The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Brain waves for automatic biometric-based user recognition
Abstract
Brain signals have been investigated within the medical field for more than a century to study brain diseases like epilepsy, spinal cord injuries, Alzheimer's, Parkinson's, schizophrenia, and stroke among others. They are also used in both brain computer and brain machine interface systems with assistance, rehabilitative, and entertainment applications. Despite the broad interest in clinical applications, the use of brain signals has been only recently investigated by the scientific community as a biometric characteristic to be used in automatic people recognition systems. However, brain signals present some peculiarities, not shared by the most commonly used biometrics, such as face, iris, and fingerprints, with reference to privacy compliance, robustness against spoofing attacks, possibility to perform continuous identification, intrinsic liveness detection, and universality. These peculiarities make the use of brain signals appealing. On the other hand, there are many challenges which need to be properly addressed. The understanding of the level of uniqueness and permanence of brain responses, the design of elicitation protocols, and the invasiveness of the acquisition process are only few of the challenges which need to be tackled. In this paper, we further speculate on those issues, which represent an obstacle toward the deployment of biometric systems based on the analysis of brain activity in real life applications and intend to provide a critical and comprehensive review of state-of-the-art methods for electroencephalogram-based automatic user recognition, also reporting neurophysiological evidences related to the performed claims.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Updating P300: An integrative theory of P3a and P3b
Polich, J. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.019 · Cited by 7,919
The brainweb: phase synchronization and large-scale integration
Varela, F., Lachaux, J.-P., Rodriguez, E., & Martinerie, J. (2001) · Nature Reviews Neuroscience · doi:10.1038/35067550 · Cited by 4,761
Searching for a baseline: Functional imaging and the resting human brain
Gusnard, D. A., & Raichle, M. E. (2001) · Nature Reviews Neuroscience · doi:10.1038/35094500 · Cited by 3,371
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Anterior cerebral asymmetry and the nature of emotion
Davidson, R. J. (1992) · Brain and Cognition · doi:10.1016/0278-2626(92)90065-t · Cited by 1,376
Gamma, alpha, delta, and theta oscillations govern cognitive processes
Başar, E., Başar-Eroglu, C., Karakaş, S., & Schürmann, M. (2001) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(00)00145-8 · Cited by 1,219
EEG differences between eyes-closed and eyes-open resting conditions
Barry, R. J., Clarke, A. R., Johnstone, S. J., Magee, C. A., & Rushby, J. A. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.07.028 · Cited by 1,077
Event-Related Brain Potentials in Man
(1978) · Elsevier eBooks · doi:10.1016/b978-0-12-155150-6.x5001-9 · Cited by 954
EEG alpha map series: brain micro-states by space-oriented adaptive segmentation
Lehmann, D., Ozaki, H., & Pal, I. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90025-3 · Cited by 913
Mu and Beta Rhythm Topographies During Motor Imagery and Actual Movements
McFarland, D. J., Miner, L. A., Vaughan, T. M., & Wolpaw, J. R. (2000) · Brain Topography · doi:10.1023/a:1023437823106 · Cited by 860
Toward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
Handbook of electroencephalography and clinical neurophysiology
Pfurtscheller, G. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90281-x · Cited by 711
How about taking a low‐cost, small, and wireless EEG for a walk?
