Finite-Control-Set MPC for Open-Phase Fault-Tolerant Control of PM Synchronous Motor Drives
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
A fault-tolerant permanent magnet synchronous motor drive is proposed in this article. The strategy is based on finite-control-set model-predictive control that is easy to implement and replaces the conventional proportional-integral controllers and pulsewidth modulators. A three-phase four-wire converter topology is used, which connects the neutral of the motor to the middle of the dc link in a capacitive divider. The main contribution of the proposed strategy relies on the fact that no reconfigurations or modifications of the converter topology and the controller strategy are required from normal operation to postfault operation. As a result, the transition from healthy to faulty state is smooth and not noticeable in the torque waveform. In addition, a simple fault detection method is derived by using the predicted variables. Experimental results, obtained from a laboratory prototype, validate the practical feasibility of the proposed strategy and show a pulsation-free torque on fault operation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The main advantage of this solution is that there is no need to converter topology modification after the fault detection and thus the transition from healthy to faulty state is smooth.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [323]
Citations
Cites
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724 · cited 1×
“A simple possibility to allow more than one independent current flow also in faulty operation is by connecting the neutral point of the motor either to the middle of the VSI dc link [4] (a split capacitor bank is required) or to an extra inverter leg [5], as”
BackgroundDesign and Implementation of Model Predictive Control for Electrical Motor Drives
Bolognani, S., Bolognani, S., Peretti, L., & Zigliotto, M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007547 · Cited by 452
Finite-Control-Set Model Predictive Torque Control With a Deadbeat Solution for PMSM Drives
Xie, W., Wang, X., Wang, F., Xu, W., Kennel, R. M., Gerling, D., & Lorenz, R. D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2410767 · Cited by 394 · cited 1×
“A deadbeat solution for an FCS-MPC in terms of the direct torque control was presented in [19].”
MethodExperimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
Preindl, M., & Bolognani, S. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2012.2227265 · Cited by 376 · cited 1×
“In [17], direct torque control of a PMSM using FCS-MPC was”
MethodPreindl, M., & Bolognani, S. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2012.2220353 · Cited by 235 · cited 1×
“introduced for the maximum torque per ampere operation and in [18] for the field weakening operation.”
BackgroundControl Algorithms for a Fault-Tolerant PMSM Drive
Wallmark, O., Harnefors, L., & Carlson, O. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895076 · Cited by 197
Modeling and Control of Three-Phase PMSMs Under Open-Phase Fault
Gaeta, A., Scelba, G., & Consoli, A. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2228614 · Cited by 151
Detection and Discrimination of Open Phase Fault in Permanent Magnet Synchronous Motor Drive System
Hang, J., Zhang, J., & Cheng, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2479399 · Cited by 115 · cited 1×
“A common fault arising directly in the motor, as well as in the associated voltage-source inverter (VSI), is the open-phase fault [1].”
BackgroundCost-Effective Three-Phase PMSM Drive Tolerant to Open-Phase Fault
Kontarcek, A., Bajec, P., Nemec, M., Ambrozic, V., & Nedeljkovic, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2437357 · Cited by 106 · cited 1×
“In [3], as a remedial strategy for the postfault operation to reduce the torque fluctuation, conventional field-oriented control”
Background
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In [323] a FTC strategy based on a finite-controlset MPC was proposed for a three-phase four-wire converter topology of the PMSM drive which connects the neutral point of the motor to the middle of the DC-link capacitor.”
MethodData Mining Applications to Fault Diagnosis in Power Electronic Systems: A Systematic Review
Moradzadeh, A., Mohammadi‐Ivatloo, B., Pourhossein, K., & Anvari‐Moghaddam, A. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3131293 · Cited by 103
Feng, G., Lai, C., Li, W., Han, Y. Q., & Kar, N. C. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3019391 · Cited by 64
Model-Based Fault Diagnosis Algorithms for Robotic Systems
Hasan, A., Tahavori, M., & Midtiby, H. S. (2023) · IEEE Access · doi:10.1109/access.2022.3233672 · Cited by 46
“A possible algorithm for the fault-tolerant control is by using model predictive control (MPC) [14].”
