D-Q Current Signature-Based Faulted Phase Localization for SM-PMAC Machine Drives
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Fault diagnostic algorithms in motor drives prevent damage to the motor, drive, and overall system by providing an additional level of safety. A single phase open (SPO) fault in a field-oriented controlled drive is one of the perilous faults that require immediate detection due to resulting oscillatory electromagnetic torque. SPO fault results in a significantly high electromagnetic torque ripple. The rapid mechanical vibration caused by the torque ripple exposes the system to failure modes. The single open phase fault detection algorithm proposed in this paper enables the rapid detection of the fault, with minimal system resources, compared to existing methods. Proof of accurate fault detection capability for a wide speed range is presented through simulation and experimental results. The proposed method is also capable of localizing the faulted phase via a novel time domain rotor reference frame current signature analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Torque-producing q-axis current component [38], [182] and a ratio between d-and qaxis components [185] have been applied to design a diagnostic method so far;”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [185]
In the citing paper
“When a predefined threshold is exceeded the decision about the fault is made.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [185]
In the citing paper
“When the PMSM is healthy the ratio is close to infinity (d-axis component close to zero), while the FI is close to zero.When the machine is faulty, the FI is no longer zero.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [185]
In the citing paper
“A simple and fast diagnostic method for single open phase fault detection based on control structure signals has been first proposed in [184] and further developed in [185].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [185]
In the citing paper
“The diagnostic method shown in [185] can easily determine the faulty phase, based on the difference between estimated and real electrical angles of rotor shaft position.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [185]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Bibliographical review on reconfigurable fault-tolerant control systems
Zhang, Y., & Jiang, J. (2008) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2008.03.008 · Cited by 2,652
Analysis of Electric Machinery and Drive Systems
Krause, P. C., Wasynczuk, O., & Sudhoff, S. D. (2002) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544167 · Cited by 2,314
A survey of design methods for failure detection in dynamic systems
Willsky, A. S. (1976) · Automatica · doi:10.1016/0005-1098(76)90041-8 · Cited by 2,153 · cited 1×
“Fault diagnostic schemes are classified into several categories: failure sensitive filters, voting systems, multiple hypothesis filter detectors, jump process formulation, and model-based fault diagnostics (also known as innovation-based detection systems) [11].”
BackgroundVector Control and Dynamics of AC Drives
Novotny, D. W., & Lipo, T. A. (1996) · doi:10.1093/oso/9780198564393.001.0001 · Cited by 1,841
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Electric Motor Drive Selection Issues for HEV Propulsion Systems: A Comparative Study
Zeraoulia, M., Benbouzid, M. E. H., & Diallo, D. (2006) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2006.878719 · Cited by 691
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
Research works printed but not linked: 1
- liu, 2006, Robust Fault Detection and Diagnosis for Permanent Magnet Synchronous Motors
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“A simple and fast diagnostic method for single open phase fault detection based on control structure signals has been first proposed in [184] and further developed in [185].”
MethodChoi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
“The single open-phase detection algorithm proposed in [182] compares the phase shift in the fault detection signal with respect to the actual electrical angle to detect single phase fault in PM motors.”
MethodCurrent-Based Open-Circuit Fault Diagnosis for PMSM Drives With Model Predictive Control
Huang, W., Du, J., Hua, W., Lu, W., Bi, K., Zhu, Y., & Fan, Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3061448 · Cited by 140
“dq-current signature-based approach was proposed for the openphase fault (OPF) detection of surface-mount PMSM drives [21].”
BackgroundDetection and Discrimination of Open Phase Fault in Permanent Magnet Synchronous Motor Drive System
Hang, J., Zhang, J., & Cheng, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2479399 · Cited by 115
“Therefore, the currents-based open-phase fault detection methods introduced in [6]–[9] are invalid to discriminate the fault type since the waveforms of the stator current are nearly same under different fault types, such as ISWF and TSF.”
MethodInfluentialHang, J., Wu, H., Zhang, J., Ding, S., Huang, Y., & Hua, W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3011450 · Cited by 118
“Once the OPF occurs, the second-order harmonics are generated in dq-axis currents and are used for the OPF diagnosis [22].”
Method
Metadata
- Authors
- Kuruppu, S. S., & Kulatunga, N. A.
- Affiliations
- Purdue University West Lafayette (US)
- ORCID
- Kuruppu, Sandun S.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-01
- Volume
- 62
- Issue
- 1
- Pages
- 113-121
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2060623171
- Cited by
- 51
- References
- 37
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 3 · 2023: 7 · 2022: 4 · 2021: 5 · 2020: 5 · 2019: 5 · 2018: 4 · 2017: 8 · 2016: 1 · 2015: 3
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Funders
- Purdue University Research Foundation
- International Rectifier Corporation
- Purdue University College of Technology
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- fault detection, permanent magnet synchronous motor, field-oriented control, current signature analysis, rotor reference frame, torque ripple, motor drives, sensorless drive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.