Debener, S., Minow, F., Emkes, R., Gandras, K., & de Vos, M. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01471.x · Cited by 540
Person Authentication Using Brainwaves (EEG) and Maximum A Posteriori Model Adaptation
Marcel, S., & R. Millan, J. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1012 · Cited by 535
Müller, K.-R., Tangermann, M., Dornhege, G., Krauledat, M., Curio, G., & Blankertz, B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.09.022 · Cited by 474
Harmony, T., Fernández, T., Silva, J., Bernal, J., Díaz-Comas, L., Reyes, A., Marosi, E., Rodríguez, M., & Rodríguez, M. (1996) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(96)00053-0 · Cited by 463
Tomarken, A. J., Davidson, R. J., Wheeler, R. E., & Kinney, L. (1992) · Psychophysiology · doi:10.1111/j.1469-8986.1992.tb02034.x · Cited by 423
Theta band power in the human scalp EEG and the encoding of new information
Klimesch, W., Doppelmayr, M., Russegger, H., & Pachinger, T. (1996) · NeuroReport · doi:10.1097/00001756-199605170-00002 · Cited by 422
COGNITIVE PSYCHOPHYSIOLOGY: THE ENDOGENOUS COMPONENTS OF THE ERP
DONCHIN, E., RITTER, W., & MCCALLUM, W. C. (1978) · Event-Related Brain Potentials in Man · doi:10.1016/b978-0-12-155150-6.50019-5 · Cited by 415
Visual evoked potentials standard (2004)
Odom, J. V., Bach, M., Barber, C., Brigell, M., Marmor, M. F., Tormene, A. P., Holder, G. E., & Vaegan (2004) · Documenta Ophthalmologica · doi:10.1023/b:doop.0000036790.67234.22 · Cited by 394
Vogel, F., Schalt, E., Kr�ger, J., Propping, P., & Lehnert, K. F. (1979) · Human Genetics · doi:10.1007/bf00295569 · Cited by 385
Visual Evoked Potentials Standard
(2006) · Principles and Practice of Clinical Electrophysiology of Vision · doi:10.7551/mitpress/5557.003.0033 · Cited by 358
Functional topography of the human mu rhythm
Kuhlman, W. N. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90107-4 · Cited by 341
Event-Related Brain Potentials: Methods, Theory, and Applications
Fabiani, M., Gratton, G., & Federmeier, K. D. (2009) · Handbook of Psychophysiology · doi:10.1017/cbo9780511546396.004 · Cited by 294
Test-retest reliability of spectral parameters of the EEG
Gasser, T., Bächer, P., & Steinberg, H. (1985) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(85)90005-7 · Cited by 284
Event-related desynchronization in the alpha band and the processing of semantic information
Klimesch, W., Doppelmayr, M., Pachinger, T., & Russegger, H. (1997) · Cognitive Brain Research · doi:10.1016/s0926-6410(97)00018-9 · Cited by 283
Polich, J. (2011) · Oxford Handbooks Online · doi:10.1093/oxfordhb/9780195374148.013.0089 · Cited by 278
Single-trial classification of vowel speech imagery using common spatial patterns
DaSalla, C. S., Kambara, H., Sato, M., & Koike, Y. (2009) · Neural Networks · doi:10.1016/j.neunet.2009.05.008 · Cited by 274
Test-retest reliability in EEG frequency analysis
Salinsky, M. C., Oken, B. S., & Morehead, L. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90203-g · Cited by 274
Biometrics from Brain Electrical Activity: A Machine Learning Approach
Palaniappan, R., & Mandic, D. P. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1013 · Cited by 264
Fernández, T., Harmony, T., Rodríguez, M., Bernal, J., Silva, J., Reyes, A., & Marosi, E. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)00262-j · Cited by 222
Anterior brain electrical asymmetries in response to reward and punishment
Sobotka, S. S., Davidson, R. J., & Senulis, J. A. (1992) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(92)90117-z · Cited by 221
Heritability of human brain functioning as assessed by electroencephalography.
