synchronous motor considering partial demagnetization, IEEE Trans Mag, 42, 3485, 10.1109/TMAG.2006.879077 · DOI · Paper page
- 10.1109/ISIE.2008.4677217 · DOI · Paper page
- 10.1109/TMAG.2009.2015942 · DOI · Paper page
- rosero, 2007, Fault detection by means of wavelet transform in a PMSM under demagnetization, Proc 22nd Annu IEEE IECON, 1149
- 10.1109/DEMPED.2009.5292787 · doi:10.1109/demped.2009.5292787
- rajagopalan, 2006, Detection of Rotor and Load Faults in Brushless dc Motors Operating Under Stationary and Nonstationary Conditions
- 10.1109/TIE.2009.2029577 · DOI · Paper page
- 10.1109/TIA.2006.882613 · DOI · Paper page
- 10.1109/TIE.2008.918403 · DOI · Paper page
- 10.1109/TIE.2008.2004662 · DOI · Paper page
- 10.1109/TBME.2006.873543 · DOI · Paper page
- 10.1109/TIE.2009.2025715 · DOI
- 10.1109/TIE.2009.2026770 · DOI · Paper page
- 10.1109/TIE.2009.2016517 · DOI
- 10.1109/07IAS.2007.292 · DOI
- 10.1109/TIE.2008.2011580 · DOI · Paper page
- 10.1109/TIE.2009.2034181 · DOI
- 10.1109/DEMPED.2007.4393131 · DOI
- rajagopalan, 2005, Wigner–Ville distributions for detection of rotor faults in brushless DC (BLDC) motors operating under nonstationary conditions, Proc IEEE Int SDEMPED, 1
- 10.1109/TIE.2008.2007529 · DOI · Paper page
- sajjad, 2007, Comparative study of time–frequency methods for the detection and categorization of intermittent faults in electrical drives, Proc IEEE Int SDEMPED, 39
- 10.1109/TIA.2008.921431 · DOI · Paper page
Cited by
Riera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“Then, these CWD-prepared damage characteristics are extracted using the box counting method.”
MethodInfluentialA review on non-model based diagnosis methodologies for PEM fuel cell stacks and systems
Zheng, Z., Petrone, R., Péra, M. C., Hissel, D., Becherif, M., Pianese, C., Yousfi Steiner, N., & Sorrentino, M. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.04.007 · Cited by 232
“Prieto et al. (2011) [71] presented a diagnosis method based on CWD for detecting permanent-magnet synchronous motors (PMSM).”
MethodFaiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
“By detecting this signature current, asymmetric magnet fault can be detected, and this has been described in [3], [19], [20] and [85].”
BackgroundMethodDemagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview
Faiz, J., & Nejadi-Koti, H. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2480379 · Cited by 119
“[16], [17], Hilbert-Huang transform [18], [19], and Cohen’s class distribution [20] are the transformations used for extract-”
MethodPark, Y., Fernandez, D., Lee, S. B., Hyun, D., Jeong, M., Kommuri, S. K., Cho, C., Diaz Reigosa, D., & Briz, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2886772 · Cited by 116
Moosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.04.062 · Cited by 96
Demagnetization Fault Diagnosis in Surface Mounted Permanent Magnet Synchronous Motors
Ebrahimi, B. M., & Faiz, J. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2217978 · Cited by 95
“The big difference between this index and two investigated indices in [12], [13] is processing voltages instead of stator currents.”
BackgroundMethodUrresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2247046 · Cited by 73
“Short-circuits due to inverter or stator-windings faults may also generate fault currents high enough to move the operation point of the rotor magnets into the irreversible demagnetization region [8].”
BackgroundSelf-citation
Metadata
- Authors
- Prieto, M. D., Espinosa, A. G., Ruiz, J.-R. R., Urresty, J. C., & Ortega, J. A.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-05
- Volume
- 58
- Issue
- 5
- Pages
- 1594-1605
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2163933103
- Cited by
- 95
- References
- 4
- FWCI
- 9.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.