The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Design-Oriented Transient Stability Analysis of Grid-Connected Converters With Power Synchronization Control
Open accessAbstract
The power synchronization control (PSC) has been increasingly used with voltage-source converters (VSCs) connected to the weak ac grid. This paper presents an in-depth analysis on the transient stability of the PSC-VSC by means of the phase portrait. It is revealed that the PSC-VSC will maintain synchronization with the grid as long as there are equilibrium points after the transient disturbance. In contrast, during grid faults without any equilibrium points, the critical-clearing angle (CCA) for the PSC-VSC is identified, which is found equal to the power angle of the unstable equilibrium point of the postfault operation. This fixed CCA facilitates the design of power system protection. Moreover, it is also found that the PSC-VSC can still resynchronize with the grid after around one cycle of oscillation, even if the fault-clearing angle is beyond the CCA. This feature reduces the risk of system collapse caused by the delayed fault clearance. These findings are corroborated by simulations and experimental tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Power-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117
A new mathematical model and control of a three-phase AC-DC voltage source converter
Blasko, V., & Kaura, V. (1997) · IEEE Transactions on Power Electronics · doi:10.1109/63.554176 · Cited by 871
Zhou, J. Z., Ding, H., Fan, S., Zhang, Y., & Gole, A. M. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2330518 · Cited by 738
Dong, D., Wen, B., Boroyevich, D., Mattavelli, P., & Xue, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334665 · Cited by 709
Interconnection of Two Very Weak AC Systems by VSC-HVDC Links Using Power-Synchronization Control
Zhang, L., Harnefors, L., & Nee, H.-P. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2047875 · Cited by 452
Mitra, P., Zhang, L., & Harnefors, L. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2273979 · Cited by 157
Analysis of Stability Limitations of a VSC-HVDC Link Using Power-Synchronization Control
Zhang, L., Nee, H., & Harnefors, L. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2085052 · Cited by 146
Cited by
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Self-citationGrid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters
Wu, H., & Wang, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2937942 · Cited by 454
Self-citationLiu, T., Wang, X., Liu, F., Xin, K., & Liu, Y. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3122744 · Cited by 200
Self-citationFault Recovery Analysis of Grid-Forming Inverters With Priority-Based Current Limiters
Fan, B., & Wang, X. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3221209 · Cited by 131
Self-citation
Metadata
- Authors
- Wu, H., & Wang, X.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2019-08
- Volume
- 66
- Issue
- 8
- Pages
- 6473-6482
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2896180559
- Cited by
- 320
- References
- 10
- FWCI
- 12.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design-Oriented Transient Stability Analysis of Grid-Connected Converters With Power Synchronization Control. https://app.cochat.ai/papers/10.1109/tie.2018.2875669
- The paper
- Wu, H., & Wang, X. (2019). Design-Oriented Transient Stability Analysis of Grid-Connected Converters With Power Synchronization Control. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2018.2875669
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.