CoChat

Effective Test Bed of 380-V DC Distribution System Using Isolated Power Converters

Ryu, Myung-Hyo, Kim, Ho-Sung, Baek, Ju-Won, Kim, Heung-Geun, Jung, Jee-Hoon · 2015 · IEEE Transactions on Industrial Electronics
Cited by 158

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

This paper proposes an effective test bed for a 380-V dc distribution system using isolated power converters. The proposed test-bed system is composed of a grid-interactive ac-dc converter for regulating the dc-bus voltage, a bidirectional converter for the battery power interface, a renewable energy simulator, dc home appliances modified from conventional ac components, a dc distribution panel board, and its monitoring system. This paper discusses three isolated power converters, i.e., a bidirectional ac-dc converter, a bidirectional dc-dc converter, and a unidirectional dc-dc converter for the effective power interface of a dc bus. These isolated power converters are designed using a dual-active-bridge converter and the resonant topologies of CLLC and LLC. The proposed test-bed system was implemented using a 5-kW bidirectional ac-dc prototype converter, a 3-kW bidirectional dc-dc prototype converter, and a 3-kW unidirectional dc-dc prototype converter. Finally, the performance of the test-bed system has been verified using practical experiments of load variations and bidirectional power flow, employing the prototype converters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2015.2399273

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 158

Metadata

Authors
Ryu, M.-H., Kim, H.-S., Baek, J.-W., Kim, H.-G., & Jung, J.-H.
Venue
IEEE Transactions on Industrial Electronics
Published
2015-07
Volume
62
Issue
7
Pages
4525-4536
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W1970900775
Cited by
158
References
3
FWCI
7.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effective Test Bed of 380-V DC Distribution System Using Isolated Power Converters. https://app.cochat.ai/papers/10.1109/tie.2015.2399273
The paper
Ryu, M.-H., Kim, H.-S., Baek, J.-W., Kim, H.-G., & Jung, J.-H. (2015). Effective Test Bed of 380-V DC Distribution System Using Isolated Power Converters. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2015.2399273

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.