MethodWang, X., Ren, S., Xiao, D., Meng, X., Fang, G., & Wang, Z. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3306457 · Cited by 47
“Digital Object Identifier 10.1109/TTE.2023.3306457 attracted significant attention in many fields, such as aerospace, electric vehicle, rail traction, and ship propulsion [1], [2], [3], [4], [5].”
BackgroundInfluentialLi, W., Feng, G., Li, Z., Toulabi, M. S., & Kar, N. C. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3129283 · Cited by 42
Naseri, K., Vu, M. T., Mobayen, S., Najafi, A., & Fekih, A. (2022) · Mathematics · doi:10.3390/math10132159 · Cited by 38
Phase Loss Detection Using Current Signals: A Review
Dianov, A., & Anuchin, A. (2021) · IEEE Access · doi:10.1109/access.2021.3105483 · Cited by 39
Zhang, P., Chen, R., Xu, X., Yang, L., & Mengyu, R. (2023) · Measurement · doi:10.1016/j.measurement.2023.113711 · Cited by 35
Liu, C., & Shang, J. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3087015 · Cited by 29
Common Predictive Model for PMSM Drives With Interturn Fault Considering Torque Ripple Suppression
Li, W., Hang, J., Ding, S., & Wang, Q. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3232820 · Cited by 32
Abbasi, H., Ghanbari, M., Ebrahimi, R., & Jannati, M. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3026278 · Cited by 26
“In [23], an MPC method with tolerance for OPF was presented for three-phase PMSM drives.”
MethodHu, K., Meng, X., Liu, Z., Xu, J., Lin, G., & Tong, L. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3161988 · Cited by 22
Hu, L., Lei, W., Li, R., & Gao, Y. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3226765 · Cited by 23
Active Broken Rotor Bar Diagnosis in Induction Motor Drives
de la Barrera, P. M., Otero, M., Schallschmidt, T., Bossio, G. R., & Leidhold, R. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3007108 · Cited by 21
Self-citationForstner, G., Kugi, A., & Kemmetmüller, W. (2021) · Control Engineering Practice · doi:10.1016/j.conengprac.2021.104846 · Cited by 22
Influence of Inverter Open Circuit Fault on Multiple Physical Quantities in the PMSM
Tang, H., Li, W., & Wu, Z. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3204414 · Cited by 20
“circular rotating magnetic field [17], [18].”
Chen, Y., Liu, C., Wen, H., & Dong, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3267116 · Cited by 19
Wang, W., Lu, Z., Hua, W., Wang, Z., & Cheng, M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2995241 · Cited by 19
Unified Decoupling Vector Control of Five-Phase Permanent-Magnet Motor With Double-Phase Faults
Chen, C., Zhou, H., Wang, G., & Liu, G. (2020) · IEEE Access · doi:10.1109/access.2020.3017541 · Cited by 16
Li, W., Tang, H., Luo, S., Yan, X., & Wu, Z. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12065 · Cited by 17
Optimized OP-FTC for SPMSM Considering Copper Loss Minimization
Ding, S., Ma, K., Fan, J., Hang, J., & Tan, H. (2022) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2022.3162647 · Cited by 14
Zhang, X., Gauthier, J.-Y., & Lin-Shi, X. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3094478 · Cited by 18
Online Current Optimization Based Fault-Tolerant Control of Standard PMSM Drives
Zhang, Y., Chen, X., Wang, X., Zhang, T., Wang, Z., & Mao, Y. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3398673 · Cited by 14
“In [9] and [10], a split capacitor bank and bidirectional thyristor are used to connect the neutral point of PMSM drive and the midpoint of the DC link to improve the FT capability for OPF.”
MethodChallenges and Advancements in Protection of DC Microgrid System-A Comprehensive Review
Prince, S. K., Panda, K. P., Naayagi, R. T., Padmanaban, S., Khan, B., Affijulla, S., & Panda, G. (2022) · Energy Sources Part A Recovery Utilization and Environmental Effects · doi:10.1080/15567036.2022.2151667 · Cited by 15
Mishra, R., & Saha, T. K. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2992970 · Cited by 12
“(PMSM) [25].”
