A Novel Diagnostic Technique for Open-Circuited Faults of Inverters Based on Output Line-to-Line Voltage Model
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
An output line-to-line voltage model-based fault diagnostic technique is presented in this paper. From the theoretical analysis of the output voltage under normal and faulty conditions, a preprocessing method is developed to extract fault features from diagnosis eigenvalue. A voltage envelope line is generated by the proposed voltage envelope function. By comparing the preprocessed diagnosis eigenvalue and the voltage envelope, single-switch open-circuit faults can be located precisely. Because the proposed method does not rely on the accurate amplitude of the output line-to-line voltage, the influence of the load changing is minimized and simple hardware is adopted, which has advantages of low cost, high reliability, and short diagnosis time. Moreover, as long as the inverter output voltages have the feature of periodic nonpositive and nonnegative, this method is valid no matter what control strategy is adopted by the inverter and no control signal is required for the diagnosis process. The prototype system is tested to validate the adaptability of the proposed method under different conditions, such as the diverse loads, various control strategies, and fault-occurrence time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Survey on Reliability of Power Electronic Systems
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192503 · Cited by 861
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 2×
“The fault diagnosis methods of this category have been reported in [7]–[23].”
BackgroundMethodEstima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377 · cited 1×
“Because the switch short-circuit faults can be easily transferred into switch open-circuit faults by means of fast fuses [9], [25], [26], this paper is mainly focusing on switch open-circuit”
BackgroundJi, B., Pickert, V., Cao, W., & Zahawi, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2251358 · Cited by 329 · cited 2×
“Insulated gate bipolar transistor (IGBT) failures are analyzed in [5] and [6].”
BackgroundMethodOpen-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Sleszynski, W., Nieznanski, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300 · cited 1×
“An improved normalized dc-components-based diagnosis method is proposed in [18].”
MethodFault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299 · cited 1×
“The fault diagnosis methods of this category have been reported in [7]–[23].”
MethodJung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271 · cited 1×
“switch fault in [19].”
Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System
Choi, U.-M., Jeong, H.-G., Lee, K.-B., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2178435 · Cited by 241
Jlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2342506 · Cited by 212 · cited 2×
“In [10], an algorithm for multiple open-circuit faults diagnosis in full-scale back-toback converters is presented; the phase current is processed to”
BackgroundMethod
Cited by
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“shows that they may be classified as current signatures [12]– [20], [22]–[25], [30], [33]–[36] and voltage signatures based methods [26]–[29], [31], [32].”
BackgroundMethodDiagnosis of Open-Switch and Current Sensor Faults in PMSM Drives Through Stator Current Analysis
Khojet El Khil, S., Jlassi, I., Marques Cardoso, A. J., Estima, J. O., & Mrabet-Bellaaj, N. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2930592 · Cited by 147
“Voltage-based approaches are divided into two groups— extra hardware-based approaches [4], [5] and model-based approaches [6]–[8].”
Liang, Y., Wang, R., & Hu, B. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3003058 · Cited by 54
“Line-to-line voltage-based method is more preferred as the neutral point of load is difficult to measure in most industrial application [23], [24].”
BackgroundMethodNaseri, F., Schaltz, E., Lu, K., & Farjah, E. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2019.1498 · Cited by 37
Metadata
- Authors
- Shu, C., Ya-Ting, C., Tian-Jian, Y., & Xun, W.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2016-07
- Volume
- 63
- Issue
- 7
- Pages
- 4412-4421
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2314749856
- Cited by
- 158
- References
- 19
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Diagnostic Technique for Open-Circuited Faults of Inverters Based on Output Line-to-Line Voltage Model. https://app.cochat.ai/papers/10.1109/tie.2016.2535960
- The paper
- Shu, C., Ya-Ting, C., Tian-Jian, Y., & Xun, W. (2016). A Novel Diagnostic Technique for Open-Circuited Faults of Inverters Based on Output Line-to-Line Voltage Model. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2016.2535960
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.