van Beijsterveldt, C. E., Molenaar, P. C. M., de Geus, E. J. C., & Boomsma, D. I. (1996) · PubMed Central · Cited by 219
The genetic basis of the normal human electroencephalogram (EEG)
Vogel, F. (1970) · Humangenetik · doi:10.1007/bf00295509 · Cited by 217
Long-term intra-individual variability of the background EEG in normals
Kondacs, A., & Szabó, M. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00122-4 · Cited by 207
Test–retest reliability of resting EEG spectra validates a statistical signature of persons
Näpflin, M., Wildi, M., & Sarnthein, J. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.07.022 · Cited by 196
Separation of circadian and wake duration-dependent modulation of EEG activation during wakefulness
Cajochen, C., Wyatt, J. K., Czeisler, C. A., & Dijk, D. J. (2002) · Neuroscience · doi:10.1016/s0306-4522(02)00209-9 · Cited by 191
Subject identification from electroencephalogram (EEG) signals during imagined speech
Brigham, K., & Kumar, B. V. K. V. (2010) · IEEE International Conference on Biometrics: Theory, Applications and Systems (BTAS) · doi:10.1109/btas.2010.5634515 · Cited by 184
Test–retest reliability of cognitive EEG
McEvoy, L. K., Smith, M. E., & Gevins, A. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00258-8 · Cited by 184
The reliability of ERP components in the auditory oddball paradigm
SEGALOWITZ, S. J., & BARNES, K. L. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb02068.x · Cited by 181
Visual Spatial Attention Control in an Independent Brain-Computer Interface
Kelly, S. P., Lalor, E. C., Finucane, C., McDarby, G., & Reilly, R. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851510 · Cited by 176
slow Cortical Potentials: Plasticity, Operant Control, and Behavioral Effects
Birbaumer, N. (1999) · The Neuroscientist · doi:10.1177/107385849900500211 · Cited by 163
Two circadian rhythms in the human electroencephalogram during wakefulness
Aeschbach, D., Matthews, J. R., Postolache, T. T., Jackson, M. A., Giesen, H. A., & Wehr, T. A. (1999) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1999.277.6.r1771 · Cited by 163
Gamma coherence and conscious perception
Meador, K. J., Ray, P. G., Echauz, J. R., Loring, D. W., & Vachtsevanos, G. J. (2002) · Neurology · doi:10.1212/wnl.59.6.847 · Cited by 161 · cited 1×
“• Beta 14 − 30Hz: Phase synchrony in Beta frequency band is enhanced for consciously perceived stimuli [17], and detectable mainly from the involved cortical areas, including somatosensory, frontal, parietal and motor regions, depending on the performed task.”
BackgroundPersonality and the EEG: Arousal and emotional arousability
Stenberg, G. (1992) · Personality and Individual Differences · doi:10.1016/0191-8869(92)90025-k · Cited by 153
Brain-computer communication and slow cortical potentials
Hinterberger, T., Schmidt, S., Neumann, N., Mellinger, J., Blankertz, B., Curio, G., & Birbaumer, N. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827067 · Cited by 151
TWO-STAGE BIOMETRIC AUTHENTICATION METHOD USING THOUGHT ACTIVITY BRAIN WAVES
Palaniappan, R. (2008) · International Journal of Neural Systems · doi:10.1142/s0129065708001373 · Cited by 142
Vogel, F., Schalt, E., & Kr�ger, J. (1979) · Human Genetics · doi:10.1007/bf00295570 · Cited by 123
Common and specific genetic influences on EEG power bands delta, theta, alpha, and beta
Zietsch, B. P., Hansen, J., Hansell, N. K., Geffen, G. M., Martin, N. G., & Wright, M. J. (2007) · Biological Psychology · doi:10.1016/j.biopsycho.2007.01.004 · Cited by 107
Method of identifying individuals using VEP signals and neural network
Palaniappan, R. (2004) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:20040003 · Cited by 97
Handbook of Electroencephalography and Clinical Neurophysiology
Roth, B. (1977) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(77)90272-3 · Cited by 88
EEG biometrics for individual recognition in resting state with closed eyes
Rocca, D. L., Campisi, P., & Scarano, G. (2012) · Iris (Roma Tre University) · Cited by 72
Self-citationComputerized recognition of persons by EEG spectral patterns
Stassen, H. H. (1980) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(80)90368-5 · Cited by 69