Hu, Y., Sun, J., Shi, H., Peng, W. J., Zhang, D., & Zhang, K. (2021) · ISA Transactions · doi:10.1016/j.isatra.2021.12.030 · Cited by 12
Zhu, X., Zhao, M., Yang, G., Zhao, C., Wang, H., Mao, J., & Lee, C. H. T. (2024) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2024.3353818 · Cited by 11
“The voltage equation in the natural reference frame can be derived as [28] where u jk , i jk , and e jk represent voltage, current and back electromotive force (EMF) of j -phase in module k .”
BackgroundFeng, L., Wang, Z., Feng, J., & Song, W. (2023) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2023.00033 · Cited by 11
A Hybrid Predictive Control for a Current Source Converter in an Aircraft DC Microgrid
Yang, H., Tu, R., Wang, K., Lei, J., Wang, W., Feng, S. L., & Wei, C. (2019) · Energies · doi:10.3390/en12214025 · Cited by 11
Suti, A., & Rito, G. D. (2024) · Actuators · doi:10.3390/act13010025 · Cited by 12
“Kiselev et al. [24] propose finite-control-set model predictive control to identify and compensate for the open-switch fault; the predicted variables are used as fault symptoms and, in the case of a fault, the system is accommodated for with prediction updates thanks to a four-leg converter.”
MethodWang, S., Zhang, Y., Wu, D., Zhao, J., & Hu, Y. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12151 · Cited by 10
Fault-Tolerant Control of Automated Guided Vehicle Under Centroid Variation
Zhang, Q., Liu, W., & Liu, P. (2022) · IEEE Access · doi:10.1109/access.2022.3187031 · Cited by 10
Passive fault‐tolerant control for discrete parameter system
Du, D., & Li, Z. (2023) · IET Power Electronics · doi:10.1049/pel2.12515 · Cited by 10
Jiang, Y., Peng, Z., Chengcheng, M., Liu, L., Wang, D., & Li, T. (2022) · Ocean Engineering · doi:10.1016/j.oceaneng.2022.112474 · Cited by 10
Aboelhassan, A., Sayed, W. E., Hebala, A., Galea, M., & Bozhko, S. V. (2021) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea51954.2021.9516257 · Cited by 9
Li, H., Li, W. J., Sun, J., Xu, J., Ai, S., Nie, Z., & Song, L. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3363771 · Cited by 8
“M ODEL-BASED predictive DTC (PDTC) methods were proposed for permanent magnet synchronous machine (PMSM) drives [1], [2], [3] and attracted a lot of attention from both academic and industrial fields.”
Finite Control Set MPC for Open-Phase Fault Tolerant Control of Synchronous Reluctance Motor
Kiselev, A., Catuogno, G. R., Kuznietsov, A., & Leidhold, R. (2020) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit45562.2020.9067220 · Cited by 9
Self-citationFault-Tolerant Control of Common Electrical Faults and Sensor Faults in Sensorless PMSM Drives
Zhang, Y., Wang, X., Kong, L., Lu, L., Wang, Z., & Mao, Y. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3574040 · Cited by 9
“For OPF, the FT control schemes can be fulfilled by adding auxiliary circuits [8], [9], [10], using open-winding configuration [11], [12], [13], and increasing phase number [14], [15].”
Zhang, S., Li, Z., & Wang, H.-N. (2024) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2024.3441656 · Cited by 7
“Some common approaches for solving the cost functions are explicit MPC [12], generalized predictive control (GPC) [13], [14], and finite control set model predictive control (FCSMPC) [15], [16], [17], [18].”
Yang, W., Shi, Z., & Zhong, Y. (2022) · International Journal of Robust and Nonlinear Control · doi:10.1002/rnc.5976 · Cited by 7
Li, T., Yao, M., & Sun, X. (2023) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-023-01693-8 · Cited by 7
“In [36], an open-phase fault-tolerant model predictive torque control is proposed, which achieves a smooth transition from the normal state to the fault state without requiring additional reconfiguration of the converter topology and control strategy.”
