This paper presents an implementation of an IEC 61850-based real-time co-simulation platform for verification of the performance of a volt-VAR optimization (VVO) engine for smart distribution networks. The proposed VVO engine is able to minimize grid loss, volt-VAR control asset operational costs, and conservation voltage reduction operational costs through its comprehensive objective functions, weighted by fuzzification using advanced metering infrastructure (AMI) data. The optimization engine receives the AMI data stream through measurement aggregators. Moreover, it sends control commands to volt-VAR control components modeled in real-time digital simulator (RTDS) through DNP.3 protocol. To check the performance and the precision of proposed VVO, a fault scenario is imposed upon the system. IEC 61850 GOOSE messages are generated and sent to change the status of specified breakers, while the VVO engine receives system reconfiguration commands via IEC61850 Manufacturing Message Specification (MMS) protocol. The results of the study on 33-node feeder showed adequate performance of proposed VVO in grid operating scenarios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiagent-Based Distribution Automation Solution for Self-Healing Grids
Eriksson, M., Armendariz, M., Vasilenko, O. O., Saleem, A., & Nordström, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2387098 · Cited by 149 · cited 1×
“Several works have studied different IEC 61850 smart grid and distribution network applications such as interoperability and interchange-ability [16], multi agent systems [7], [17], and EMS [18].”
Background
Cited by
A Review of IEC 62351 Security Mechanisms for IEC 61850 Message Exchanges
Hussain, S. M. S., Ustun, T. S., & Kalam, A. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2019.2956734 · Cited by 185
OPF-Based CVR Operation in PV-Rich MV-LV Distribution Networks
Gutierrez-Lagos, L., & Ochoa, L. F. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2894795 · Cited by 67
León, H., Montez, C., Valle, O., & Vasques, F. (2019) · Energies · doi:10.3390/en12122272 · Cited by 35
“Other works, as in [24], used the so-called Real-Time Digital Simulator (RTDS) to assess the behavior of SAS close to real situations.”
Method
Metadata
- Authors
- Manbachi, M., Sadu, A., Farhangi, H., Monti, A., Palizban, A., Ponci, F., & Arzanpour, S.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2016-08
- Volume
- 12
- Issue
- 4
- Pages
- 1392-1402
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2397915956
- Cited by
- 92
- References
- 1
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Co-Simulation Platform for Smart Grid Volt-VAR Optimization Using IEC 61850. https://app.cochat.ai/papers/10.1109/tii.2016.2569586
- The paper
- Manbachi, M., Sadu, A., Farhangi, H., Monti, A., Palizban, A., Ponci, F., & Arzanpour, S. (2016). Real-Time Co-Simulation Platform for Smart Grid Volt-VAR Optimization Using IEC 61850. IEEE Transactions on Industrial Informatics. https://doi.org/10.1109/tii.2016.2569586
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.