ID Proof on the Go: Development of a Mobile EEG-Based Biometric Authentication System
Klonovs, J., Petersen, C. K., Olesen, H., & Hammershøj, A. (2013) · IEEE Vehicular Technology Magazine · doi:10.1109/mvt.2012.2234056 · Cited by 69
Kennard, M. A., & Schwartzman, A. E. (1957) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(57)90059-7 · Cited by 66
Test–retest reliability of EEG spectra during a working memory task
Näpflin, M., Wildi, M., & Sarnthein, J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.08.028 · Cited by 59
EEG differences between resting states with eyes open and closed in darkness
Boytsova, J. A., & Danko, S. G. (2010) · Human Physiology · doi:10.1134/s0362119710030199 · Cited by 59
Individual differences in the human electroencephalogram during quiet wakefulness
van Dis, H., Corner, M. A., Dapper, R., Hanewald, G. J. F. P., & Kok, H. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90035-x · Cited by 56
Genetic Influence on the Variance in P3 Amplitude and Latency
Wright, M. J., Hansell, N. K., Geffen, G. M., Geffen, L. B., Smith, G. A., & Martin, N. G. (2001) · Behavior Genetics · doi:10.1023/a:1013393327704 · Cited by 52
Genetic Correlation Between the P300 Event-Related Brain Potential and the EEG Power Spectrum
Anokhin, A. P., van Baal, G. C. M., van Beijsterveldt, C. E. M., de Geus, E. J. C., Grant, J. D., & Boomsma, D. I. (2001) · Behavior Genetics · doi:10.1023/a:1013341310865 · Cited by 51
Circadian and seasonal variability of resting frontal EEG asymmetry
Peterson, C. K., & Harmon‐Jones, E. (2008) · Biological Psychology · doi:10.1016/j.biopsycho.2008.11.002 · Cited by 50
Analysis of effective channel placement for an EEG-based biometric system
Abdullah, M. K., Subari, K. S., Loong, J. L. C., et al. (2010) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2010.5742249 · Cited by 49
Using rapid visually evoked EEG activity for person identification
Das, K., Zhang, S., Giesbrecht, B., & Eckstein, M. P. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334858 · Cited by 47
EEG for Automatic Person Recognition
Campisi, P., Rocca, D. L., & Scarano, G. (2012) · Computer · doi:10.1109/mc.2012.233 · Cited by 42
Self-citationKnyazev, G. G. (2010) · The Open Neuroimaging Journal · doi:10.2174/1874440001004010114 · Cited by 38
O'Donoghue, T., Morris, D. W., Fahey, C., Costa, A. D. S., Foxe, J. J., Hoerold, D., Tropea, D., Gill, M., Corvin, A. P., & Donohoe, G. J. (2011) · Human Brain Mapping · doi:10.1002/hbm.21281 · Cited by 25
Johnson, L. C., & Ulett, G. A. (1959) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(59)90078-1 · Cited by 25
Electroencephalographic individual differences and their constancy: II. During waking.
Henry, C. E. (1941) · Journal of Experimental Psychology · doi:10.1037/h0057822 · Cited by 23
Electroencephalographic individual differences and their constancy: I. During sleep.
Henry, C. E. (1941) · Journal of Experimental Psychology · doi:10.1037/h0061342 · Cited by 23
Carmena, J. M. (2012) · IEEE Spectrum · doi:10.1109/mspec.2012.6156860 · Cited by 21
Inter-session stability of human alpha rhythm densities
Lynch, J. J., Paskewitz, D. A., & Orne, M. T. (1974) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(74)90211-9 · Cited by 16
Event-Related Potentials of the Cerebral Cortex
Bressler, S. L. (2010) · Neuromethods · doi:10.1007/978-1-60327-202-5_7 · Cited by 8
Cited by
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Khosla, A., Khandnor, P., & Chand, T. (2020) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2020.02.002 · Cited by 267
Human Brain Distinctiveness Based on EEG Spectral Coherence Connectivity
Rocca, D. L., Campisi, P., Vegso, B., Cserti, P., Kozmann, G., Babiloni, F., & Fallani, F. D. V. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2317881 · Cited by 256
Self-citation
Metadata
- Authors
- Campisi, P., & La Rocca, D.
- Venue
- IEEE Transactions on Information Forensics and Security
- Published
- 2014-05
- Volume
- 9
- Issue
- 5
- Pages
- 782-800
- ISSN
- 1556-6013 (ISSN-L)
- 1556-6021
- OpenAlex
- W2011584637
- Cited by
- 264
- References
- 74
- FWCI
- 28.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.