Saffar, E., Ghanbari, M., & Ebrahimi, R. (2024) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.3977 · Cited by 6
Current disturbance compensation of continuous model predictive control scheme for PMSMs
Luo, P., Zhang, S., Shen, A., Luo, X., & Tang, Q. (2024) · ISA Transactions · doi:10.1016/j.isatra.2024.10.007 · Cited by 5
Dawood, A., Hasaneen, B. M., & Abdel-Aziz, A. M. (2024) · Neural Computing and Applications · doi:10.1007/s00521-023-09387-y · Cited by 5
Wang, Z., Ji, Z., Wang, Z., Wang, H., & Bai, Z. (2025) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2025.111785 · Cited by 5
Zhou, G., Fang, Z., Li, D., Jin, Y., & Wang, Y. (2025) · ISA Transactions · doi:10.1016/j.isatra.2025.07.025 · Cited by 4
Bidirectional Charging Strategy of Electric Vehicle based on Predictive Control Method
Yan, X., Guan, B., & Du, X. (2021) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon53785.2021.9697595 · Cited by 4
“The concept of FCS-MPC is easy to understand and can integrate multiple control objectives into a single cost function and can deal with nonlinear problems with simple and feasible approach [14].”
Backgroundde Oliveira, L. M., Melo, V. F. M. B., da Paz, G. F., Rocha, F. V., & Fabrício, E. L. L. (2024) · Eletrônica de Potência · doi:10.18618/rep.2024.1.0011 · Cited by 4
Wang, H., Zhang, G., & Liu, X. (2024) · Applied Sciences · doi:10.3390/app14188126 · Cited by 4
High-Precision Third Harmonic Fault-Tolerant Control for F-PMSM Based on Adaptive Control Set
Chen, X., Ling, Z., Li, T., Liu, H., Zhou, F., & Ouyang, X. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3562903 · Cited by 4
“Under OCF conditions, the voltage vector (VV) distribution inthecontrolsetoftheFCS-MPCCmethodissparseanduneven, leadingtodegradedcontrolperformance,suchaslargetorque andspeedripples[7],[8].”
Caseiro, L. M. A., & Mendes, A. M. S. (2021) · Energies · doi:10.3390/en14082210 · Cited by 5
Shi, Z., Sun, X., Liu, Y., & Zhou, W. (2020) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc49601.2020.9330833 · Cited by 4
“Moreover, compared to FOC and DTC controllers, FCS-MPC controller has obvious advantages in steady state and dynamic performance [16].”
Zhang, Z. (2023) · Scientific Reports · doi:10.1038/s41598-023-30742-5 · Cited by 3
Shahrbjari, B. H., Ghanbari, M., Ebrahimi, R., & Jannati, M. (2023) · Electrical Engineering · doi:10.1007/s00202-023-01781-y · Cited by 6
Model Predictive-Position Sensorless Control of PMSM with Non-Sinusoidal Back-EMF
Chakkalakkal, S., Vijayan, A. K., & Nahid‐Mobarakeh, B. (2023) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itecasia-pacific59272.2023.10372322 · Cited by 3
“This work uses the finite control set MPC (FCS-MPC) for controlling the PMSM in the stationary reference frame [11]– [13].”
MethodLiu, Z., Tang, T., Houari, A., Machmoum, M., & Benkhoris, M. F. (2021) · Journal of Marine Science and Engineering · doi:10.3390/jmse9060574 · Cited by 4
Xu, L., Ji, D., Tan, Y. Z., Goh, E. W., & Ang, M. H. (2025) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros60139.2025.11246545 · Cited by 2
“Moreover, combining stochastic MPC with health-aware predictive models enhances resilience against anomalies [9], [10], [11].”
Yousefi, B., Ghanbari, M., Ebrahimi, R., & Jannati, M. (2023) · IET Power Electronics · doi:10.1049/pel2.12558 · Cited by 3
Chen, X., Ling, Z., Li, T., Liu, H., Zhou, F., Ouyang, X., Jiang, H., & Yang, B. (2023) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon51785.2023.10311910 · Cited by 2
“However, under the OCF condition, the distribution of voltage vectors in the control set of fault-tolerant FCS-MPCC is sparse and uneven [10], resulting in low accuracy of fault-tolerant control and large ripples of current and torque.”
