Extended Range ZVS Active-Clamped Current-Fed Full-Bridge Isolated DC/DC Converter for Fuel Cell Applications: Analysis, Design, and Experimental Results
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
This paper presents analysis and design of zero-voltage switching (ZVS) active-clamped current-fed full-bridge isolated dc/dc converter for fuel cell applications. The designed converter maintains ZVS of all switches from full load down to very light load condition over wide input voltage variation. Detailed operation, analysis, design, simulation, and experimental results for the proposed design are presented. The additional auxiliary active clamping circuit absorbs the turn-off voltage spike limiting the peak voltage across the devices allowing the selection and use of low-voltage devices with low on-state resistance. In addition, it also assists in achieving ZVS of semiconductor devices. The converter utilizes the energy stored in the transformer leakage inductance aided by its magnetizing inductance to maintain ZVS. ZVS range depends upon the design, in particular the ratio of leakage and magnetizing inductances of the transformer. Rectifier diodes operate with zero-current switching. An experimental converter prototype rated at 500 W has been designed, built, and tested in the laboratory to verify the analysis, design, and performance for wide variations in input voltage and load.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transformer-Coupled Multiport ZVS Bidirectional DC–DC Converter With Wide Input Range
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915129 · Cited by 478 · cited 1×
“in [29], but secondary side switches lose ZVS at light load and higher input voltage, the ZVS range is calculated in [14].”
BackgroundHigh-Efficiency Isolated Boost DC–DC Converter for High-Power Low-Voltage Fuel-Cell Applications
Nymand, M., & Andersen, M. A. E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036024 · Cited by 312
Harfman Todorovic, M., Palma, L., & Enjeti, P. N. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911200 · Cited by 263
Kwon, J.-M., & Kwon, B.-H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2006268 · Cited by 251 · cited 1×
“Converter presented in [25] is hard switched, and two devices are connected in parallel to improve the efficiency and switching frequency is 50 kHz.”
BackgroundLow Cost Fuel Cell Converter System for Residential Power Generation
Wang, J., Peng, F. Z., Anderson, J., Joseph, A., & Buffenbarger, R. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833455 · Cited by 240 · cited 1×
“A topology similar to [4] is presented”
Jin, K., & Ruan, X. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.882020 · Cited by 217
Full-bridge isolated current fed converter with active clamp
Yakushev, V., Meleshin, V., & Fraidlin, S. (1999) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1999.749736 · Cited by 157 · cited 1×
“It should be noted that the magnetizing inductance makes the transformer leakage inductance current continuous and also increases the number of state variables [21].”
BackgroundHigh-Efficiency Power Conversion for Low Power Fuel Cell Generation System
Wai, R., & Duan, R.-Y. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.850936 · Cited by 157
A Nonisolated Bidirectional ZVS-PWM Active Clamped DC–DC Converter
Das, P., Laan, B., Mousavi, S. A., & Moschopoulos, G. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2006897 · Cited by 132 · cited 1×
“been proposed [30] for ZVS up to 40% load but operation with wide input voltage variation is not reported.”
BackgroundA Universal Grid-Connected Fuel-Cell Inverter for Residential Application
Mazumder, S. K., Burra, R. K., Huang, R., Tahir, M., & Acharya, K. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2038943 · Cited by 127
Current-Fed Dual-Bridge DC–DC Converter
Song, W., & Lehman, B. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889927 · Cited by 73 · cited 1×
“A solution to achieve ZVS over 1:2 source voltage variation using several extra components is given [31] without discussing ZVS for variation in load.”
MethodNovel Half-Bridge Inductive DC–DC Isolated Converters for Fuel Cell Applications
Lembeye, Y., Bang, V. D., Lefevre, G., & Ferrieux, J. P. (2009) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2008.2006553 · Cited by 71
Mohr, M., & Fuchs, F. W. (2007) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417676 · Cited by 28 · cited 1×
“Hard-switching topology for low switching frequency operation is discussed in [23], [24].”
Background
Cited by
Xuewei, P., & Rathore, A. K. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2271599 · Cited by 246
“In [18]–[23], the leakage inductance and the parasitic capacitance of the HF transformer were utilized to achieve zero-current switching (ZCS) soft switch-”
MethodSelf-citationPan, X., Li, H., Liu, Y., Zhao, T., Ju, C., & Rathore, A. K. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2931739 · Cited by 215
“Active clamp has been implemented in many fundamental topologies [16]–[19], such as full-bridge current-fed topology as shown in Fig.”
BackgroundSelf-citationComparative analysis of bidirectional three-level DC–DC converter for automotive applications
Dusmez, S., Hasanzadeh, A., & Khaligh, A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2336605 · Cited by 204
Metadata
- Authors
- U R, P., & Rathore, A. K.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-07
- Volume
- 60
- Issue
- 7
- Pages
- 2661-2672
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2112806004
- Cited by
- 169
- References
- 13
- FWCI
- 8.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.