The Thyristor Electronic Transformer: a Power Converter Using a High-Frequency Link
The DOI matches its Crossref record.
Abstract
The electronic transformer is a device which behaves in the same manner as a conventional power transformer in that it steps voltage levels up or down while providing isolation and can accommodate load current of any power factor. It contains thyristor power switches which convert the low-frequency (dc to 400-Hz) voltage wave to a high-frequency (in the order of 10 000 Hz) wave. A comparatively small magnetic transformer then provides the voltage level transformation and isolation functions. Similar thyristor power switches then reconstruct the original low-frequency wave at the desired output voltage level. This device can incorporate additional features not found in a conventional transformer, such as current limiting and current interruption. The theory of operation is presented and confirmed by experimental data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applicability of solid-state transformers in today's and future distribution grids
Huber, J. E., & Kolar, J. W. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2738610 · Cited by 506
“Even though an “electronic transformer” had first been proposed already in the early 1970s [5], the concept was”
BackgroundAnalysis and Design of High-Frequency Isolated Dual-Bridge Series Resonant DC/DC Converter
Li, X., & Bhat, A. K. S. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2034662 · Cited by 493
“With all twoquadrant switches replaced with four-quadrant switches [23], the converter could be controlled as an ac/ac electronic trans-”
BackgroundMethodSolid-State Transformers: On the Origins and Evolution of Key Concepts
Huber, J. E., & Kolar, J. W. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2588878 · Cited by 449
“To facilitate the commutation of these thyristors, a shaping of the transformer current into sinusoidal pulses with a natural zero-crossing by means of adding a series resonant capacitor [Figure 2(b)] was additionally proposed by McMurray, also in 1968 [22], [24] (and, almost simultaneously, in a similar fashion by Sc…”
MethodHannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“This type is operating in direct DC-DC or AC-AC power conversion stages with better efficiency and higher reliability [26]–[28].”
BackgroundPower Electronic Transformer-Based Railway Traction Systems: Challenges and Opportunities
Feng, J., Chu, W. Q., Zhang, Z., & Zhu, Z. Q. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2685464 · Cited by 229
Overview of Silicon Carbide Technology: Device, Converter, System, and Application
Wang, F. (., & Zhang, Z. (2016) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2016.00003 · Cited by 204
“2) High Performance Solid-state Transformer Another attractive application of SiC devices is in the replacement of bulky line-frequency 50 or 60 Hz transformers with solid-state alternatives based on high frequency link transformers especially in MV applications, such as distribution grid, shipboard power systems, hig…”
BackgroundOptimum Number of Cascaded Cells for High-Power Medium-Voltage AC–DC Converters
Huber, J. E., & Kolar, J. W. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2605702 · Cited by 191
“ac link for isolation purposes dates back to 1970 [3], [4].”
BackgroundZhu, Q., Wang, L., Huang, A. Q., Booth, K., & Zhang, L. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2829174 · Cited by 155
Dong, D., Agamy, M., Bebic, J. Z., Chen, Q., & Mandrusiak, G. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2896046 · Cited by 154
Advances in Power Conversion and Drives for Shipboard Systems
Wang, F., Zhang, Z., Ericsen, T., Raju, R., Burgos, R., & Boroyevich, D. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2495331 · Cited by 135
Zhu, Q., Wang, L., Chen, D., Zhang, L., & Huang, A. Q. (2017) · 2017 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8095938 · Cited by 32
“The first direct AC-AC topology is proposed in 1971 based on thyristors [5].”
BackgroundMethodFull-ZVS modulation for all-SiC ISOP-type isolated front end (IFE) solid-state transformer
Huber, J. E., Rothmund, D., Wang, L., & Kolar, J. W. (2016) · 2016 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855128 · Cited by 31
Cascaded multilevel SST medium voltage converter for solar applications
Foureaux, N. C., Filho, B. J. C., & Brito, J. A. S. (2015) · 2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2015.7167874 · Cited by 13
“Developed originally for AC-AC applications with the same input and output frequencies [5-7], the Solid State Transformer – SST – is based on a high-frequency AC link and a high-frequency transformer.”
BackgroundDevelopment of a Power and Voltage Control Scheme for Multi-Port Solid State Transformers
Khayamy, M., Nasiri, A., & Altin, N. (2018) · 2018 7th International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2018.8567001 · Cited by 7
“Triangular current modulation strategy which uses the duty cycle to control the power transferred among the bridges is also applied to the four-port MPSST [13], [14].”
MethodLi, C., Chen, T., Su, L., Zhang, Z., & Zheng, Z. (2025) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2024.3497412 · Cited by 7
Metadata
- Authors
- McMurray, W.
- Venue
- IEEE Transactions on Industry and General Applications
- Published
- 1971-07
- Volume
- IGA-7
- Issue
- 4
- Pages
- 451-457
- ISSN
- 0018-943X (ISSN-L)
- OpenAlex
- W2087073805
- Cited by
- 84
- References
- 0
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.