BackgroundDesign of Test Turntable Based on Fuzzy PID Algorithm and its Error Correction
Li, T., & Zhou, L. (2024) · Scalable Computing Practice and Experience · doi:10.12694/scpe.v25i5.3055 · Cited by 2
Yan, X., Guan, B., & Du, X. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9255263 · Cited by 2
de Oliveira, L. M., Melo, V. F. M. B., da Paz, G. F., Rocha, F. V., & Fabrício, E. L. L. (2021) · Brazilian Power Electronics Conference (COBEP) · doi:10.1109/cobep53665.2021.9684113 · Cited by 2
Guan, B., Zhen, X., Yan, X., & Du, X. (2022) · IET Power Electronics · doi:10.1049/pel2.12331 · Cited by 2
A Modified FOC for FTC of Induction Motor Drives
Yousefi, B., Ghanbari, M., & Ebrahimi, R. (2022) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-022-07484-z · Cited by 3
Numerical Robustness Evaluation of Floating-Point Closed-Loop Control Based on Interval Analysis
Savi, F., Farjudian, A., Buticchi, G., Barater, D., & Franceschini, G. (2023) · Electronics · doi:10.3390/electronics12020390 · Cited by 1
Summary of Model Predictive Control Methods in Motor Drive System
Yang, H., & Wu, H. X. (2021) · IEEE International Conference on Control Science and Systems Engineering (ICCSSE) · doi:10.1109/iccsse52761.2021.9545123 · Cited by 1
Chen, D., Zhao, W., Sun, Y., Zhao, W., Zhang, Z., & Xin, Z. (2024) · IET Power Electronics · doi:10.1049/pel2.12688 · Cited by 1
Fault-Tolerant Control of Standard Three-Phase PMSM Drives Considering Copper Loss
Wang, X., Ren, S., Shen, J., Zhang, Z., Mao, Y., & Wang, Z. (2022) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itecasia-pacific56316.2022.9942202 · Cited by 1
Li, H., Ma, C., & Belie, F. D. (2020) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec48692.2020.9161513
“Generally, the MPC used in the machine drives can be categorized to finite-controlset MPC (FCS-MPC) [1]–[3] and continuous-control-set MPC (CCS-MPC) [4], [5].”
MethodWang, Q., Yu, H., Li, C., Yeoh, S. S., Lang, X., Yang, T., Rivera, M. E., Bozhko, S. V., & Wheeler, P. W. (2020) · doi:10.36227/techrxiv.12815216.v1
Xu, L. J., Liu, H., Liu, L., Zhang, C., Zhang, L., & Du, Y. (2021) · International Symposium on Linear Drives for Industry Applications (LDIA) · doi:10.1109/ldia49489.2021.9505933
“Recently, owing to the excellent optimal state prediction function, the model prediction control (MPC) has received widespread attentions [19].”
BackgroundFCS-MPC Based Fault Tolerant Control for Permanent Magnet Synchronous Machines
Catuogno, G. R., Kiselev, A., Frias, R. G., Kuznietsov, A., García, G. O., & Leidhold, R. (2020) · IEEE Congreso Bienal de Argentina (ARGENCON) · doi:10.1109/argencon49523.2020.9505496
“En este trabajo se propone una estrategia tolerante a fallas de circuito abierto utilizando FCS-MPC para la la implementación del control de corriente a diferencia del realizado en [28] que utiliza la estrategia estudiada para implementar el control de torque.”
BackgroundSelf-citationXu, N., Zhu, Y., Chen, X., & Yang, T. (2021) · Chinese Control Conference (CCC) · doi:10.23919/ccc52363.2021.9549891
“Therefore, a class of fault-tolerant controller is usually proposed to ensure the stability of the system [13-17].”
