CoChat

A 98.3% Efficient GaN Isolated Bidirectional DC–DC Converter for DC Microgrid Energy Storage System Applications

Xue, Fei, Yu, Ruiyang, Huang, Alex Q. · 2017 · IEEE Transactions on Industrial Electronics
Cited by 199

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

This paper presents a novel 400 to 12 V isolated bidirectional dc-dc converter based on a phase-shift-controlled-modified dual-active-bridge power stage. The proposed converter consists of a half-bridge and center tap with active clamp circuit, which has promising performance for low-voltage high-current applications. 650 V gallium-nitride high electron mobility transistors are used on the high voltage side to avoid issues encountered using Si superjunction MOSFETs in phase-shift-controlled-bidirectional power conversions. The operation principle and power transfer characteristic are obtained based on a time-domain analysis of the inductor current. Design methodology and criteria and converter's efficiency analysis are discussed. Both the analysis and experiments verify that the proposed converter is capable of achieving low power loss and high power density in soft-switching and hard-switching modes. Experimental results are presented for a 1-kW, 400 V-to-12 V dc-dc prototype converter operating at 100 kHz switching frequency. A power density of 30 W/in3and a peak efficiency of 98.3% in a wide input/output voltage range are achieved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2017.2686307

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Xue, F., Yu, R., & Huang, A. Q.
Venue
IEEE Transactions on Industrial Electronics
Published
2017-11
Volume
64
Issue
11
Pages
9094-9103
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W2600934144
Cited by
199
References
9
FWCI
10.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.