An Overview and Comprehensive Comparative Evaluation of Current-Fed-Isolated-Bidirectional DC/DC Converter
The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
Renewable energy generations have been attracting sustained attentions in academic and industry. Current-fed-isolated-bidirectional dc/dc converters (CF-IBDCs) are widely adopted in low-voltage high-current applications such as solar photovoltaic fuel cell with energy storage. This paper gives an overview and a comprehensive comparative evaluation of CF-IBDCs. The active clamped, dual half-bridge, L-L type dual active bridge, resonant-type, naturally clamped, and other type topologies of CF-IBDCs are investigated, analyzed, and compared regarding their circuit topological structures, operation characteristics, modulation methods, and soft-switching technologies. In addition, component cost models and loss models of converters are deduced and presented. On this basis, quantitative and comprehensive performance comparison of seven typical CF-IBDC topologies selected from each type is conducted in terms of costs, losses, weight, volume, and power density for the given system specifications and design constraints. Finally, the application range of different CF-IBDCs and future trend are presented to encourage further development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018 · cited 1×
“of renewable energy generation into the power grid and is widely used and rapidly expanded [1]–[3].”
BackgroundBiela, J., Schweizer, M., Waffler, S., & Kolar, J. W. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2072896 · Cited by 892
A new ZVS bidirectional DC-DC converter for fuel cell and battery application
Peng, F. Z., Li, H., Su, G.-J., & Lawler, J. S. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820550 · Cited by 782 · cited 6×
“Compared with the topologies and control scheme in [34]–[36], the proposed control strategy performs better under”
BackgroundMethodInfluentialSelf-citationCalculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. A. A. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.936396 · Cited by 704
Calculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.806023 · Cited by 409
Zhu, L. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.869730 · Cited by 381 · cited 2×
“This is referred as active commutation technique or natural clamping technique [71], [72].”
BackgroundMethodA bidirectional DC–DC converter for fuel cell electric vehicle driving system
Chiu, H.-J., & Lin, L.-W. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.876863 · Cited by 327 · cited 1×
“37 shows an asymmetrical half-bridge bidirectional dc/dc converter [90].”
BackgroundA ZVS Bidirectional DC–DC Converter With Phase-Shift Plus PWM Control Scheme
Xiao, H., & Xie, S. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915188 · Cited by 299
Optimized Operation of Current-Fed Dual Active Bridge DC–DC Converter for PV Applications
Shi, Y., Li, R., Xue, Y., & Li, H. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2432093 · Cited by 298 · cited 1×
“The clamping capacitor Ca can also be connected to the ground of primary side [21].”
BackgroundSelf-citationA natural ZVS medium-power bidirectional DC-DC converter with minimum number of devices
Li, H., Peng, F. Z., & Lawler, J. S. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.808965 · Cited by 296 · cited 4×
“Based on the conventional dual half-bridge CF-IBDC [34], [35], Sun et al.”
BackgroundMethodInfluential
Metadata
- Authors
- Pan, X., Li, H., Liu, Y., Zhao, T., Ju, C., & Rathore, A. K.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2020-03
- Volume
- 35
- Issue
- 3
- Pages
- 2737-2763
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2966150139
- Cited by
- 215
- References
- 76
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Overview and Comprehensive Comparative Evaluation of Current-Fed-Isolated-Bidirectional DC/DC Converter. https://app.cochat.ai/papers/10.1109/tpel.2019.2931739
- The paper
- Pan, X., Li, H., Liu, Y., Zhao, T., Ju, C., & Rathore, A. K. (2020). An Overview and Comprehensive Comparative Evaluation of Current-Fed-Isolated-Bidirectional DC/DC Converter. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2019.2931739
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.