BackgroundPeng, K., Huang, S., Cao, G., Liu, Y., & Jing, G. (2021) · IEEE International Conference on Predictive Control of Electrical Drives and Power Electronics (PRECEDE) · doi:10.1109/precede51386.2021.9681023
Wang, Q., Yu, H., Li, C., Yeoh, S. S., Lang, X., Yang, T., Rivera, M. E., Bozhko, S. V., & Wheeler, P. W. (2020) · doi:10.36227/techrxiv.12815216
Zhang, Y., Li, Q., Li, S., Kong, D., & Wang, D. (2024) · Lecture notes in electrical engineering · doi:10.1007/978-981-97-0252-7_94
Fault-Tolerant Control of Open-phase Fault For sensorless PMSM Drives
Zhang, Y., Mao, Y., Wang, X., Kong, L., Zhang, T., Duan, Q., & Deng, J. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567745
“Recently, many fault-tolerant control methods for OPF have been published in conventional motor drives [11]-[17], which are realized by using redundant backup circuit [11]-[12], opening motor wingdings [13]-[14], and adding phase number of motor [15]-[17].”
Speed Loop Model Predictive Control Method for PMSM Based on RNN
Wang, X., & Zhang, Y. (2024) · International Conference on Energy Systems and Electrical Power (ICESEP) · doi:10.1109/icesep62218.2024.10652139
“It is mainly divided into continuous control set model predictive control (CCS-MPC) [5] and finite control set model predictive control (FCS-MPC) [6] based on different control actions.”
BackgroundZhu, J., Li, W., Ji, B., Li, L., & Wu, Q. (2024) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.23919/icems60997.2024.10921109
Wang, Z., Zhang, J., Wang, Z., Wang, H., & Bai, Z. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5261595
Open-Winding Fault-Tolerant Three-Vector Current Control Based on Current Ripple Reduction
Huang, H., Lin, X., Zhang, D., Sun, M., & Chen, Z. (2025) · Asia Energy and Electrical Engineering Symposium (AEEES) · doi:10.1109/aeees64634.2025.11019600
Robust LPV Fault Tolerant Tracking Control Using Set-Based Approaches for Autonomous Vehicles
Zhang, S., Ifqir, S., & Puig, V. (2025) · International Conference on Control and Fault-Tolerant Systems (SysTol) · doi:10.1109/systol66549.2025.11267365
“Within the active FTC framework, several reconfigurable control techniques have been adopted, such as adaptive control [9], model predictive control(MPC) [10], feedback control [11], sliding mode control [12], among others.”
Zhai, Y., Ma, W., Xu, B., Xie, Y., Hu, R., Xiao, H., & Zhang, J. (2025) · International Conference on Advanced Electrical and Energy Systems (AEES) · doi:10.1109/aees66649.2025.11332314
Liu, Z. (2021) · theses.fr (ABES) · doi:10.70675/13fc3dfcz95b9z4d7czb141ze86067e11be4 · Cited by 1
Zhang, X. (2022) · theses.fr (ABES) · doi:10.70675/d2280d2cz2547z421bzbc33z8c99545774ab · Cited by 3
Improved dual-loop self-tolerant control of non-phase-shift DTP-PMSM under open-circuit faults
Bai, W., Xu, Z., ZHANG, C., Wang, Y., Ma, Z., & Hua, X. (2026) · Journal of Power Electronics · doi:10.1007/s43236-026-01371-8
Wang, W., Wang, H., & Wu, X. (2026) · IEEE Access · doi:10.1109/access.2026.3727628
Metadata
- Authors
- Kiselev, A., Catuogno, G. R., Kuznietsov, A., & Leidhold, R.
- Affiliations
- Technische Hochschule Mittelhessen (DE)
- Universidad Nacional de Villa Mercedes (AR)
- Otto-von-Guericke-Universität Magdeburg (DE)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2020-06
- Volume
- 67
- Issue
- 6
- Pages
- 4444-4452
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2966061424
- Cited by
- 88
- References
- 21
- Citations by year
- 2026: 2 · 2025: 9 · 2024: 16 · 2023: 13 · 2022: 15 · 2021: 19 · 2020: 13
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Funders
- Mittelhessen University of Applied Sciences, Germany
- National Scientific and Technical Research Council, Argentina
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- finite control set model predictive control, fault-tolerant control, permanent magnet synchronous motor drives, open-phase fault, capacitive divider, fault detection, torque ripple reduction, motor drives
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.